• 제목/요약/키워드: Shear Test

검색결과 4,458건 처리시간 0.029초

하프 PC판과 후타설콘크리트 접합면의 면내전단강도에 관한 실험적 연구 (An Experimental Study on In-Plane Shear Strength of the Interface between Half PC Plate and Cast-in-Place Concrete Plate)

  • 신동원;고만영;이동우;김용부
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.513-518
    • /
    • 1998
  • In Half Precast Concrete Method, such as composite slab and composite wall, Interface between half PC plate and cast-in-place concrete is occurred. And this interface endure lastly in-plane shear which is occurred by external force. Therefore, test was executed to study in-plane shear strength of interface between half PC plate and cast-in-place concrete. In this test, Experimental parameters are finishing condition of the interface, cohesion of concrete, existence and nonexistence of re-bar truss, and angle and direction of lattice of re-bar truss. Comparing and analyzing experimental results, conclusions are obtained as follows. (1) In-plane shear strength of wide interface in composite plate is more affected by the roughness of interface than re-bar truss. And cohesion of concrete contribute to increasing in-plane shear strength. Therefore it seems that the interface should be roughen and kept clean to improve in-plane shear strength. (2) It seems that shear friction equation in ACI code can be sagely available for design of in-plane shear of composite plate.

  • PDF

트러스형 금속 샌드위치 판재에서 심재의 전단특성계수의 실험적 결정 (Experimental Investigation of Shear Modulus of a Core in a Metallic Sandwich Plate with a Truss Core)

  • 정창균;성대용;양동열;문경제;안동규
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.67-73
    • /
    • 2007
  • A sandwich plate with a truss core is composed of two face sheets and a pyramidal truss core between face sheets. This paper shows how to estimate the shear modulus of a truss core, experimentally. To determine the shear modulus of truss cores, 3-point bending tests are performed. For tests, metallic sandwich beams with truss cores are fabricated. Two kinds of truss cores are tested to investigate the shear modulus. Each test is repeated under different widths in order to increase accuracy. As a result, the shear modulus of sandwich beam is properly calculated. The deflection of a sandwich beam with a truss core by shear deformation takes the major contribution of the total deflection and the shear modulus of sandwich beam should be considered whenever it is designed.

반복하중을 받는 철근콘크리트 전단벽체의 접합방식에 따른 구조성능 평가 (Structural Performance Evaluation of Reinforced Concrete Shear Walls with Various Connection Type Under Load Reversals.)

  • 신종학;하기주;권중배;전찬목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 1997
  • In this study, nine reinforced concrete infilled frames involved bare frames were tested during vertical and cyclic loads simultaneously. This test programs were carried to investigate the horizontal strength and the crack propagation in variance with hoop reinforcement ratio. All specimens were modeling in one-third scale size. In this experimental program structural performance of reinforced concrete shear wall were focus at connection types. Based on the test results, the following conclusions are made. In the boundary column member of reinforced concrete shear wall, increasing the ratio of hoop bar in two or three times, in the fully babel type, the shear and horizontal strength of specimens were increased 1.1-1.2 times than that of fully rigid frame. And infilled shear wall specimen were increased 1.17-1.27 times than that. Fully rigid babel type shear wall specimens were increased 5.7~8.0 times, and infilled shear wall specimens were increased about 4.0~5.6 times than that of infilled shear wall specimens.

  • PDF

Stuttgart 콘크리트 보 전단실험의 재해석을 통한 합리적 전단모델 연구 (A Study on the Rational Shear Model by interpretation of Stuttgart Beam Shear Test)

  • 김우;모귀석;정제평
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.884-889
    • /
    • 2003
  • Based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subject to combined shear and moment loads, the shortcomings of present truss models are discussed. The core of the theory is that a new perspective on the shear strength can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be designed using the simple truss having curved compression chord, while the beam action between the two chords can be modeled using a parallel chord truss with MCFT or RA-STM. The compatibility of deformation associated to the two action is taken into account by employing a characteristic factor a. The new model was examined by the Stuttgart beam shear tests, and the results show that the present approach provides good estimates of stirrup contribution and concrete contributions.

  • PDF

자연 퇴적 점성토의 비배수 전단강도에 미치는 전단 속도의 영향 (Shear Rate Effect on Undrained Shear Behavior of Holocene Clay)

  • 정민수;채종길;시부야 사토루
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1181-1192
    • /
    • 2008
  • A laboratory investigation was carried out into effects of strain rate on undrained shear behavior of Holocene clay underneath Kobe Airport with an objective to evaluate the factor of safety of the retaining structure built on it. It was examined in a series of triaxial compression and extension tests performed using different rate of axial straining. A comparative compression test in which the strain rate was changed in steps was also carried out. Similar tests were performed in constant-volume direct shear box (DSB) test. And, the deformation characteristics of the clay were also examined in order to evaluate the variation of stiffness during undrained shearing. It was found that the undrained strength increased with not only the shear rate but also the consolidation period. ISOTACH properties seemed a key to govern the undrained shear behavior.

  • PDF

콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구 (An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment)

  • 김민성;이승엽;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

프리캐스트 바닥판 PSC 합성거더 교량의 거동 (Behavior of PSC Composite Bridge with Precast Decks)

  • 정철헌;현병학
    • 대한토목학회논문집
    • /
    • 제26권5A호
    • /
    • pp.873-880
    • /
    • 2006
  • 본 논문에서는 기존의 수평전단 설계식을 적용하여 프리캐스트 바닥판 PSC 합성거더 교량을 설계, 제작하였다. 피로하중에 대한 바닥판과 거더 그리고 전단연결부의 내구성과 거동특성을 평가하기 위하여 피로실험을 수행하였다. 실험결과 200만회 반복하중을 재하한 후 바닥판과 거더의 균열 및 잔류처짐은 발생하지 않았으며, 휨강성의 감소없이 선형거동을 나타냈다. 그리고 전단연결부의 손상은 나타나지 않았다. 또한 정적실험을 수행하여 연결부의 거동과 설계식의 적용성을 평가하고, 극한하중 상태에서의 구조적 성능과 정적강도 등을 평가하였다. 프리캐스트 바닥판 PSC 합성거더 교량은 사용하중상태에서 균열에 대해 2.08의 안전율을 나타냈으며, 파괴 시 충분한 극한내력과 연성거동을 나타냈다. 수평전단 설계식을 프리캐스트 바닥판 PSC 합성거더 교량의 수평전단 설계에 적용할 경우 사용성 및 구조적 안전성에 문제가 없는 경제적이고 신속한 형태의 교량을 시공할 수 있을 것으로 판단된다.

FC-BGA C4 bump의 신뢰성 평가에 따른 파괴모드 연구 (The Effect of Reliability Test on Failure mode for Flip-Chip BGA C4 bump)

  • 허석환;김강동;장중순
    • 마이크로전자및패키징학회지
    • /
    • 제18권3호
    • /
    • pp.45-52
    • /
    • 2011
  • Flip Chip Ball Grid Array (FCBGA) 패키지의 솔더조인트 신뢰성을 평가하기 위한 방법으로는 다이 충격법, 다이 전단법, 3점 굽힘법, 열충격법 등이 활용된다. 본 연구에서는 솔더 접합부의 주요 고장메카니즘인 취성파괴를 확인하기 위한 방법으로 리플로우 상태, $85^{\circ}C$/85%RH 처리, $150^{\circ}C$/10hr 에이징의 처리한 후, 4가지 평가법으로 평가를 진행하여 파단모드를 분석하였다. 본 연구결과에서는 다이 충격법과 다이 전단법의 Good joint rate (GJR, %)는 리플로우 상태와 $85^{\circ}C$/85%RH처리에서 각각 89~91%와 100% 였으며, $150^{\circ}C$/10hr 에이징에서는 66%와 90%를 나타내었다. 3점 굽힘법과 열충격법의 GJR(%)는 3종류 샘플에서 모두 100%를 나타내어 변별력이 없었다. C4 솔더접합부의 신뢰성 평가법에 따른 GJR(%)의 변별력을 확인할 수 있는 방법은 die shock 과 die shear test였다.

초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가 (Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete)

  • 강재윤;정우태
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5015-5020
    • /
    • 2015
  • 기존에 제안된 Perfobond rib connector의 강도평가식은 압축강도가 약 50 MPa 이하의 콘크리트 강도 범위에 대한 Push-out test의 결과로 유도된 것으로서, 압축강도 80 MPa 이상의 초고성능 콘크리트에 대한 전단 연결재 성능 평가를 위하여 Perfobond rib 연결재의 전단강도를 파악하기 위한 Push-out test를 수행하였다. Perfobond rib connector의 제작변수는 관통홀의 지름 및 개수이며, 강섬유가 혼입된 180 MPa의 콘크리와 강섬유를 혼입하지 않은 압축강도 80 MPa의 콘크리트를 적용하여 콘크리트 강도 변화에 대한 전단강도 변화를 검토하였다. 실험결과, 콘크리트 강도와 홀의 개수가 증가함 따라 전단강도가 증가하며, 다웰 효과에 의한 전단강도 증가율도 큰 것으로 나타났다. 기존에 다른 연구자들이 제안한 강도식으로 계산된 예측치와 비교한 결과, 실험값은 Oguejiofor & Hosain[2]이 제안한 강도식에 근접한 결과를 보였다.

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.