• Title/Summary/Keyword: Ship's ballast

Search Result 76, Processing Time 0.019 seconds

Prediction Method of the BOG for the Membrane Type LNGC in Middle East Route (중동항로 취항 멤브레인형 LNGC의 BOG 예측에 관한 연구)

  • 장은규;정연철
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.343-350
    • /
    • 2004
  • LNGC suffers a great heat inflow during navigation and this heat inflow inevitably boils off the LNG. The boiled off gas(BOG) is normally consumed as a fuel for ship's engine. The boiled off LNG means a loss of cargo during transportation from the viewpoint of shipper. Therefore, a contract between shipper and ship operator is made on the limit of boiled off rate(BOR) under 0.15 %/day based on laden voyage. This contract on BOR limit requires that ship's officer has a correct knowledge on BOR for his ship. But, in most cases ship is operated based on only officer's experiences. In this study, author presented a simple model to predict the boiled off gas(BOG) during navigation based on the existing precision heat exchange design technology about the heat distribution on the hull and heat inflow from outside through the hull. The BOG is calculated for ballast and laden voyage based on the actual weather conditions and verified by comparing with the measured BOG for the study ship. The study ship is a membrane type LNGC which is now servicing in Middle east route. Thus, the BOG prediction method which is presented in this study is expected to be used for an useful tool to manage the BOG in now servicing LNGC.

  • PDF

Prediction Method of the BOG for the Membrane Type LNGC in Middle East Route (중 항로 취항 멤브레인형 LNGC의 BOG 예측에 관한 연구)

  • Jang, Eun-Kyu;Jung, Yun-Chul
    • Journal of Navigation and Port Research
    • /
    • v.28 no.5
    • /
    • pp.365-372
    • /
    • 2004
  • LNGC suffers a great heat inflow during navigation and this heat inflow inevitably boils off the LNG. The boiled off gas(BOG) is normally consumed as a fuel for ship's engine. The boiled off LNG means a loss of cargo during transportation in the viewpoint of shipper. Therefore, a contract between shipper and ship operator is made for the limitation of BOR under 0.15 %/day based on laden voyage. This contract on BOR limit requires that ship's officer has a correct knowledge on BOR for his ship. nut, in most cases ship IS operated based on only officer's experiences. In this study, author presented a simple model to predict the BOG during navigation based on the existing precision heat exchange design technology about the heat distribution on the hull and heat inflow from outside through the hull. The BOG is calculated for ballast and laden voyage based on the actual weather conditions and verified by comparing with the measured BOG for the study ship. The study ship is a membrane type LNGC which is now servicing in Middle east route. Thus, the BOG prediction method which is presented in this study is expected to be used for an useful tool to manage the BOG in now servicing LNGC.

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Technical Treatment on Foreign Invasive Marine Species of Living-things in ship′s Ballast-water (선박안정수의 해양외래침입생물체 처리 기술)

  • 소대화;장지도
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1563-1568
    • /
    • 2003
  • The introduction of invasive marine species of living things into new environments by ship's ballast water, attached to ships' hulls and via other vectors has been identified as one of the four greatest threats to the world's oceans by Global Environment Facility(GEF). Making use of the new technology of alpha-AL$_2$O$_3$ dielectric barrier layer, the strong electric-field gas discharge was introduced and obtained between micro-gap electrodes at high pressure (∼105㎩) of $O_2$ in air and $H_2O$ in seawater. The mixed air with $H_2O$ could be ionized and dissociated into large numbers of activated particles of OH, $O_2$+, O(1D), HO$_2$ and so on, and then dissolved into the ballast water to form dissolved hydroxyl radical with the concentration of ∼20mg/L. Therefore, the invasive marine species was treated effectively through the hydroxyl radical dissolved pipeline of ballast water by strong electric -field discharge.

Development of sampling device for monitoring micro-organisms in treated ballast water (밸러스트 처리수 미생물 모니터링을 위한 Sampling Device 개발)

  • Park, Sung-Jin;Kim, Ki-Wook;Yoon, Seung-Je;Cho, Dong-Yeon;Kim, Sang-Yong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.312-312
    • /
    • 2011
  • All ship's ballast water should be inspected by administration after enter into force IMO BWM Convention. The purpose of the sampling device is to concentrate large amount of samples and to improve return rate of samples. It is composed of Concentration and Rinsing Part and optimized by the variety of tests. it is fully automated and therefore efficiently operated in ships.

  • PDF

Trend Analysis and Diagnosis for BWTS Remote Monitoring (BWTS 원격 모니터링을 위한 트렌드 분석 및 진단)

  • Choi, Wook-Jin;Kim, Chin-Hoon;Choi, Hwi-Min;Lee, Kwang-Seob;Choi, Woo-Jin;Kim, Joo-Man
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.3
    • /
    • pp.127-135
    • /
    • 2014
  • On lot of ships, Ballast Water Treatment Systems(BWTS) are in use, or the newly built ship should be mandatory installation by 2017. It is IMO(International Maritime Organization) regulations. Because the vessel is in long distance, It is managed this system only in the vessel and it may occur considerable cost of maintenance when a problem arises from BWTS. We describe in this paper how to monitor treated ballast water to make sure the ballast water and BWTS on a ship is in proper condition, but before the port entrance. In addition, analysing and forecasting trend signal to prevent failure. Also we can expect reduce the cost of BWTS maintenance. We can monitor the sensor data value's change which collected through satellite from BWTS. And we can observate the ballasting and de-ballasting state of the vessel easily.

Technical Analysis on Existing Ship's Economical Operation (운항선 중심의 선박 경제운항 관리의 기술적 분석)

  • Kang, Nam-seon;Kim, Yong-dae;Yoon, Hyeon-kyu;Byeon, Sang-su
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.519-527
    • /
    • 2016
  • The present study is concept research on the operation cost management of shipping firms, especially considering technology for economical ship operation of existing ships in units of voyage. The factors that influence economical ship operation management were identified by analyzing the current status of the shipping industry, the development of economical ship operation technologies, technological requirements, and the cost factors of ship operation. Economical operation of existing ships, especially, the economical operation of the units of each voyage, may minimize fuel cost and port charges. This requires low-load streaming cruise control, ballast control, optimal trim, optimal routing, terminal work efficiency improvement, and ship energy management. Optimal routing and terminal work efficiency improvement manage the time saved. To determine the low-load streaming, cruise control, ballast control, optimal trim and ship energy management are meeting the recommendations.

The Effect of Loading Conditions on Ship Vibration Characteristics (선박(船舶)의 적화상태(積貨狀態)가 선체진동(船體振動) 특성(特性)에 미치는 영향)

  • K.C.,Kim;M.K.,Kwak;H.M.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.20 no.1
    • /
    • pp.29-33
    • /
    • 1983
  • The loading condition, of a ship, especially a multi-purpose cargo carrier, in service, is often changed. Then, the prediction of natural frequency changes is necessary to provide measures for prevention of ship vibrations. In this paper a simplified method for the above purpose is presented. The bases of the method are analytical solutions for the lateral vibrations of uniform Timoshenko beams carrying a concentrated mass and the Dunkerley's formula. In this method a ship in the standard ballast condition is reduced to a uniform Timoshenko beam having same system parameters as those of the midship section. To investigate the validity of the proposed method, numerical calculations are carried out for a 46,000 DWT bulk carrier and compared with detailed calculations based on the finite difference method. Even in cases those the cargoes in a hold, length of which is about 13% of the ship's length, are reduced to a concentrated mass, the proposed method gives results of several percent differences from the detailed calculations up to the six-noded mode.

  • PDF

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.

A staining method to determine marine microplanktonic organism viability and investigate the efficacy of a ship's ballast water treatment system (선박평형수 처리장치 효율 검증을 위한 해양미소부유생물 생사판별기법)

  • Baek, Seung Ho;Shin, kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4328-4334
    • /
    • 2015
  • We determined a method to determine marine planktonic organism viability using Evan's blue, Aniline blue, and 5-choromethyfluorescein diacetate (CMFDA). The Evan's blue and Aniline blue methods produced bright blue light for dead phytoplankton and zooplankton and were the best dyes to detect dead cells. The staining efficiency of Evan's blue and Aniline blue were ${\geq}90%$ of the original field sample. However, it was difficult to test the efficiency of a ship's ballast water treatment system because detection of living cells. In contrast, the CMFDA method, which is based on measuring cell esterase activity using a fluorimetric stain, was the best dye to detect live cells of almost all phytoplankton species, and staining efficiency was 70%. The CMFDA method is similar to the fluorescein diacetate (FDA) staining method. Therefore, we estimated viability of phytoplankton species using a double-staining method by combining CMFDA and FDA to determine optimum staining efficiency. As a result, the frequency of dying cells based on the double-staining method was 95%, which was significantly higher than that of single CMDFA staining. Our results suggest that a CMDFA + FDA assay is more effective to determine survival of marine plankton and that this method was applicable to investigate the efficacy of a ship's ballast water treatment system.