• Title/Summary/Keyword: Shielding Device

Search Result 115, Processing Time 0.022 seconds

Improving Sensitivity of SAW-based Pressure Sensor with Metal Ground Shielding over Cavity

  • Lee, Kee-Keun;Hwang, Jeang-Su;Wang, Wen;Kim, Geun-Young;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.267-274
    • /
    • 2005
  • This paper presents the fabrication of surface acoustic wave (SAW)-based pressure sensor for long-term stable mechanical compression force measurement. SAW pressure sensor has many attractive features for practical pressure measurement: no battery requirement, wireless pressure detection especially at hazardous environments, and easy other functionality integrations such as temperature, humidity, and RFID. A $41^{\circ}$ YX $LiNbO_3$ piezoelectric substrate was used because of its high SAW propagation velocity and large values of electromechanical coupling factors $K^2$. A silicon substrate with $\~200{\mu}m$ deep cavity was bonded to the diaphragm with epoxy, in which gold was covered all over the inner cavity in order to confine electromagnetic energy inside the sensor, and provide good isolation of the device from its environment. The reflection coefficient $S_{11}$ was measured using network analyzer. High S/N ratio, sharp reflected peaks, and clear separation between the peaks were observed. As a mechanical compression force was applied to the diaphragm from top with extremely sharp object, the diaphragm was bended, resulting in the phase shifts of the reflected peaks. The phase shifts were modulated depending on the amount of applied mechanical compression force. The measured $S_{11}$ results showed a good agreement with simulated results obtained from equivalent admittance circuit modeling.

  • PDF

Review of Magnetocardiography Technology based on SQUIDs (SQUID를 이용한 심자도 기술의 개발동향)

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Kim, K.;Yu, K.K.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

저온 증착 Nano-Crystalline TCO

  • Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.6-6
    • /
    • 2010
  • Indium Tin Oxide (ITO)를 포함한 Transparent Conduction Oxide (TCO)는 LCD, OLED와 같은 Display, 그리고 Solar Cell 등 광신호와 전기신호간 변환이 필요한 모든 Device에 반드시 필요한 핵심 물질로, 특히 고특성 Display의 투명전극에서 요청되는 95% 이상의 투과도와 $15\;{\Omega}/{\square}$ 이하의 면저항 특성을 동시에 만족할 수 있는 기술은 현재까지 Plasma Sputtering 공정으로 $160^{\circ}C$ 이상에서 증착된 ITO 박막이 유일하다. 그러나, 최근 차세대 기술로서 Plastic Film을 기반으로 하는 Flexible Display 및 Flexible Solar Cell 구현에 대한 요구가 급증하면서, Plastic Film 기판위에 Plasma Damage이 없이 상온에 가까운 저온 ($100^{\circ}C$ 이하)에서 특성이 우수한 ITO 투명전극을 형성 할 수 있는 기술의 확보가 중요한 현안이 되고 있다. 지난 10년 동안 $100^{\circ}C$이하 저온에서 고특성의 ITO 또는 TCO 박막을 얻기위한 다양한 연구와 구체적인 공정이 활발히 연구되어 왔으나, ITO의 결정화 온도 (통상 $150{\sim}180^{\circ}C$)이하에서 증착된 ITO박막은 비정질 상태의 물성적 특성을 보여 원하는 전기적, 광학적 특성확보가 어려웠다. 본 논문에선 기본적으로 절연체 특성을 가져야 하는 산화물인 TCO가 반도체 또는 도체의 물리적 특성을 보여주는 기본원리의 고찰을 토대로, 재료학적 특성상 Crystalline 구조를 보여야 하는 ITO (Complex Cubic Bixbyte Structure)가 Plasma Sputtering 공정으로 저온에서 증착될 때 비정질 구조를 갖게 되는 원인을 규명하고, 이를 바탕으로 저온에서 증착된 ITO가 Crystalline 구조를 유지 할 수 있게 하고, Stress Control에 유리한 Nano-Crystalline 박막을 형성하면서 Crystallinity를 임의로 조절 할 수 있는 새로운 기술인 Magnetic Field Shielding Sputtering (MFSS) 공정과 최근 성과를 소개한다. 한편, 또 다른 새로운 저온 TCO 박막형성 기술로서, 유기반도체와 같은 Process Damage에 매우 취약한 유기물 위에 Plasma Damage 없이 TCO 박막을 직접 형성할 수 있는 Neutral Beam Assisted Sputtering (NBAS) 기술의 원리를 설명하고, 본 공정을 적용한 Top Emission OLED 소자의 결과를 소개한다. 또한, 고온공정이 수반되는 Solar Cell용 투명전극의 경우, 통상의 TCO박막이 고온공정을 거치면서 전기적 특성이 열화되는 원인을 규명하고, 이에 대한 근본적 해결 방법으로 ITO 박막의 Dopant인 Tin (Sn) 원자의 활성화를 증가시킨 Inductively Coupled Plasma Assisted DC Magnetron Sputtering (ICPDMS)의 원리와 박막의 물성적 특성과 내열 특성을 소개한다.

  • PDF

Real Time Image Acquisition System using a Image Intensifier and Position Error Verification (영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증)

  • Lee, Dong-Hoon;Kim, Nam-Hoon;Jeong, Jong-Beom
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.331-338
    • /
    • 2017
  • In this study, a portable x-ray generator was manufactured and a real-time image acquisition system was constructed using the image intensifier from the generated generator. We have developed a real - time position error verification system that can verify whether the artificial joint position is different from the initial image from the acquired image. The template image of the region of interest is extracted from the reference image using the pattern matching technique and compared with the image to be compared. As a result, It is shown that real - time position error verification is achieved by displaying the difference angle. This system is portable type, has a self-shielding facility, and the output of the irradiation device can be manufactured in a small size of 1kw and can be used as a portable type. In case of emergency patients in the non-destructive field for industrial use, It has proved effective for use in small areas such as feet.

Theoretical Investigations and measuring Techniques of Geometrical Factor influencing Sensitive Electronic Devices (감도전자장치에 영향을 주는 기하학적 인수의 이론적 연구와 측정)

  • S. K. Lee
    • 전기의세계
    • /
    • v.14 no.1
    • /
    • pp.5-12
    • /
    • 1965
  • In the designs of the sensitive electronic devices such as phase sensitive detector, X-ray diffractometer, and neutron diffractometers, we must take into account the geometrical factors in a coil systems and extraneous stray fields. Input wave forms in such a sensitive electronic devices are often altered by the influence of these factors. Since the magnitude of the stray fields is generally very small, this affection may be removed by applying a good shielding but it is not ease to remove the affection from a geometrical factor. This affection must be however calculated by the theoretical methods and analytical solution in the equation of these factors. The fundamental purpose of this paper lie in the theoretical calculations and practical measurements of the geometrical factor in the coil systems, finite solenoid, and four point prove. In the heoretical calculations, the geometrical factors in the coil systems were calculated by applying the elliptic functions and in the contact points were calculated by applying the elliptic functions and in the contact points were calculated by applying the eigen functions and the infinite series. The measurements were carried out by using the sensitive electronic device made from author's design, as shown in the Fig. 9. The result of this work has verified the essential correctness of theoretical investigations and measuring techniques of geometrical factors on the design of sensitive electronic devices. It also has several advantages such that: (1) all the data obtained may give effective data to designer to work on the field of sensitive electronic devices or microelectronic devices, (2) it has evidently explained the characteristics of electrical investigations and physical definition, and has removed the conventional error of geometrical factors in the coil systems and contact points.

  • PDF

A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of a Commercial Derivative Military Aircraft (상용파생 군용항공기의 전자기 환경 효과(E3) 시험 평가에 관한 연구)

  • Kim, Junghoon;Jung, Inhwan;Lee, Kwangill;Lee, Kyusong;Oh, Seong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.224-232
    • /
    • 2019
  • This paper presents guidelines for the verification test on electromagnetic environmental effects of a commercial derivative military aircraft. To prove the safety-of-flight of a renovated aircraft and appropriate working of electronic system/device, E3 test and analysis at the system level should be performed prior to its operations on real warfare. For the aircraft modified with Falcon 2000S, we concentrate on intra-system EMC, EMRADHAZ (Electromagnetic Radiation Hazards), electrical bonding, P-Static as test and lightning as analysis from a airworthiness certification point of view based on MIL-STD-464, MIL-HDBK-516. As a result, it is verified that the modified aircraft has enough electromagnetic compatibility capabilities under EME(Electromagnetic Environment). In the process, test and analysis methods considering shielding effectiveness(SE) are applied.

Development of VHF-Band Conformal Antenna for UAV Mounting (무인기 탑재용 VHF 대역 형상적응형 안테나 개발)

  • Euntae Jung;Juhyun Lee;Jinwoo Park;Byunggil Yu;Kichul Kim;Jaesoo Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.54-63
    • /
    • 2023
  • In this paper, a VHF band conformal antenna for UAV mounting was developed. The proposed antenna was designed as an shape-adaptive structure by minimizing the antenna height to be advantageous in RCS reduction performance. As for the antenna radiator, the outer radiator was arranged around the inner radiator to apply the CRLH zeroth-order resonance structure. With this structure, the height of the antenna was minimized, and it was reduced by about 70 % compared to the existing blade antenna. In addition, for impedance matching, the intermediate frequency bandwidth of the VHF band was improved through the sleeve pin of the inner radiator, and the low frequency bandwidth of the VHF band was improved by applying an EMI shielding gasket to the shorting pin of the outer radiator. The proposed antenna was manufactured and measured to verify the performance of the device and the performance after UAV mounting. As a result, the standard was satisfied for the operating frequency.

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Analysis on the EMC evaluating method for applying wireless communications in NPP (원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석)

  • Kang, SeungSeok;Lim, Tae Heung;Choo, Jaeyul;Kim, HyungTae;Kim, DaeHee;Byun, Gangil;Park, Jong Eon;Lee, Jun-Yong;Choo, Hosung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2221-2231
    • /
    • 2017
  • In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.