• Title/Summary/Keyword: Shield Method

Search Result 427, Processing Time 0.031 seconds

Development of Scheduler Based on Simulation for Phone Camera Lens Module Manufacturing System (폰카메라 렌즈모듈 제조시스템을 위한 시뮬레이션 기반의 스케줄러 개발)

  • Kim, Jae Hoon;Lee, Seung Woo;Lee, Dae Ryoung;Park, Chul Soon;Song, Jun Yeob;Moon, Dug Hee
    • Journal of the Korea Society for Simulation
    • /
    • v.23 no.4
    • /
    • pp.131-142
    • /
    • 2014
  • Phone camera lens module is assembled with a barrel, multiple lenses, multiple spacers and a shield. The major processes of manufacturing system are injection molding, coating and assembly processes, and each process has multiple machines. In this paper, we introduce a scheduler based on simulation model which can be used for frequent rescheduling problem caused by urgent orders, breaking down of molds and failures of machines. The scheduling algorithm uses heuristic Backward-Forward method, and the objective is to minimize the number of tardy orders.

The study on the DC Ic measurement and AC loss in the 22.9kV, 50MVA HTS power cable (22.9kV/50MVA급 고온초전도 전력케이블의 DC Ic 측정 및 교류손실에 관한 연구)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.808-809
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established. The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. For the analysis of AC losses in an HTS power cable, 2-dimensional numerical calculation was carried out to define the magnetic field distribution. We calculated the magnetization losses in the HTS core of that cable from these fields. These calculated results are in accordance with those of experiment.

  • PDF

All-Inside Technique of Anterior Cruciate Ligament Reconstruction using Central Quadriceps Tendon and Patella Bone Block (관절강 내에서 모든 수술 과정을 시행하는 관절경적 전방십자인대 재건술)

  • Jeong, Hwa-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.66-71
    • /
    • 1997
  • The all inside anterior cruciate ligament reconstruction technique places an anterior ligament substitutes within two bony sockets rather than hone tunnel. This approach is accomplished through arthroscopic three portal which avoids the surgical exposure and morbidity associated with creating traditional bone tunnel. This technique has several distinct advantages when compared with the traditional ACL reconstruction through the bone tunnels. It offers the surgeon a less morbid method for ACL reconstruction that positions an ACL substitute at the anatomic attachment sites of the original ACL with two bone sockets, obviating the need for traditional bone tunnels. Graft fixation at or near the anatomic attachment points of the original ACL minimizes creep with early range of motion and reduces the abrasive 'wind-shield wipe' motion of the graft which occur with bone plugs positioned inside bone tunnels. The sagittal posterior angle to the tibial socket increases fixation strength to pullout with anterior translation force for the tibia on the femur. This technique is not graft specific and can accomodate any graft in which graft length can be customized to the intraarticular native ACL length.

  • PDF

A Study on the Evaluation of Motorcycle Jacket with Built-in Airbag (에어백 장착 모터사이클 쟈켓의 성능 실험방법 연구)

  • Do Wol-Hee;Choi Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.837-846
    • /
    • 2005
  • The purpose of this study is to suggest a standard of guidance for testing the performance and safety of motorcycle jacket with built-in airbag. The method of testing were as follows: The effects of the motorcycle jacket with built-in airbag are experimentaly investigated according to neck injury of FMVSS 208. The experiment consists of the crash simulation test by shield and the impact test. The head and neck injuries are evaluated based on industrial standards. Also, the displacements of the head and neck and chest are observed by film analysis. Using the results of the crash simulation test, neck injury$(N_ij)$ is discussed and the peak chest deflection of the results of the impact test, chest injury is pursued. Neck injury$(N_ij)$ of the result of the crash test show that the chance of a serious wound is $18\%$ if rider wear the R&D motorcycle jacket with built-in airbag(Type A). Chest injury is expected by peak chest deflection of the result of the impact test. The result of the peak chest deflection show that the reduction effect in chest injury of Type A motorcycle jacket is $10.3\%$.

Study on Effective Shielding of Secondary Radiation Generated by High Energy Proton Accelerator (고 에너지 양성자 가속기에서 생성되는 2차 방사선의 효과적인 차폐에 관한 연구)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.383-388
    • /
    • 2020
  • High-energy proton accelerators continue to be increasingly used in medical, research and industrial settings. However, due to the high energy of protons, a large number of secondary radiation occurs. Among them, neutrons are accompanied by difficulties of shielding due to various energy distribution and permeability. So In this study, we propose a shielding method that can shield neutrons most efficiently by using multiple-shielding material used as a decelerating agent or absorbent as well as a single concrete shielding. The flux of secondary neutrons showed a greater decrease in the flux rate when heavy concrete was used than in the case of ordinary concrete, and the maximum flux reduction was observed at the front position when using multiple shields. Multiple shielding can increase shielding efficiency more than single shielding however, As the thickness of the multiple shielding materials increased, the decline in flux was saturated. The mixture material showed higher shielding results than the polyethylene when using boron carbonate.

지하수의 라듐/라돈 동시측정을 위한 백그라운드 감마선 제어

  • Lee Gil-Yong;Yun Yun-Yeol;Jo Su-Yeong;Kim Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.308-311
    • /
    • 2005
  • [ $^{222}Rn\;and\;^{226}Ra$ ] in groundwater were determined simultaneously using a gamma-spectroscopy. A nitrogen flushing equipment has been used for elimination and stabilization of high and unstable background activity due to the radon and its progenies in counting shield and room. The aim of present work was to control the background activity for simultaneous measurement of radium$(^{226}Ra)$ and radon$(^{222}Rn)$ in groundwater using a gamma-spectrometry. Background activity was about 1.0dps and the standard deviation was about 50%, The background activity could be minimized using nitrogen flushing equipment in the range of 0.1 to 0.5 and the RSD was about 5% at the experimental condition. The detection limit of $^{222}Rn\;and\;^{226}Ra$ in groundwater was 0.5dps/L in the background control method. In most groundwater used in the work, radon activity was more than the detection limit. However, radium activity in some groundwater was less than the detection limit. If the low level radium in groundwater must be measured, preconcentration process such as concentration should be performed before measuring the groundwater.

  • PDF

Performance Estimation and Test of Protype Pulse Tube Cryopump (맥동관형 크라이오펌프 시제품 성능예측과 평가)

  • In, Sang Ryul;Kang, Sang Paek
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2013
  • The cryopump of the pulse tube type has been developed successfully, and manufacturing of a prototype pump is finished under leading of Woosung Vacuum. The target pumping speed of the prototype pump is above 3,600 L/s for nitrogen with the intake port of 14 inches I.D (16 inches O.D). For designing optimally the pump structure including the charcoal array, thermal shield, and baffle, the pumping speed was simulated for various configurations through Monte Carlo method. Pumping performances of the protype cryopump manufactured on the basis of optimal design were conformed experimentally with a standard test system and procedures. The measured $N_2$ pumping speed of the prototype cryopump was 4,600 L/s which agreed well with simulated one and exceeded the target value.

Pigmentation of Diketopyrrolopyrroles Compound through Solvent Thermal-treatment and Its Property (용매 열처리법을 통한 diketopyrrolopyrroles 화합물의 안료화 및 그 특성)

  • Kim, Jae Hwan;Yang, Seok Won;Kim, Dae-Sung;Wu, Guan Zhu;Lee, Gun-Dae;Park, Seong Soo
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.357-362
    • /
    • 2014
  • To prepare diketopyrrolopyrrole (DPP) red 254 pigment with high shield and bright color, DPP red 254 crude previously synthesized was treated at various thermal-treat temperature, addition derivative and ball-milling. The properties of samples were measured by the means of FT-IR, UV-Vis spectroscopy, TEM, PSA, BET surface area analyzer, viscometer and spectrophotometer. It was found that solvent thermal-treatment of the sample prepared after ball-milling as nano-scale was very effective method in pigmentation process.

Induced Voltages on LAN Cables Due to Incident Electromagnetic Fields (외부 전자파에 의한 LAN 케이블의 유도전압)

  • 주재철;박범준;김종국;이현영;임계재;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.719-726
    • /
    • 1999
  • Multiconductor transmission line(MTL) equations are solved by FDTD method to examine the coupling between incident electromagnetic fields and multiconductor transmission lines. The measurement of induced voltages on UTP Category 5 and STP Category 5 cables which are used as LAN cables is carried out using a TEM cell where uniform and strong TEM fields can be established. The comparison between measured and simulated results shows good agreement. It is also found that grounding of shield foil at both terminations and small grounding resistance give good shielding effects for STP Category 5.

  • PDF

A Study on the Single Line-to-Ground Fault Analysis of HTS Power Cable (초전도 전력케이블의 1선 지락고장 특성 해석에 관한 연구)

  • Je, Hyang-Ho;Bang, Jong-Hyun;Kim, Jae-Ho;Sim, Ki-Deok;Jo, Jeon-Wook;Jang, Hyun-Man;Lee, Su-Kil;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1259-1260
    • /
    • 2006
  • High temperature superconducting(HTS) power cable is expected to be used for power transmission lines supplying electric power for densely populated cities in the near future. Commercializing of HTS power cable is coming. Simulation is required for safety before install of HTS power cable, a fabrication model used at the power system simulation. In this paper, we shows a single line-to ground fault analysis in the grid system which has a 100m length HTS power cable. The authors developed a single line-to-ground fault current calculation method which is considering the shield layer of HTS power cable. In the calculation, the T type equivalent circuit is used to derive the mutual inductance of the HTS power cable.

  • PDF