• Title/Summary/Keyword: Shift constant

Search Result 352, Processing Time 0.036 seconds

ON CLOSING CODES

  • Shaldehi, Somayyeh Jangjooye
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.2
    • /
    • pp.359-366
    • /
    • 2018
  • We extend Jung's result about the relations among bi-closing, open and constant-to-one codes between general shift spaces to closing codes. We also show that any closing factor code ${\varphi}:X{\rightarrow}Y$ has a degree d, and it is proved that d is the minimal number of preimages of points in Y. Some other properties of closing codes are provided. Then, we show that any closing factor code is hyperbolic. This enables us to determine some shift spaces which preserved by closing codes.

Performance Comparisons of some nonparametric detectors (몇가지 비모수 검파기의 성능 비교)

  • 김홍길;송익호;장태주;배진수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.9-15
    • /
    • 1996
  • In this paper, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. The MSS detectors with constant median-shift values are almost equal to the sign detector in Gaussian noise: they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise.

  • PDF

Design and Control of the Phase Shift Full Bridge Converter for the On-board Battery Charger of Electric Forklifts

  • Kim, Tae-Hoon;Lee, Seung-Jun;Choi, Woo-Jin
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 2012
  • This paper describes the design and control of a phase shift full bridge converter with a current doubler, which can be used for the on-board charger for the lead-acid battery of electric forklifts. Unlike the common resistance load, the battery has a large capacitance element and it absorbs the entire converter output ripple current, thereby shortening the battery life and degrading the system efficiency. In this paper a phase shift full bridge converter with a current doubler has been adopted to decrease the output ripple current and the transformer rating of the charger. The charge controller is designed by using the small signal model of the converter, taking into consideration the internal impedance of the battery. The stability and performance of the battery charger is then verified by constant current (CC) and constant voltage (CV) charge experiments using a lead-acid battery bank for an electric forklift.

Data Value Predictor using Stride and Shift (스트라이드와 쉬프트를 사용한 데이터 값 예측기)

  • 최재혁;정진하;윤완오;신광식;최상방
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.235-238
    • /
    • 2003
  • Conventional stride predictor is useful for predicting data values which vary by a constant value. However, when the data values of shift, multiplication, and division instructions are predicted, the stride predictor can't show the best performance. Thus, we propose predictor using stride and shift to improve predictability. The predictor using stride and shift takes advantage of shift values as well as stride values, so that the overall coverage of prediction increases.

  • PDF

Study on the Variation of Dielectronic Constant for an Organic Insulator Film (유기물 절연 박막에 대한 유전상수의 변화에 대한 연구)

  • Oh, Teresa
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.341-345
    • /
    • 2008
  • The SiOC film of carbon centered system was prepared using bistrimethylsilylmethane and oxygen mixed precursor by the chemical vapor deposition. The chemical properties of the SiOC film were analyzed by the contact anlge and FTIR spectra. The dielectric constant of the deposited films decreased after annealing process, and the correlation between the increasing the BTMSM/$O_2$ flow rate ratio and the dielectric constant did not exist. However, the trend of increasing or decreasing of the dielectric constant repeated and there is the correlation ship between the dielectric constant and the Si-O-C bond in the range of $950{\sim}1200\;cm^{-1}$. The dielectric constant decreased between samples with the chemical shift. The lowest dielectric constant was 1.65 at the sample, which was observed the chemical shift.

Characteristic of Hydrogen-oxygen Mixed Gas Power Conversion System (혼합수소발생기용 전력변환장치의 특성)

  • Mun, Sang-Pil;Lee, Hae-Su;Nakaoka, Mutsuo;Jeong, Jang-Geun;Kim, Chang-Il;Jo, Gil-Je;Kim, Sang-Don
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.323-326
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using SCR converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input rower, it has acquired higher input power per Gas quantities at put pulse current. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

Development of Mixed Hydrogen Gas Generator Power Conversion System (Mixed Hydrogen Gas Generator용 전력변환장치 개발)

  • Jung, Jang-Gun;Mun, Sang-Pil;Cho, Gil-Je;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.88-92
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using IGBT converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input power, it has acquired higher input power per Gas quantities at put pulse curren. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

BTMSM 프리커서를 사용한 절연 박막과 유전상수에 대한 연구

  • 오데레사
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.738-739
    • /
    • 2008
  • The SiOC film of carbon centered system was prepared using bistrimethylsilymethane and oxygen mixed precursor by the chemical vapor deposition. The chemical properties of he SiOC film were analyzed by the contact angle and FTIR spectra. The dielectric constant of the deposited films decreased after annealing process, and the correlation between the increasing the BTMSM/O2 flow rate ratio and he dielectric constant did not exist. However, the trend of increasing or decreasing of the dielectric constant repeated and here is the correlation ship between the dielectric constant and the Si-O-C bond in the range of $950{\sim}1200\;cm^{-1}$. The dielectric constant decreased between samples with the chemical shift. The lowest dielectric constant was 1.65 at the sample, which was observed he chemical shift.

  • PDF

Accurate Measurement of THz Dielectric Constant Using Metamaterials on a Quartz Substrate

  • Park, Sae June;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • v.1 no.6
    • /
    • pp.637-641
    • /
    • 2017
  • We present dielectric constant measurements of thin films using THz metamaterials fabricated on a quartz substrate. The resonance shifts of the metamaterials exhibit saturation behavior with increasing film thickness. The saturation frequency shift varies with the real part of the dielectric constant, from which the numerical expression for the particular metamaterial design was extracted. We first performed finite-difference time-domain simulations to find an explicit relationship between the saturated frequency shift and the dielectric constant of a thin film, which was confirmed by the experimental results from conventional techniques. In particular, the quartz substrate enables us to determine their values more accurately, because of its low substrate index. As a result, we extracted the dielectric constants of various films whose values have not been addressed previously without precise control of the film thickness.

A Study on Optimum Value of Design Parameter of Multivariate EWMA and CUSUM charts for Monitoring Dispersion Matrix

  • Chang, Duk-Joon
    • Journal of Integrative Natural Science
    • /
    • v.14 no.3
    • /
    • pp.116-122
    • /
    • 2021
  • Properties and comparison of multivariate CUSUM and EWMA charts for monitoring Σ of multivariate normal N(${\underline{\mu}}$, Σ) process has considered. Comparison of the performances of the considered charts, the numerical values are obtained by simulation with 10,000 iteration in terms of ATS, ANSS and ANSW. We found that EWMA chart with small values of smoothing constant more effectively detects the process changes than with large smoothing constant. And we also found that CUSUM chart with small value of reference value is more effectively detecting the process change than with large reference value. If a process engineer has interest in detecting small amount of shift rather than large shift, he/she can be recommended to use small smoothing constant in EWMA chart and small reference value in CUSUM chart.