• 제목/요약/키워드: Shielding Device

검색결과 113건 처리시간 0.028초

SQUID를 이용한 심자도 기술의 개발동향 (Review of Magnetocardiography Technology based on SQUIDs)

  • 이용호;권혁찬;김진목;김기웅;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.139-145
    • /
    • 2012
  • Electric activity of cardiac muscles generates magnetic fields. Magnetocardiography (or MCG) technology, measuring these magnetic signals, can provide useful information for the diagnosis of heart diseases. It is already about 40 years ago that the first measurement of MCG signals was done by D. Cohen using SQUID (superconducting quantum interference device) sensor inside a magnetically shielded room. In the early period of MCG history, bulky point-contact RF-SQUID was used as the magnetic sensor. Thanks to the development of Nb-based Josephson junction technology in mid 1980s and new design of tightly-coupled DC-SQUID, low-noise SQUID sensors could be developed in late 1980s. In around 1990, several groups developed multi-channel MCG systems and started clinical study. However, it is quite recent years that the true usefulness of MCG was verified in clinical practice, for example, in the diagnosis of coronary artery disease. For the practical MCG system, technical elements of MCG system should be optimized in terms of performance, fabrication cost and operation cost. In this review, development history, technical issue, and future development direction of MCG technology are described.

저온 증착 Nano-Crystalline TCO

  • 홍문표
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.6-6
    • /
    • 2010
  • Indium Tin Oxide (ITO)를 포함한 Transparent Conduction Oxide (TCO)는 LCD, OLED와 같은 Display, 그리고 Solar Cell 등 광신호와 전기신호간 변환이 필요한 모든 Device에 반드시 필요한 핵심 물질로, 특히 고특성 Display의 투명전극에서 요청되는 95% 이상의 투과도와 $15\;{\Omega}/{\square}$ 이하의 면저항 특성을 동시에 만족할 수 있는 기술은 현재까지 Plasma Sputtering 공정으로 $160^{\circ}C$ 이상에서 증착된 ITO 박막이 유일하다. 그러나, 최근 차세대 기술로서 Plastic Film을 기반으로 하는 Flexible Display 및 Flexible Solar Cell 구현에 대한 요구가 급증하면서, Plastic Film 기판위에 Plasma Damage이 없이 상온에 가까운 저온 ($100^{\circ}C$ 이하)에서 특성이 우수한 ITO 투명전극을 형성 할 수 있는 기술의 확보가 중요한 현안이 되고 있다. 지난 10년 동안 $100^{\circ}C$이하 저온에서 고특성의 ITO 또는 TCO 박막을 얻기위한 다양한 연구와 구체적인 공정이 활발히 연구되어 왔으나, ITO의 결정화 온도 (통상 $150{\sim}180^{\circ}C$)이하에서 증착된 ITO박막은 비정질 상태의 물성적 특성을 보여 원하는 전기적, 광학적 특성확보가 어려웠다. 본 논문에선 기본적으로 절연체 특성을 가져야 하는 산화물인 TCO가 반도체 또는 도체의 물리적 특성을 보여주는 기본원리의 고찰을 토대로, 재료학적 특성상 Crystalline 구조를 보여야 하는 ITO (Complex Cubic Bixbyte Structure)가 Plasma Sputtering 공정으로 저온에서 증착될 때 비정질 구조를 갖게 되는 원인을 규명하고, 이를 바탕으로 저온에서 증착된 ITO가 Crystalline 구조를 유지 할 수 있게 하고, Stress Control에 유리한 Nano-Crystalline 박막을 형성하면서 Crystallinity를 임의로 조절 할 수 있는 새로운 기술인 Magnetic Field Shielding Sputtering (MFSS) 공정과 최근 성과를 소개한다. 한편, 또 다른 새로운 저온 TCO 박막형성 기술로서, 유기반도체와 같은 Process Damage에 매우 취약한 유기물 위에 Plasma Damage 없이 TCO 박막을 직접 형성할 수 있는 Neutral Beam Assisted Sputtering (NBAS) 기술의 원리를 설명하고, 본 공정을 적용한 Top Emission OLED 소자의 결과를 소개한다. 또한, 고온공정이 수반되는 Solar Cell용 투명전극의 경우, 통상의 TCO박막이 고온공정을 거치면서 전기적 특성이 열화되는 원인을 규명하고, 이에 대한 근본적 해결 방법으로 ITO 박막의 Dopant인 Tin (Sn) 원자의 활성화를 증가시킨 Inductively Coupled Plasma Assisted DC Magnetron Sputtering (ICPDMS)의 원리와 박막의 물성적 특성과 내열 특성을 소개한다.

  • PDF

영상증배관을 이용한 실시간 영상획득시스템과 위치오차검증 (Real Time Image Acquisition System using a Image Intensifier and Position Error Verification)

  • 이동훈;김남훈;정종범
    • 재활복지공학회논문지
    • /
    • 제11권4호
    • /
    • pp.331-338
    • /
    • 2017
  • 본 연구에서는 포터블 형 X-ray 발생장치를 제작하였고, 제작된 발생장치로부터 영상증배관을 이용하여 실시간 영상획득시스템 구축하였다. 획득된 영상으로부터 인공관절 위치가 초기 영상과 차이가 있는지를 검증할 수 있는 실시간 위치오차검증 시스템을 개발하였다. 패턴 매칭 기법을 이용하여 간단히 기준영상에서 관심영역 부위의 템플릿영상을 추출하여 비교하고 싶은 비교영상과 비교하여 본 결과 500-1000점 사이의 유사도를 수치로 표시하여 유사정도를 알 수 있었고, x, y 위치와 차이가 나는 각도를 표시해 줌으로써 실시간 위치오차검증이 가능함을 알 수 있었다. 본 시스템은 포터블형이며, 자체 차폐시설을 갖추고 있다. 조사장치의 출력도 1kw의 소형으로 제작되어 이동형으로 사용할 수 있으며, 산업용의 비파괴분야 및 의료기관이 없는 외진 곳에서 발생된 응급환자의 경우 손, 발과 같은 작은 부위의 진단용 분야 등에 활용할 수 있는 유효성을 보여주었다.

감도전자장치에 영향을 주는 기하학적 인수의 이론적 연구와 측정 (Theoretical Investigations and measuring Techniques of Geometrical Factor influencing Sensitive Electronic Devices)

  • 이시규
    • 전기의세계
    • /
    • 제14권1호
    • /
    • pp.5-12
    • /
    • 1965
  • In the designs of the sensitive electronic devices such as phase sensitive detector, X-ray diffractometer, and neutron diffractometers, we must take into account the geometrical factors in a coil systems and extraneous stray fields. Input wave forms in such a sensitive electronic devices are often altered by the influence of these factors. Since the magnitude of the stray fields is generally very small, this affection may be removed by applying a good shielding but it is not ease to remove the affection from a geometrical factor. This affection must be however calculated by the theoretical methods and analytical solution in the equation of these factors. The fundamental purpose of this paper lie in the theoretical calculations and practical measurements of the geometrical factor in the coil systems, finite solenoid, and four point prove. In the heoretical calculations, the geometrical factors in the coil systems were calculated by applying the elliptic functions and in the contact points were calculated by applying the elliptic functions and in the contact points were calculated by applying the eigen functions and the infinite series. The measurements were carried out by using the sensitive electronic device made from author's design, as shown in the Fig. 9. The result of this work has verified the essential correctness of theoretical investigations and measuring techniques of geometrical factors on the design of sensitive electronic devices. It also has several advantages such that: (1) all the data obtained may give effective data to designer to work on the field of sensitive electronic devices or microelectronic devices, (2) it has evidently explained the characteristics of electrical investigations and physical definition, and has removed the conventional error of geometrical factors in the coil systems and contact points.

  • PDF

상용파생 군용항공기의 전자기 환경 효과(E3) 시험 평가에 관한 연구 (A Study on Electromagnetic Environmental Effects(E3) Test and Evaluation of a Commercial Derivative Military Aircraft)

  • 김정훈;정인환;이광일;이규송;오성
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.224-232
    • /
    • 2019
  • This paper presents guidelines for the verification test on electromagnetic environmental effects of a commercial derivative military aircraft. To prove the safety-of-flight of a renovated aircraft and appropriate working of electronic system/device, E3 test and analysis at the system level should be performed prior to its operations on real warfare. For the aircraft modified with Falcon 2000S, we concentrate on intra-system EMC, EMRADHAZ (Electromagnetic Radiation Hazards), electrical bonding, P-Static as test and lightning as analysis from a airworthiness certification point of view based on MIL-STD-464, MIL-HDBK-516. As a result, it is verified that the modified aircraft has enough electromagnetic compatibility capabilities under EME(Electromagnetic Environment). In the process, test and analysis methods considering shielding effectiveness(SE) are applied.

무인기 탑재용 VHF 대역 형상적응형 안테나 개발 (Development of VHF-Band Conformal Antenna for UAV Mounting)

  • 정은태;이주현;박진우;유병길;김기철;정재수
    • 한국군사과학기술학회지
    • /
    • 제26권1호
    • /
    • pp.54-63
    • /
    • 2023
  • In this paper, a VHF band conformal antenna for UAV mounting was developed. The proposed antenna was designed as an shape-adaptive structure by minimizing the antenna height to be advantageous in RCS reduction performance. As for the antenna radiator, the outer radiator was arranged around the inner radiator to apply the CRLH zeroth-order resonance structure. With this structure, the height of the antenna was minimized, and it was reduced by about 70 % compared to the existing blade antenna. In addition, for impedance matching, the intermediate frequency bandwidth of the VHF band was improved through the sleeve pin of the inner radiator, and the low frequency bandwidth of the VHF band was improved by applying an EMI shielding gasket to the shorting pin of the outer radiator. The proposed antenna was manufactured and measured to verify the performance of the device and the performance after UAV mounting. As a result, the standard was satisfied for the operating frequency.

투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구 (Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners)

  • 양해두;홍선숙;성민숙;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석 (Analysis on the EMC evaluating method for applying wireless communications in NPP)

  • 강승석;임태흥;주재율;김형태;김대희;변강일;박종언;이준용;추호성
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2221-2231
    • /
    • 2017
  • 본 논문에서는 원전용 계측 제어기기를 진단하고 유지 보수하기 위한 무선통신기술의 국내외 적용 사례, 프로토콜(Wi-Fi, Zigbee, Z-wave, WirelessHart 등) 및 그에 따른 전파특성을 조사하였다. 또한, 원전 내 무선통신기술 적용시 우려되는 전자파 간섭(EMI/RFI)과 관련하여 국내 규제지침 KINS/RG-N03.09(개정 2판)에서 승인한 RG. 1.180(Regulatory Guide 1.180 rev.1), MIL-STD 461E, 및 IEC 61000-4의 차이를 분석하였다. 추가적으로 기존의 EMC 관련 규제에 포함되어 있지 않았던, 실내 환경에서의 구조적 특징, 전파산란 및 차폐효과, 실내 감쇄모델을 고려한 전자파 영향성 평가요소에 대해서도 연구하였다.

핵의학 종사자에서 손 부위의 외부 피폭선량 연구 (Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers)

  • 박준철;표성재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2012
  • 최근 최첨단 핵의학 영상기술의 발달로 임상적 이용이 증가되어 방사선 선원을 취급하는 핵의학과 작업종사자의 몸통 부위와 손 부위에 노출되는 외부 피폭선량을 평가하고 검사 빈도가 높은 전신 뼈검사(Whole body Bone Scan)와 양전자 단층촬영(PET/CT)시 방사선 선원($^{99m}Tc$-HDP, $^{18}F$-FDG)의 취급 및 검사에 따른 손 부위 피폭선량을 측정하고자 한다. 방사선 선원 취급 시 방호구 착용 및 손 부위를 측정 할 수 있는 선량계 보유 여부를 알아보기 위해 4개의 의료기관에 설문 하였다. 방사선 선원을 직접 분주하고 주사하는 숙련된 작업종사자의 가슴과 약지손가락에 열형광 선량계을 착용하여 누적된 외부 방사선 선량을 측정하고 손 부위의 외부 방사선량 측정을 위해 구간별 일일 방사선 선원으로부터 노출되는 선량과 시간을 포켓도시메터를 이용하여 각각 측정 하였다. 인천광역시 4개 의료기관을 대상으로 조사한 결과 손 부위의 방사선 피폭선량 측정기를 구비한 의료기관은 1곳을 제외한 3곳은 구비하지 않았고 차폐기구 사용은 방사선 선원으로부터 몸통을 보호하기 위해 차폐기구를 사용한 곳이 대부분 이었고, 일부 의료기관에서는 사용하지 않는 곳도 있었다. 방사선 선원을 직접 분배하고 투여하는 핵의학과 작업종사자의 손 부위 외부피폭 선량은 몸통부위보다 약 2배 이상 많은 선량을 받았고, 검사 빈도가 높은 전신 뼈 검사와 양전자 단층촬영 시 각 구간별 외부피폭 선량을 보면 방사성의약품 합성 및 분배용기 장착, 분배, 투여, 이동 순으로 각각 나타났다. 또한 방사선 선원 투여시 방호구 착용 전/후 손 부위의 피폭선량을 측정한 결과 통계적 유의한 차이가 있었다. 연구결과 작업종사자의 유효선량에는 못 미치지만 비 작업종사자보다 비교적 높은 선량을 받고 있어 방사선 선원을 근거리에서 노출되는 작업종사자는 안전관리 규정을 준수하고 손 부위 선량계(Ring TLD)를 착용하여 방사선 선원으로부터 피폭 저감을 위한 활동을 하여야 한다.

FOWLP 적용을 위한 Cu 재배선과 WPR 절연층 계면의 정량적 계면접착에너지 측정방법 비교 평가 (Comparison of Quantitative Interfacial Adhesion Energy Measurement Method between Copper RDL and WPR Dielectric Interface for FOWLP Applications)

  • 김가희;이진아;박세훈;강수민;김택수;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제25권2호
    • /
    • pp.41-48
    • /
    • 2018
  • Fan-out wafer level packaging (FOWLP) 적용을 위한 최적의 Cu 재배선 계면접착에너지 측정방법을 도출하기 위해, 전기도금 Cu 박막과 WPR 절연층 계면의 정량적 계면접착에너지를 $90^{\circ}$ 필 테스트, 4점 굽힘 시험법, double cantilever beam (DCB) 측정법을 통해 비교 평가 하였다. 측정 결과, 세 가지 측정법 모두 배선 및 패키징 공정 후 박리가 일어나지 않는 산업체 통용 기준인 $5J/m^2$보다 높게 측정되었다. 또한, DCB, 4점 굽힘 시험법, $90^{\circ}$ 필 테스트 순으로 계면접착에너지가 증가하는 거동을 보였는데, 이는 계면파괴역학 이론에 의해 위상각 증가에 따라 이종재료 계면균열 선단의 전단응력성분 증가에 따른 소성변형에너지 및 계면 거칠기 증가 효과에 의한 것으로 설명이 가능하다. FOWLP 재배선에 대한 최적의 계면접착에너지 도출을 위해서는 시편제작 공정, 위상각 차이, 정량적 측정 정확도 및 결합력 크기 등을 고려하여 4점 굽힘 시험법 또는 DCB 측정법을 적절히 혼용 사용하는 것이 타당한 것으로 판단된다.