• Title/Summary/Keyword: Shear Test

Search Result 4,458, Processing Time 0.03 seconds

An Experimental Study on In-Plane Shear Strength of the Interface between Half PC Plate and Cast-in-Place Concrete Plate (하프 PC판과 후타설콘크리트 접합면의 면내전단강도에 관한 실험적 연구)

  • 신동원;고만영;이동우;김용부
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.513-518
    • /
    • 1998
  • In Half Precast Concrete Method, such as composite slab and composite wall, Interface between half PC plate and cast-in-place concrete is occurred. And this interface endure lastly in-plane shear which is occurred by external force. Therefore, test was executed to study in-plane shear strength of interface between half PC plate and cast-in-place concrete. In this test, Experimental parameters are finishing condition of the interface, cohesion of concrete, existence and nonexistence of re-bar truss, and angle and direction of lattice of re-bar truss. Comparing and analyzing experimental results, conclusions are obtained as follows. (1) In-plane shear strength of wide interface in composite plate is more affected by the roughness of interface than re-bar truss. And cohesion of concrete contribute to increasing in-plane shear strength. Therefore it seems that the interface should be roughen and kept clean to improve in-plane shear strength. (2) It seems that shear friction equation in ACI code can be sagely available for design of in-plane shear of composite plate.

  • PDF

Experimental Investigation of Shear Modulus of a Core in a Metallic Sandwich Plate with a Truss Core (트러스형 금속 샌드위치 판재에서 심재의 전단특성계수의 실험적 결정)

  • Jung, Chang-Gyun;Seong, Dae-Young;Yang, Dong-Yol;Moon, Kyung-Je;Ahn, Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.67-73
    • /
    • 2007
  • A sandwich plate with a truss core is composed of two face sheets and a pyramidal truss core between face sheets. This paper shows how to estimate the shear modulus of a truss core, experimentally. To determine the shear modulus of truss cores, 3-point bending tests are performed. For tests, metallic sandwich beams with truss cores are fabricated. Two kinds of truss cores are tested to investigate the shear modulus. Each test is repeated under different widths in order to increase accuracy. As a result, the shear modulus of sandwich beam is properly calculated. The deflection of a sandwich beam with a truss core by shear deformation takes the major contribution of the total deflection and the shear modulus of sandwich beam should be considered whenever it is designed.

Structural Performance Evaluation of Reinforced Concrete Shear Walls with Various Connection Type Under Load Reversals. (반복하중을 받는 철근콘크리트 전단벽체의 접합방식에 따른 구조성능 평가)

  • 신종학;하기주;권중배;전찬목
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.513-518
    • /
    • 1997
  • In this study, nine reinforced concrete infilled frames involved bare frames were tested during vertical and cyclic loads simultaneously. This test programs were carried to investigate the horizontal strength and the crack propagation in variance with hoop reinforcement ratio. All specimens were modeling in one-third scale size. In this experimental program structural performance of reinforced concrete shear wall were focus at connection types. Based on the test results, the following conclusions are made. In the boundary column member of reinforced concrete shear wall, increasing the ratio of hoop bar in two or three times, in the fully babel type, the shear and horizontal strength of specimens were increased 1.1-1.2 times than that of fully rigid frame. And infilled shear wall specimen were increased 1.17-1.27 times than that. Fully rigid babel type shear wall specimens were increased 5.7~8.0 times, and infilled shear wall specimens were increased about 4.0~5.6 times than that of infilled shear wall specimens.

  • PDF

A Study on the Rational Shear Model by interpretation of Stuttgart Beam Shear Test (Stuttgart 콘크리트 보 전단실험의 재해석을 통한 합리적 전단모델 연구)

  • 김우;모귀석;정제평
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.884-889
    • /
    • 2003
  • Based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subject to combined shear and moment loads, the shortcomings of present truss models are discussed. The core of the theory is that a new perspective on the shear strength can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be designed using the simple truss having curved compression chord, while the beam action between the two chords can be modeled using a parallel chord truss with MCFT or RA-STM. The compatibility of deformation associated to the two action is taken into account by employing a characteristic factor a. The new model was examined by the Stuttgart beam shear tests, and the results show that the present approach provides good estimates of stirrup contribution and concrete contributions.

  • PDF

Shear Rate Effect on Undrained Shear Behavior of Holocene Clay (자연 퇴적 점성토의 비배수 전단강도에 미치는 전단 속도의 영향)

  • Jung, Min-Su;Chae, Jong-Gil;Shibuya, Satoru
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1181-1192
    • /
    • 2008
  • A laboratory investigation was carried out into effects of strain rate on undrained shear behavior of Holocene clay underneath Kobe Airport with an objective to evaluate the factor of safety of the retaining structure built on it. It was examined in a series of triaxial compression and extension tests performed using different rate of axial straining. A comparative compression test in which the strain rate was changed in steps was also carried out. Similar tests were performed in constant-volume direct shear box (DSB) test. And, the deformation characteristics of the clay were also examined in order to evaluate the variation of stiffness during undrained shearing. It was found that the undrained strength increased with not only the shear rate but also the consolidation period. ISOTACH properties seemed a key to govern the undrained shear behavior.

  • PDF

An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment (콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구)

  • Kim, Min-Seong;Lee, Seung-Yup;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

Behavior of PSC Composite Bridge with Precast Decks (프리캐스트 바닥판 PSC 합성거더 교량의 거동)

  • Chung, Chul Hun;Hyun, Byung Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.873-880
    • /
    • 2006
  • PSC composite bridge with precast decks which was designed by the proposed horizontal shear equation was fabricated. Fatigue test was performed to evaluate the endurance of shear connection and the behavior of PSC composite bridge. After all the fatigue loading were applied, no crack and no residual slip were occurred. The flexural stiffness of PSC composite bridge was maintained the initial value, and demage of shear connection was not occurred. To verify the applicability of horizontal shear equation and shear connection detail and to evaluate the strength of PSC composite bridges, static test was also executed. PSC composite bridges with precast decks had 2.08 safety factor which was the ratio of crack to serviceability load and showed ductile behavior after ultimate load. Test results showed that the proposed design equation of the shear connection gave reasonable horizontal shear connection design. Fast and easy construction would be achieved using the suggested precast system.

The Effect of Reliability Test on Failure mode for Flip-Chip BGA C4 bump (FC-BGA C4 bump의 신뢰성 평가에 따른 파괴모드 연구)

  • Huh, Seok-Hwan;Kim, Kang-Dong;Jang, Jung-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.3
    • /
    • pp.45-52
    • /
    • 2011
  • It is known that test methods to evaluate solder joint reliability are die shock test, die shear test, 3points bending test, and thermal shock test. The present study investigated the effects of failure mode on 3 types (as-reflowed, $85^{\circ}C$/85%RH treatment, and $150^{\circ}C$/10hr aging) of solder joints for flip-chip BGA package by using various test methods. The test methods and configurations are reported in detail, i.e. die shock, die shear, 3points bending, and thermal shock test. We focus on the failure mode of solder joints under various tests. The test results indicate that die shock and die shear test method can reveal brittle fracture in flip-chip ball grid array (FCBGA) packages with higher sensitivity.

Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete (초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가)

  • Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.5015-5020
    • /
    • 2015
  • Push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action.

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.