Study of Short-Circuit Currents Around Dĕtmarovice Power Station

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권3호
    • /
    • pp.117-124
    • /
    • 2014
  • The calculation of short-circuit currents is important for power systems operation and restoration, and for determining the means to protect human lives and properties. In this paper, a part of a power system network, around the D$\breve{e}$tmarovice power station in Czech Republic, was simulated by the well known program EMTP-ATPDraw (Electromagnetic Transients Program-Alternative Transient Program), and short-circuit currents and voltages were calculated at different points in the electric network and presented as a time function by the PlotXY program. Calculations were done just for phase-to-ground, and for the three-phase short-circuit at the Kun$\check{c}$ice substation. The results were important for determining the characteristics of the equipment required to withstand or break the short-circuit current; for this reason, the calculations were repeated using earth-fault resistances only for the case of busbar KUN shown in Figs. 5 and 6.

단락시험에서 후비보호차단기와 투입스위치의 중요 역할 (The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test)

  • 김선구;김선호;김원만;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

영구자석 동기모터 진동 및 과전류 저감을 위한 능동단락회로 제어 기법 (Active Short Circuit Control Method to Reduce Overcurrent and Oscillation Current in PMSM)

  • 최종원;김윤재
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.339-347
    • /
    • 2022
  • This study proposes the mitigation method for overcurrent and oscillation motor current in an active short-circuit operation. This operation is attracting attention as the safe state of electric vehicle traction inverters. However, the active short-circuit operation generates oscillation and overcurrent of motor currents during a transient state. The proposed method uses two different safe states in PMSM, such as active short circuit and freewheeling. The active short circuit is used for safe state in a steady state. To reduce the overshoot and oscillation, a freewheeling state is injected between active short-circuit operation by comparing the motor phase current with an analytically calculated steady-state motor current. Freewheeling state is only used in a transient state. The performance is demonstrated through simulations and experimental results. The peak current of the motor was reduced from 52 A to 40 A, and oscillation time was reduced.

KERI 합성투입시험회로의 해석적 고찰 (Analytical Examination of KERI Synthetic Short-circuit Current Making Test Circuit)

  • 이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 2003
  • In the present IEC 60427(2000), reduced applied voltage can be used for synthetic short-circuit making current tests if the maximum pre-arcing time of the test circuit breaker is less than $1/{\omega}$. But in the near future IEC, only the making tests with full test voltage shall be allowed. To meet this trend, KERI is preparing synthetic making test facilities using step-up transformer, ITMC and plasma making switch. This paper presents analytical characteristics of KERI's synthetic short-circuit making test circuits. The results of this paper can be useful for effective and adequate tests.

  • PDF

GMAW 공정에서 아크 안정성의 실시간 측정 (Real-time estimation of arc stability in GMAW process)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • 제8권1호
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

옥내배선 길이에 따른 단락 특성의 실험적 연구 (An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length)

  • 송재용;김진표;조영진;최돈묵;오부열;길경석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

합성단락시험용 재점호장치 (Reignition system for synthetic short-circuit test)

  • 박승처;김맹현;강영식;신영준;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1856-1858
    • /
    • 2000
  • This paper describes the principles of reignition system which has newly been developed and used as KERI's high power testing facilities. Synthetic short-circuit testing method is generally adopted to perform the short-circuit test of the ultra high-voltage circuit breakers, which consists of two separated sources such as the current source from short-circuit generator and the voltage source from charged energy in capacitor. And, in case of synthetic short-circuit test, it will be necessary to use the reignition system in order to extending the arcing time of the circuit breaker and provide the arc energy equivalent to the direct testing method.

  • PDF

단락시험 회로의 시정수 조정에 의한 투입전류 제한법 (Limiting method of short-circuit making current by controlling the time constant of dc component)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.466-468
    • /
    • 2002
  • In order to newly define and specify the performance and the testing method of the high-voltage circuit breaker, IEC 62271-100 was published in May, 2001 and took place of IEC 60056 which had been used since 1987. This new standard intensifies the requirement and the test method of the circuit breaker and also domestic manufacturer makes progress the new product development. And, KERI also goes on the build-up project of short-circuit testing facilities for fulfilling the testing method requirements in new IEC 62271-100. This paper introduce the limiting method of short-circuit making current by controlling the time constant of dc component.

  • PDF

GMA용접 시스템의 동적 거동에 대한 해석 (Analysis of Dynamic Behavior in GMAW System)

  • 이재영;최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • 제18권5호
    • /
    • pp.41-48
    • /
    • 2000
  • Dynamic behaviors of the GMAW system are simulated using the short-circuit transfer model and the characteristic equations fir the power supply, wire system and arc. The conventional wire equation, which relates the rate change of the wire extension to the wire feed rate and melting rate, is modified to include effects of the molten drop attached at the wire tip. The modified wire equation describes behaviors of the GMAW system more precisely and provides information about the initial bridge volume for short-circuit transfer. The proposed short-circuit model predicts the variation of parameters such as the current, voltage, short-circuit frequency and time considering the effects of the surface tension and electromagnetic force due to current. The calculated results are in broad agreements with the experimental results under the argon shielding condition.

  • PDF