• Title/Summary/Keyword: Shielding analysis

Search Result 465, Processing Time 0.031 seconds

Analysis for Shielding Effectiveness of an Enclosure with a Dielectric-B acted Rectangular Aperture (유전체로 막힌 사각 개구를 갖는 함체의 차폐 효과 해석)

  • Kim, Su-Han;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.60-66
    • /
    • 2009
  • A new analytical method is presented for the shielding effectiveness(SE) of an enclosure with a dielectric-backed aperture. The previously proposed methods cannot consider the effect of the dielectric on the aperture. The comparisons among our method, previous method, and commercial programs give good correspondence. The method is used to calculate SE with varying permittivity and thickness of dielectric sheet, probe position, width and height of aperture.

Calculation of induced currents and analysis of shielding effectiveness in finite conductive shield (도전성 유한 차폐판의 유도전류 계산 및 차폐효과 분석)

  • Kang, Dael-Ha;Son, Jung-Dae;Lee, Yung-Sik;Jo, Yeong-Ho;Choi, Phil-Soo;Park, Sang-Ho;Kim, Won-Hi
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.551-552
    • /
    • 2011
  • In this study new evaluation method of eddy currents in conductive shielding sheets are introduced. This method is based on the magnetic flux linkage in rectangular cells. According to this method the allocated amount of memory and the calculation time can be reduced. In this method calculation of magnetic field in any space can be performed by summing contributions of source currents and eddy currents in conductive shielding sheets. This method is applicable to the design of magnetic field-shield.

  • PDF

Magnetic Field Distribution of Power Line Using Amorphous Wire (아몰포스선을 이용한 전력선의 자계분포)

  • Moriyama, T.;Cho, M.W.;Hikita, M.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.609-612
    • /
    • 2001
  • To investigate the magnetic field distribution of power line, we used amorphous wire sensor. And we discuss extremely low frequency magnetic field distribution dependent upon arrangement of power line and shielding pipe made from iron or alumimum materials by both measurement and FEM(Finite Element Method) analysis. Appling current of single phase 60 [Hz] 15 [A] is supplied to copper wire coated enamel resign. As the results, we confirmed that linear characteristics of amorphous wire sensor is very excellent and measurement value agrees with FEM calculation. Magnetic field distribution due to shielding materials is changed by permeability and conductivity.

  • PDF

Analysis of Lighting Overvoltage and Shielding Effect of Overhead Ground Wire on the DC Railway (직류 전차선로의 뇌과전압 해석 및 가공지선 차폐효과 검토)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom;Cho, Han-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.165-167
    • /
    • 2000
  • This paper presents the influence of the lightning overvoltage and the shielding effects of overhead grounding wire on the DC railway system. Modeling of Railway system is established in ATPDraw to perform simulation. The result of simulation reveals that the shielding effects of overhead grounding wire has over 90% than the case which has not it. Therefore it is evaluated that overhead grounding wire should be installed in the DC railway line.

  • PDF

Enhancement of energy efficiency of 3-phase inverter using LFS UMOSFET

  • Cheon, Jin-Hee;Kim, Kwang-Soo
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.677-684
    • /
    • 2020
  • In this paper, the energy efficiency of a 4H-SiC UMOSFET with a local floating superjunction (LFS UMOSFET) was compared with a conventional P-shielding UMOSFET. For analysis, P-shielding UMOSFET and LFS UMOSFET were modeled for energy loss and junction temperature. As a result, LFS UMOSFET showed switching loss reduction of 20.6%. In addition, it was confirmed that LFS UMOSFET is applied to a 3-phase inverter, resulting in 33.2% lower power efficiency and 28.1% lower junction temperature than P-shielding UMOSFET. Electrical characteristics were simulated using Sentaurus TCAD, and the power circuit was simulated with the modelled UMOSFET using PSIM, a power circuit simulator.

Dynamic analysis of coupled wind-train-bridge system considering tower shielding and triangular wind barriers

  • Zhang, Nan;Ge, Guanghui;Xia, He;Li, Xiaozhen
    • Wind and Structures
    • /
    • v.21 no.3
    • /
    • pp.311-329
    • /
    • 2015
  • A method for analyzing the coupled wind-vehicle-bridge system is proposed that also considers the shielding effect of the bridge tower with triangular wind barriers. The static wind load and the buffeting wind load for both the bridge and the vehicle are included. The shielding effects of the bridge tower and the triangular wind barriers are incorporated by taking the surface integral of the wind load. The inter-history iteration is adopted to solve the vehicle-bridge dynamic equations with time-varying external loads. The results show that after installing the triangular wind barriers in the area of the bridge tower, the bridge response and the vehicle safety factors change slightly. The peak value of the train car body acceleration is significantly reduced when the wind barrier size is increased.

Analysis of the Fume Generation Rates in the Flux Cored Arc welding

  • Chae, H.B.;Kim, J.H.;Yang, S.C.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The characteristics of the fume generation in a flux cored arc welding were investigated using the fume collection chamber developed. The Korean Standard concerning the method for the evaluation of the fume generation rate(FGR) was updated by the evaluation method obtained through this study. It was found that the effect of humidity in the test environment should be considered and the automatic welding method had to be employed for the purpose of the exact evaluation of the fume generation rate. The results showed that the fume generation rate was influenced by the welding parameters. The important factors were the welding current arc voltage, travel speed, and contact tip to work distance(CTWD) that affected the heat input as well as the torch angle and the shielding gas flow rate that influenced the shielding effect. The fume generation rate increased as the heat input increased and the shielding effect decreased. It was also observed that the effect of the welding current is much grater than the other welding parameters.

  • PDF

A Study on Performance Improvement of TDMA Noise in a GSM Mobile Phone using the Noise Measure Method (잡음 대책법을 이용한 GSM 방식 이동전화기의 TDMA 잡음 개선에 관한 연구)

  • Oh, Se-Kab;Choi, Jae-Myeong;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.406-411
    • /
    • 2009
  • In this paper, we study the method of noise analysis for analysing TDMA noise in a GSM mobile phone and describe the cause of TDMA noise. And we reduced noise by 9dB, 3.5dB, 6dB, using MIC shielding, equipped bead or capacitance, connected PCB ground based on the difference analysis method, which is one of common noise analysis methods.

  • PDF

An Implementation for Effective Shielding System of Information Electronic Equipments (정보가전기기의 효과적인 차폐시스템 구현)

  • Kim, Jae-Yee;Jeong, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2031-2033
    • /
    • 2004
  • In this paper, electromagnetic wave environment generated from electronic equipments was investigated. Since the main source of electromagnetic waves are electronic equipments, the field intensity of a harmful electromagnetic wave was measured and its harmful level was analyzed. It was also found that the result was 23%${\sim}$38% in case of TV set and microwave oven. Based on this analysis, this study proposed efficient shielding method to suppress unwanted electromagnetic wave.

  • PDF

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF