• Title/Summary/Keyword: Shock resistance

Search Result 436, Processing Time 0.023 seconds

An Efficient FTL Algorithm for Flash Memory (플래시 메모리를 위한 효율적인 사상 알고리즘)

  • Chung Tae-Sun;Park Hyung-Seok
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.9
    • /
    • pp.483-490
    • /
    • 2005
  • Recently, flash memory is widely used in embedded applications since it has strong points: non-volatility, fast access speed, shock resistance, and low power consumption. However, due to its hardware characteristics, it requires a software layer called FTL(flash translation layer). The main functionality of FTL is to convert logical addresses from the host to physical addresses of flash memory We present a new FTL algorithm called STAFF(State Transition Applied Fast Flash Translation Layer). Compared to the previous FTL algorithms, STAFF shows five times higher performance than basic block mapping scheme and requires less memory. We provide performance results based on our implementation of STAFF and previous FTL algorithms.

EMC/LVD Compatibility Evaluation of ITER AC/DC Converter Subrack by EN 61000 and IEC 61010 (ITER AC/DC Converter 서브랙의 EN 61000 및 IEC 61010에 의한 EMC/LVD 시험평가)

  • Shin, Hyun-Kook;Oh, Jong-Seok;Song, In-Ho;Suh, Jae-Hak;Choi, Jung-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.222-226
    • /
    • 2021
  • To comply with CE marking requirements, the electromagnetic compatibility (EMC) and low-voltage directive (LVD) tests are conducted on the sub-racks of International Thermonuclear Experimental Reactor (ITER) AC/DC converters and bypass switches. The EMC tests consist of a series of tests, including the electromagnetic interference test, the electromagnetic field immunity test, and the rapid transient burst immunity test. In the LVD test, the electric shock protection test, the xcessive temperature limit and heat resistance of equipment tests, and the fire spread prevention test are performed. This work presents and reviews the European Directive for EMC/LVD and introduces the methods of EMC and LVD tests for the sub-racks of AC/DC converters and bypass switches. It also evaluates the test method and results to meet the European Directive requirements for CE marking. The sub-racks of ITER AC/DC converters and bypass switches successfully pass the EMC and LVD tests.

Thermodynamic analysis on the chemical vapor deposition process of Ta-C-H-Cl system

  • Kim, Hyun-Mi;Shim, Kwang Bo;Lee, Jung-Min;Lee, Hyung-Ik;Choi, Kyoon
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.6
    • /
    • pp.519-524
    • /
    • 2018
  • Carbon/carbon composites (C/C) have been widely studied in the aerospace field because of their excellent thermal shock resistance and specific strength at high temperature. However, they have the problems that is easily oxidized and deteriorated under atmospheric environment. In order to overcome these shortcomings, the CVD coating of ultra-high-temperature ceramics to C/C has become an important technical issue. In this study, thermodynamic calculations were performed to TaC CVD coating on C/C by FactSage 6.2 program. The Ta-C phase diagrams were constructed with the results of thermodynamic calculations in the Ta-C-H-Cl system. Based on the Ta-C phase diagram, the experimental conditions were designed to confirm the deposition of various phases such as TaC single phase, TaC + C and $TaC+Ta_2C$ by varying the composition of Ta/C ratio. The deposited films were found to be in good agreement with the predicted phases.

Simulation of Dynamic Characteristics of a Trigenerative Climate Control System Based On Peltier Thermoelectric Modules

  • Vasilyev, G.S.;Kuzichkin, O.R.;Surzhik, D.I.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.252-257
    • /
    • 2021
  • The application of the principle of trigeneration allows to simultaneously provide electricity to power electronic devices, as well as heat and cold to create the necessary microclimate of the premises and increase efficiency compared to separate cooling and heating systems. The use of Peltier thermoelectric modules (TEM) as part of trigenerative systems allows for smooth and precise control of the temperature regime, high manufacturability and reliability due to the absence of moving parts, resistance to shock and vibration, and small weight and size parameters of the system. One of the promising areas of improvement of trigenerative systems is their modeling and optimization based on the automatic control theory. A block diagram and functional model of an energy-saving trigenerative climate control system based on Peltier modules are developed, and the transfer functions of an open and closed system are obtained. The simulation of the transient characteristics of the system with varying parameters of the components is performed. The directions for improving the quality of transients in the climate control system are determined, as well as the prospects of the proposed methodology for modeling and analyzing control systems operating in substantially nonlinear modes.

Thermal and mechanical properties of C/SiC composites fabricated by liquid silicon infiltration with nitric acid surface-treated carbon fibers

  • Choi, Jae Hyung;Kim, Seyoung;Kim, Soo-hyun;Han, In-sub;Seong, Young-hoon;Bang, Hyung Joon
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.1
    • /
    • pp.48-53
    • /
    • 2019
  • Carbon fiber reinforced SiC composites (C/SiC) have high-temperature stability and excellent thermal shock resistance, and are currently being applied in extreme environments, for example, as aerospace propulsion parts or in high-performance brake systems. However, their low thermal conductivity, compared to metallic materials, are an obstacle to energy efficiency improvements via utilization of regenerative cooling systems. In order to solve this problem, the present study investigated the bonding strength between carbon fiber and matrix material within ceramic matrix composite (CMC) materials, demonstrating the relation between the microstructure and bonding, and showing that the mechanical properties and thermal conductivity may be improved by treatment of the carbon fibers. When fiber surface was treated with a nitric acid solution, the observed segment crack areas within the subsequently generated CMC increased from 6 to 10%; moreover, it was possible to enhance the thermal conductivity from 10.5 to 14 W/m·K, via the same approach. However, fiber surface treatment tends to cause mechanical damage of the final composite material by fiber etching.

LED Delamination Evaluating Method by Thermal Shock Test (열충격시험을 통한 LED 박리 평가법에 관한 연구)

  • Jang, In-Hyeok;Han, Ji-Hoon;Ko, Min-ji;Lee, Young-Joo;Lim, Hong-Woo
    • Journal of Advanced Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.121-124
    • /
    • 2013
  • This paper proposed a new concept of estimating method for LED(light-emitting diode) delamination with high accuracy. Usually, The LED is composed several materials which are LED chips, gold wire, phosphor, epoxy resin, adhesive, reflector and lead frame. These different materials are usually delaminated in a trouble conditions which are huge temperature difference, hot and humid or mechanical shocked. When the components are delaminated, a luminance will be lost, moisture be absorbed easily and a thermal resistance be increased attendantly. As a conventional method to estimate a delamination of LEDs, a solution immersing method is usually used in a field of LED manufacturing companies or researching institutes. This method has an advantage of simplicity but it is only shown that the existence of delamination or not. In this paper, we have proposed an estimating method for LEDs delamination using the polishing and the electron microscope. New proposed method has shown the result of confirming delamination without destruction and enabled quantitative analysis for LED delamination.

Effect of Ground Boundary Condition on Evaluation of Blast Resistance Performance of Precast Arch Structures (지반경계조건이 프리캐스트 아치구조물의 폭발저항성능 평가에 미치는 영향)

  • Lee, Jungwhee;Choi, Keunki;Kim, Dongseok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.5
    • /
    • pp.287-296
    • /
    • 2019
  • In this study, the effect of ground boundary conditions on the evaluation of blast resistance performance of precast arch structures was evaluated by a numerical analysis method. Two types of boundary conditions, namely, fixed boundary conditions and a perfectly matched layer (PML) were applied to numerical models. Blast loads that were much higher than the design load of the target structure were applied to compare the effects of the boundary conditions. The distribution and path of the ground explosion pressure, structural displacement, fracture of concrete, stress of concrete, and reinforcing bars were compared according to the ground boundary condition settings. As a result, the reflecting pressure shock wave at the ground boundaries could be effectively eliminated using PML elements; furthermore, the displacement of the foundation was reduced. However, no distinct difference could be observed in the overall structural behavior including the fracture and stress of the concrete and rebar. Therefore, when blast simulations are performed in the design of protective structures, it is rational to apply the fixed boundary condition on the ground boundaries as conservative design results can be achieved with relatively short computation times.

Clinical Characteristics of Pneumococcal Bacteremia in Adults : The Effect of Penicillin Resistance on the Mortality of Patients with Pneumococcal Bacteremia (폐렴구균 균혈증에서 폐렴구균의 페니실린 내성 여부가 사망률에 미치는 영향)

  • HwangBo, Bin;Yoon, Ho-Il;Lee, Sang-Min;Choi, Seung-Ho;Park, Gye-Young;Yoo, Chul-Gyu;Lee, Choon-Taek;Kim, Young-Whan;Han, Sung-Koo;Min, Kyung-Up;Kim, You-Young;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.184-194
    • /
    • 1999
  • Backgrounds : The advent of penicillin has led to the marked reduction in the mortality from pneumococcal bacteremia, however, the mortality is still relatively high in this post-antibiotic era. Actually the prevalence of infection due to penicillin-resistant penumococci is increasing worldwide, and it is especially high in Korea due to irrelevant use of antibiotics. So, the high mortality of pneumococcal sepsis might be related to the emergence of penicillin-resistant strains, however, many other antibiotics, which eradicate pneumococci effectively, are available in these days. This has led us to suspect the role of penicillin-resistance in the high mortality rate. In this study, we evaluated the effect of penicillin resistance on the mortality of patients with penumococcal bacte remia. Methods: The study population consisted of 50 adult patients with penumococcal bacteremia who were admitted between Jan, 1990 and July, 1997. Medical records were analyzed retrospectively. Results: Most of the patients (96%) had underlying diseases. The most common local disease associated with pneumococcal bacteremia was pneumonia (42%), which was followed by spontaneous bacterial peritonitis (14%), cholangitis (10%), meningitis (8%), liver abscess (4%), pharyngotonsillitis (4%), sinusitis (2%) and cellulitis (2%). While the overall case-fatality rate in this study was 24%, it was higher when peumococcal bacteremia was associated with pneumonia (42%) or meningitis (50%). The rate of penicillin resistance was 40%, which was increased rapidly from 1991. The rate of penicillin resistance was significantly higher in patients with the history of recent antibiotics use and hospitalization within 3 months respectively. The clinical manifestations, that is, age, severity of underlying diseases, nosocomial infection, associated local diseases, and the presence of shock or acute renal failure were not statistically different between the patients with penicillin-resistant and -sensitive pneumococcal bacteremia. The mortality of patients infected with penicillin-resistant pneumococci was not statistically different from those with penicillin-sensitive pneumococcal bacteremia. Conclusion: Penicillin resistance is not associated with high mortality in adult patients with pneumococcal bacteremia. As the overall mortality is high, active penumococcal vaccination is recommended in patients with high risk of infection.

  • PDF

The Effect of Cold Shock on Function and Morphology of Dog Epididymal Spermatozoa (개에서 cold shock이 정소상체유래의 정자의 기능과 형태에 미치는 영향)

  • Yu Il-jeoung
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.329-335
    • /
    • 2004
  • Dog spermatozoa were recovered from the caudae epididymides of 23 domestic dogs which were 11 pure breed and 12 mix-breed dogs ranging in age from 0.6 to 3 years. The experimental designs were as follows: 1) the effect of chilling to 0. 10 or 37$^{\circ}C$. 2) the kinetics of chilling injury at 0 or 4$^{\circ}C$, and 3) the effect of sugars at $0^{\circ}C$. Viable spermatozoa were recovered by percoll gradient separation and adjusted to 5${\times}$10$^{7}$ spermatozoa/ml. In experiment 1, spermatozoa were diluted with 0.33 M glucose supplemented with 3% BSA (G-BSA) at 1:2 dilution. Spermatozoa were loaded into straws and exposed at 0, 10 or 37$^{\circ}C$ for 30 min. In experiment 2, spermatozoa were prepared as the experiment 1 and exposed for 0.5, 5, 15, or 30 min at 0 or 4$^{\circ}C$. In experiment 3, spermatozoa were diluted with different sugars (0.33 M galactose, glucose, fructose, mannitol, lactose, sucrose, raffinose) and cooled to $0^{\circ}C$ for 30 min. Sperm membrane integrity, motility and acrosome integrity were assayed after rewarming at 37$^{\circ}C$ for 5 min. Sperm motility and membrane integrity abruptly decreased with decreasing temperature but acrosome integrity gradually decreased (P<0.05). Sperm motility was more sensitive to cold shock than membrane integrity and acrosome integrity. Spermatozoa cooled to $0^{\circ}C$ were more damaged than those at 4$^{\circ}C$. Sperm motility was not different among exposed times at both. 0 and 4$^{\circ}C$. However, membrane integrity of spermatozoa exposed for 30 min at both 0 and 4$^{\circ}C$ was significantly lower (P<0.05). Spermatozoa diluted in 0.33 M fructose or galactose showed lower motility and higher morphological abnormality with coiled tail at $0^{\circ}C$. These sperm characteristics were strongly related. These results indicate that dog epididymal spermatozoa are relatively sensitive to rapid cooling and higher morphological abnormality at $0^{\circ}C$ was shown in spermatozoa diluted in fructose and galactose.

Study on Improvement of Mechanical Property, Oxidation and Erosion Resistance of SiC Matrix Ceramic Composites Reinforced by Hybrid Fabric Composed of SiC and Carbon Fiber (탄화규소섬유와 탄소섬유 하이브리드 직물을 강화재로 한 SiC 매트릭스 세라믹복합재의 기계적물성, 산화 및 삭마 저항성 개선 연구)

  • Yoon, Byungil;Kim, Myeongju;Kim, Jaesung;Kwon, Hyangjoo;Youn, Sungtae;Kim, Jungil
    • Composites Research
    • /
    • v.32 no.3
    • /
    • pp.148-157
    • /
    • 2019
  • In this study, $C_f/SiC$, $SiC_f/SiC$ and $C_f-SiC_f/SiC$ ceramic composites reinforcing carbon fiber, SiC fiber and hybrid fiber were fabricated by hybrid TGCVI and PIP process. After the thermal shock cycle, 3-point bending and Oxy-Acetylene torch test, their mechanical behavior, oxidation and erosion resistance were evaluated. The $C_f/SiC$ composite showed a decrease in mechanical property along with increasing temperature, a pseudo-ductile fracture mode and a large quantity of erosion. The $SiC_f/SiC$ composite exhibited stronger mechanical property and lower erosion rate compared to the $C_f/SiC$, but brittle fracture mode. On the other hand, hybrid type of $C_f-SiC_f/SiC$ composite gave the best mechanical property, more ductile failure mode than the $SiC_f/SiC$, and lower erosion rate than the $C_f/SiC$. During the Oxy-Acetylene torch test, the $SiO_2$ formed by reaction of the SiC matrix with oxygen prevented further oxidation or erosion of the fibers for $C_f-SiC_f/SiC$ and $SiC_f/SiC$ composites particularly. In conclusion, if a hybrid composite with low porosity is prepared, this material is expected to have high applicability as a high temperature thermo-structural composite under high temperature oxidation atmosphere by improving low mechanical property due to the oxidation of $C_f/SiC$ and brittle fracture mode of $SiC_f/SiC$ composite.