• Title/Summary/Keyword: Shielding Analysis

Search Result 462, Processing Time 0.024 seconds

Analysis on the EMC evaluating method for applying wireless communications in NPP (원전 내 무선통신 적용에 대한 전자파 적합성 평가방법 분석)

  • Kang, SeungSeok;Lim, Tae Heung;Choo, Jaeyul;Kim, HyungTae;Kim, DaeHee;Byun, Gangil;Park, Jong Eon;Lee, Jun-Yong;Choo, Hosung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2221-2231
    • /
    • 2017
  • In this paper, we surveyed previous cases, network protocols (such as Wi-Fi, Zigbee, Z-wave, and WirelessHart) and propagation characteristics on the application of maintaining equipments for instrumentation and control (I&C) using wireless communication techniques inside the nuclear power plant (NPP). In addition, we compared and analyzed the difference of detailed regulations with respect to the electromagnetic interference (EMI) and radio frequency interference (RFI) in the Regulatory Guide 1.180 rev. 1 (RG. 1.180) for adopting the wireless communication techniques inside the NPP, and other regulations, such as MIL-STD 461E and IEC 61000-4, that are recognized in the KINS/RG-N03.09 (Rev. 2). Furthermore, we investigated evaluating factors about electromagnetic properties by considering indoor environments, wave scattering, shielding effectiveness, and the indoor wave attenuation model that were not included in the current electromagnetic compatibility regulation.

Study on Analysis Technique Comparison and Evaluation of High Thermal Conductivity Concrete with Magnetite Aggregates and Steel Powder (자철광 및 철분말을 혼입한 고열전도 콘크리트의 열전도 평가 및 해석기법 비교에 대한 연구)

  • Lee, Hack-Soo;Kim, Min-Kyu;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.315-321
    • /
    • 2014
  • Concrete as a construction material is widely used in nuclear vessel and plant for excellent radiation shielding. However the isolation characteristics in concrete may affect adversely in the case of fire and melt-down in nuclear vessel since temperature cooling down is very difficult from outside. This study is for development of high thermal conductive concrete, and its mechanical and thermal properties are evaluated. Magnetite aggregates with volume ratio of 42.3% (maximum) and steel powder of 1.5% are replaced with normal aggregates and thermal properties are evaluated. Thermal conductivity little increases by 30% addition of magnetite but rapidly increases afterwards. Finally thermal conductivity is magnified to 2.5 times in the case of 42.3% addition of magnetite. Steel powder has a positive effect on high thermal conduction to 106~113%. Several models for thermal conduction like ACI, DEMM, and MEM are compared with test results and they are verified to reasonably predict the thermal conductivity with increasing addition of magnetite aggregates and steel powder.

A Study on the Illumination Environment of Ultrasound Examination Room (초음파 검사실의 조도 환경에 관한 연구)

  • Im, In-Chul;Lee, Hyo-Yeong;An, Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • The purpose of study is provide the basic data for set up proper illuminance of examination room that put purpose of an empirical study basic data about examination environment setting of the ultrasonic examination on design the examination environment of a new ultrasonic examination. As a method, to investigate the ultrasonic environment related to illumination to take a survey on the ultrasonic examination about test object to 48 parts of six units of general hospital in Busan. As a result, All Door + Curtain showed high scores in analyzing the gender, age, examination part in the case of ultrasonic examination room shielding and LED and light source control is required in the case of kind of light source. In the ultrasonic examination environment survey, the illuminance brightness is average 10 Lux which is included illuminance brightness range recommended the WHO and CEC and illuminance brightness of ultrasonic examination waiting room(ultrasonic examination waiting room, corridor) indicate average 300~800 Lux and it satisfied hospital illumination environment more than 300 Lux recommended by KSA 3011. In conclusion, Basic data suggested that improved future ultrasonic examination environment or designed new examination room on the basis of analysis result of general background and ultrasonic examination related to environment factor.

A Study on Photon Characteristics Generated from Target of Electron Linear Accelerator for Container Security Inspection using MCNP6 Code (MCNP6 코드를 이용한 컨테이너 보안 검색용 전자 선형가속기 표적에서 발생한 광자 평가에 관한 연구)

  • Lee, Chang-Ho;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-hee;Lee, Ji-Eun;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.193-201
    • /
    • 2020
  • The purpose of this study is to evaluate the photon characteristics according to the material and thickness of the electrons incidented through a linear accelerator. The computer simulation design is a linear accelerator target consisting of a 2 mm thick tungsten single material and a 1.8 mm and 2.3 mm thick tungsten and copper composite material. In the research method, First, the behavior of primary particles in the target was evaluated by electron fluence and electron energy deposition. Second, photons occurring within the target were evaluated by photon fluence. Finally, the photon angle-energy distribution at a distance of 1 m from the target was evaluated by photon fluence. As a result, first, electrons, which are primary particles, were not released out of the target for electron fluence and energy deposition in the target of a single material and a composite material. Then, electrons were linearly attenuated negatively according to the target thickness. Second, it was found that the composite material target had a higher photon generation than the single material target. This confirmed that the material composition and thickness influences photon production. Finally, photon fluence according to the angular distribution required for shielding analysis was calculated. These results confirmed that the photon generation rate differed depending on the material and thickness of the linear accelerator target. Therefore, this study is necessary for designing and operating a linear accelerator use facility for container security screening that is being introduced in the country. In addition, it is thought that it can be used as basic data for radiation protection.

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle (장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析))

  • Lee, Tae-Young;Ha, Chung-Woo;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.90-96
    • /
    • 1984
  • Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

  • PDF

Shielding Analysis for Industrial Package: Focusing on Dry Active Waste (IP형 운반용기 차폐해석-잡고체폐기물을 중심으로)

  • Lee Kang-Wook;Cho Chun-Hyung;Jang Hyun-Kie;Choi Byung-Il;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.523-530
    • /
    • 2005
  • In this study, maximum exposure rate at DAW(Dry Active Waste) drum surface which is satisfying regulation limit was calculated for conceptual design of IP(Industrial Package). DAW can be classified as combustible and non-combustible waste and the calculation was conducted for single and mixed radionuclide for each type of waste. In case of combustible waste that mixed radionuclide is uniformly distributed, the maximum exposure rates at drum surface were 3.60E-01, 8.85E-01 and 1.27E+01 mSv/hr for IP Type 1, 2-a and 2-b, respectively. and 3.60E-01, 8.85E-01, 1.27E+01 mSv/hr for single radionuclide(Co-60). In case of non-combustible waste that mixed radionuclide is uniformly distributed, the maximum exposure rates at drum surface were 7.14E-01, 1.83E+00, 2.69E+01 mSv/hr for IP Type 1, 2-a and 2-b, respectively. and 7.13E-01, 1.81E-01, 2.62E+01 mSv/hr for single radionuclide(Co-60). Through this study, the maximum amount of DAW can be transported by IP was suggested as maximum exposure rate at drum surface and the calculation for the other types of waste will be conducted.

  • PDF

A Study of the Registration of Simulator Images and Portal Images Using Landmarks in Radiation Treatment (랜드마크 (Landmark)를 이용한 방사선 치료 X선 시뮬레이터 영상과 포탈영상의 비교법 연구)

  • 이정애;서태석;최보영;이형구
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.177-184
    • /
    • 2001
  • The goal of radiation treatment is to deliver a prescribed radiation dose to the target volume accurately while minimizing dose to normal tissues. Due to inaccurate placement of field and shielding block and patient's movement, there could be displacement errors between the planed and treatment regions. In order to verify the location of radiation treatment, we in this study developed the registration algorithm of the x-ray simulator images and portal images and quantified the inaccuracy in terms of shift, scale and rotation. The algorithm for registration of pairs of radiation fields consists of the alignment of pairs of radiation images by points matching and field displacement analysis by field boundary matching. In the first step, paired surface landmarks are matched to calculate the transformation parameters (scale, rotation and shift) using the corresponding line pairs which are created by connecting two landmarks of each image. In the next step, portal field boundary is extracted and then the two field boundaries are matched by the $\rho$-$\theta$ technique. Applying the phantom portal images, detection errors were calculated to be less than 2mm in translation, 1$^{\circ}$ in rotation and 1% in scale. In conclusion, we quantitatively analyzed the displacement error of x-ray simulator images and portal images. The present results could contribute to the study of the radiation treatment verification.

  • PDF

Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model (축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom;Kwon, Sin-Won;Gil, Kyung-Suk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

Monitoring Urban Ecological corridors in Gwanggyo New Town Using Camera Trapping (카메라트래핑을 활용한 광교신도시 내 도시형 생태통로 모니터링)

  • Park, Il-Su;Kim, Whee-Moon;Kim, Seoung-Yeal;Park, Chan;Song, Won-Kyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.1
    • /
    • pp.69-80
    • /
    • 2021
  • The new town in Korea, developed as a large-scale housing plan, has created urban ecological corridors to provide habitat and movement routes to wildlife and to promote natural ecological flow. This study aimed to investigate the use of wildlife in 10 ecological corridors in Gwanggyo New Town through camera trap technology and confirm effectiveness by identifying environmental factors affecting the use of wildlife's urban ecological corridors. Our researchers installed 20 unmanned sensor cameras at each the entrance and exit of the ecological corridors, and monitored urban wildlife for 10 weeks. According to the monioring results, the main species in Gwanggyo New Town were identified not only raccons, cats, water deer, korean hare and avain but also magpies, dove, eurasian tree sparrow, ring-necked pheasant, and eurasian jay. The number of uses ecological corridors of urban residents was 801(13.49%), as high as that of urban wildlife (1,140, 19.20%), which was judged to have disturbed the use of ecological corridors by wildlife. However, most dominant species of urban wildlife are nocturnal so that, it was judged that they share home range with urban residents at a time interval. In addition, according to the correlation analysis results between the mammal using rate of the urban ecological corridors and environmental factors(ecological corridor-specific length, ecological corridor-specific width, cover degree, shielding degree, connected green area, separation of movement routes, and presence of streetlights), environmental factors were not statistically significant. However, the more the area of green space connected to ecological corridors, the more increasing the mammal using rate of ecological corridor(r=0.71, p<0.05). Therefore, the area of green space connected to the ecological corridors that is associated with rate of wildlife using corridors should be considered as a priority when developing an urban ecological corridors. In the future, this study will extend the observation period of the ecological corridors and continuously accumulate data by adding the number of observation cameras. Furthermore, it is expected that the results of this study can be used as basic data for the standards for urban ecological corridors installation.