• 제목/요약/키워드: Shade

검색결과 1,033건 처리시간 0.031초

Effects of 3 different light-curing units on the physico-mechanical properties of bleach-shade resin composites

  • Azin Farzad;Shahin Kasraei;Sahebeh Haghi;Mahboubeh Masoumbeigi;Hassan Torabzadeh;Narges Panahandeh
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.9.1-9.11
    • /
    • 2022
  • Objectives: This study investigated the microhardness, flexural strength, and color stability of bleach-shade resin composites cured with 3 different light-curing units. Materials and Methods: In this in vitro experimental study, 270 samples were fabricated of bleach and A2 shades of 3 commercial resin composites (Point 4, G-aenial Anterior, and Estelite Sigma Quick). Samples (n = 5 for each trial) were cured with Bluephase N, Woodpecker LED.D, and Optilux 501 units and underwent Vickers microhardness and flexural strength tests. The samples were tested after 24 hours of storage in distilled water. Color was assessed using a spectrophotometer immediately after preparation and 24 hours after curing. Data were analyzed using 3-way analysis of variance and the Tukey test (p ≤ 0.001). Results: Samples cured with Optilux exhibited the highest and those cured with LED.D exhibited the lowest microhardness (p = 0.023). The bleach shade of Point 4 composite cured with Optilux displayed the highest flexural strength, while the same composite and shade cured with Sigma Quick exhibited the lowest (p ≤ 0.001). The color change after 24 hours was greatest for the bleach shade of G-aenial cured with Bluephase N and least for the A2 shade of Sigma Quick cured with Optilux (p ≤ 0.001). Conclusions: Light curing with polywave light-emitting diode (LED) yielded results between or statistically similar to those of quartz-tungsten-halogen and monowave LED in the microhardness and flexural strength of both A2 and bleach shades of resin composites. However, the brands of light-curing devices showed significant differences in color stability.

육안과 분광 측정기를 이용한 자연 치아의 색조비교분석 (Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods)

  • 김범석;신수연;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.443-454
    • /
    • 2008
  • 도재 수복물 제작을 위해 자연치아의 색조를 분석하는 방법으로는 색견본 (shade guide)을 이용하는 시각적인 방법과 기계를 이용하는 방법이 있다. 그중 통상적인 육안 관찰을 통해 색조를 선택하는 것은 임상에서 가장 많이 이용되고 있는 방법이기는 하나 주관적이며 일관되지 않은 결과로 신뢰성의 문제가 제기되었으며 자연치의 색조는 매우 다양하여 같은 치아라 할지라도 부위별로 다양한 색조를 가지기 때문에 단순히 shade tab을 이용한 색조 비교만으로는 정확한 치아의 색조 특성을 나타내는 것이 불가능한 것으로 알려져 있다. 한편 지속적인 기술발달로 computer color matching system, 치과용 비색계, 분광 측정기 등의 기계를 이용한 치아 색조 측정 방법이 이의 대안으로 제시되고 있다. 기계를 이용한 방법은 색조 선택에 있어 객관적이며, 재현성이 있는 정확한 정보를 술자에게 제공한다. 이에 본 연구에서는 광원, 개인, 술자의 숙련도에 따라 육안과 기계를 통한 관찰 시 치아 색조 선택의 정확성을 확인하기 위한 실험을 시행하였다. 첫 번째 실험에서는 치과대학병원 전공의인 1명의 검사자가 10명의 피검자를 오전, 정오, 오후 각 3번의 측정을 통해 시간대별 자연광하에 육안, 기계 측정의 색조 선택 정확성을 분석하였다. 두 번째 실험에서는 5명의 치과대학병원 전공의와 5명의 치과대 학생, 총 10명의 검사자가 10명의 피검자를 정오에 육안, 기계 관찰을 통해 개인차에 따른 정확성을 실험하였다. 세 번째 실험에서는 두 번째 실험의 결과를 5명의 치과대학 전공의, 5명의 치과대학생 군으로 나누어 숙련도에 따른 육안, 기계 색조 선택의 정확성을 분석하였다. 실험 결과, 첫 번째 실험에서는 기계 측정 결과가 육안 측정보다 통계적으로 유의한 차이를 보이며 (P < .05) 색조 선택의 정확성을 나타내었고, 두 번째 실험에서 역시 기계 측정시 개개인의 육안 측정에 의한 색조 선택 값에 비해 재현성 및 정확성이 높았으며 통계적으로 유의한 차이를 보였다 (P < .05). 세 번째 실험에서 이전 실험의 결과를 숙련자, 비숙련자 군으로 나누어 분석한 결과 군 내 기계 측정값이 육안 관찰값보다 숙련도에 상관없이 정확도가 높으며 통계적으로 유의한 차이를 보였다 (P < .05). 하지만 군 간 육안, 기계 측정값을 비교 시 통계적으로 유의한 차이를 보이지 않아 치아 색조를 육안, 기계 측정할 때 술자의 숙련도가 큰 영향을 미치지 않음을 알 수 있었다. 따라서 기계를 이용하는 치아 색조 측정 방법이 색견본을 이용하는 시각적인 방법에 비해 더 정확하기는 하지만 어느 정도의 측색 오류를 고려해야하며 수복물 제작 시 정확한 재현과 효과적인 정보 전달을 위해 시각적인 방법과의 병행이 필요할 것으로 사료된다.

Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가 (OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS)

  • 박수정;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.356-364
    • /
    • 2007
  • 본 연구에서는 현재 임상에 사용되고 있는 opaque shade 복합레진의 opacity와 배경색 차단 능력을 평가하였다. 24개의 배경 시편 (직경 5.5 mm, 두께 3 mm)을 Tescera ATL Root dentin Mustard로 제작하고 배경판 레진 상에 7종의 opaque shade 복합레진 (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, Metafil Flo)과 통상적인 복합레진인 Estelite Sigma를 3.0 mm 적층 수복하였다. 적층된 opaque shade 복합레진의 표면 색상을 측정한 후, 적층한 두께가 0.5 mm가 될 때까지 0.3 mm 간격으로 적층된 면을 연마하면서 각 두께에서의 표면 색상을 측정하였다. 연마 후 각 두께에서 측정된 opaque shade 복합레진의 표면 색상과 적층 전의 배경판 색상, 그리고 연마전의 표면 색상 간의 색차를 계산하여 두께에 따른 배경색 차단 능력을 평가하였다. 또한 1 mm 두께의 시편을 제작하고 opacity를 측정하여 다음의 결과를 얻었다. Opaque shade 복합레진의 opacity는 Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, Esthet-X 순으로 감소하였다 (p < 0.05). Opaque shade 복합레진의 두께의 감소에 따라 $L^*$ 값은 감소하는 양상을, $a^*$ 값은 증가하는 양상을 보였다. 연마 전 표면 색상과 연마 후 각 두께에서의 색차 (${\Delta}E^*$)는 Clearfil ST 군은 모든 군에서, Metafil Flo 군은 1.0 mm 이상에서 3 이하의 색차를 보였다. 배경 색상에 대한 각 opaque shade 복합레진의 색차는 모든 두께에서 10 이상의 색차를 보였으며, Clearfil ST와 Metafil Flo가 가장 큰 색차를 보였다 (p < 0.05). 현재 임상에 사용되고 있는 opaque shade 복합레진들은 제조사에 따라 서로 다른 opacity와 색상을 가진다. 따라서 재료의 선택에 있어 적용하고자 하는 병소의 특성에 따라 opaque shade 복합레진의 opacity와 색상에 대한 충분한 고려가 필요하리라 사료된다.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

Perception and satisfaction of the face and the need for aesthetic dental treatment in the college students

  • Lee, Seung-Hun
    • 한국치위생학회지
    • /
    • 제17권1호
    • /
    • pp.89-98
    • /
    • 2017
  • Objectives: The purpose of the study is to investigate the perception and satisfaction of faces and the need for aesthetic dental treatments in college students. Methods: A self-reported questionnaire was completed by 247 college students in Suncheon from August 29 to September 2, 2016. The questionnaire consisted of satisfaction of face (16 items), perception of the face (7 items), need for aesthetic dental treatment (3 items), and general characteristics of the study subjects (8 items). Tooth shade was measured using a shade guide (VITA classical shade guide, VITA North America, Chicago, USA). Data was analyzed using t test, ANOVA, and post hoc $Scheff{\acute{e}}$ test. Results: The students were satisfied with eye, mouth corner, and lip, but they were not satisfied with tooth shade, bilateral symmetry of face, and angle of jaw. The students tended to be concious of perception of others. Their most common tooth shade was orange and yellow. They preferred to have a brighter tooth color. Conclusions: To satisfy the needs of patients, it is important to understand the perception and satisfaction of face and the need for aesthetic dental treatment.

참억새 및 수크령의 광도차에 따른 생육변화 및 가스교환에 미치는 영향 (Effect of Different Light Intensities on the Growth and Leaf Gas Exchanges in Miscanthus sinensis and Pennisetum purpurascens)

  • 곽혜란;이종석
    • 한국환경복원기술학회지
    • /
    • 제7권1호
    • /
    • pp.110-115
    • /
    • 2004
  • This experiment was conducted to investigate the effect of light intensities on the growth responses, carbohydrate contents and the characteristics of leaf gas exchange in Miscanthus sinensis and Pennisetum purpurascens. The plant height and leaf length were increased to about 30% in the sun. However, those were reduced severely in the shade, and leaf necrosis was also observed. The representative growth index and the dry weight of 2 species were 50% higher than shade and the rate was reduced according to the decrease of light intensities. Total carbohydrate contents showed very similar changes to that of dry weight. However, any notable influences were observed at above the light intensities of 250~500${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in the half shade. The size of spikes and the earliest spiking appeared in the sun and the spike color was decolorized as decreased in light intensities, irrespective of species. Photosynthetic rate of 2 species was 2 times higher in the sun than those in the shade, and it showed the typical photoresponses of sun plant. Stomatal conductances and intercelluar $CO_2$ concetration showed similar changes to that of photosynthetic rate. On the contrary, vapor pressure deficit was increased more in the shade than in the sun.

SOME ASPECTS OF THE CANADIAN CULTURE OF GINSENG (PANAX QUINQUEFOLIUS L.), PARTICULARLY THE GROWING ENVIRONMENT

  • Proctor J.T.A
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1980년도 학술대회지
    • /
    • pp.39-47
    • /
    • 1980
  • The harvesting and export of Canadian ginseng from the cool, shady hardwood forests of southern Canada can be traced to 1796. Because of its high dollar value and diminishing woodland supplies it was decided in 1896 that it should be cultivated under wood lath screens. Present day economics dictate changes in production techniques to allow for a decreasing supply of expensive labour. Traditional wooden lath screens have a surface area of wood of 70 per cent and permit light penetration of only about 18 per cent. Experimental woven black polypropylene shade has an estimated surface area of 72 per cent and permits light pentration of about 28 per cent. While differences in air and leaf temperatures under the two shade structures can be measured it is doubtful if these are great enough to cause differences in plant growth under the two structures. Shade grown ginseng had a low fresh and dry weight and total chlorophyll content (ratio of a to b was 3 to 1) comparable to other shade species. There was no differences in fresh and dry weight and chlorophyll content of leaves from plants grown under the two shade structures. Maximum net photosynthesis of leaves was 0.175 g $CO_2\;m^{-2}\;hr^{-1}$ and light saturation level was about $200{\mu}E\;m^{-2}\;s^{-1},$ or about 10 per cent of full sunlight.

  • PDF

몇 가지 자생 지피식물의 차광에 따른 생장반응 (Growth Reaction of Some Ground Cover Plant in Korean Native Greening according to Shading Levels)

  • 김귀순;이정식
    • 화훼연구
    • /
    • 제17권2호
    • /
    • pp.75-80
    • /
    • 2009
  • 본 연구는 음지에서 잘 자라는 자생 지피식물 선발을 위해 7종의 자생식물을 대상으로 광 조건을 달리하여 생장반응을 조사하였다. 비비추는 자연광의 60% 차광에서 가장 좋은 생장을 보였으며, 맥문동은 90% 차광에서 생육이 매우 좋았다. 관중은 60% 차광에서 생육이 가장 우수 하였으며, 대사초는 40% 차광에서 초장과 초폭이 신장이 좋았고 엽수도 많았다. 비비추, 맥문동, 관중 및 수호초는 차광율이 높을수록 엽록소 함량이 점차 증가되었으며, 맥문동은 완전음지나 자연광에서는 개화되지 않았다.

대두내륭성계통의 선발에 관한 연구 (Studies on the Screening for Shade Tolerance in Soybean)

  • 권신한;원종락
    • 한국작물학회지
    • /
    • 제24권3호
    • /
    • pp.51-57
    • /
    • 1979
  • 대두내륭성계통의 효율적인 Screening 방법을 확립코저 국내재래종을 재료로 여러 생육기별로 15일간 그늘처리를 하여 초장, 주당마디수, 가지수, 협수와 100입중 및 수량을 조사하였다. 1. 초장은 2차처리구인 7월 21일부터 8월 4일 기간의 그늘처리에 의해 도장현상을 보였고 주당마디수와 가지수, 입중 등은 그늘처리의 영향을 거의 받지 않았다. 2. 주당협수와 수량은 모두 1차 처리구인 7월 6일부터 7월 20일 기간외는 무처리에 l해 감소되고 이때의 계통간 차이도 컸다. 3. 내륭성계통의 Screening을 위해서는 개화말기부터 결협기에 그늘처리를 하고 주당협수를 선발지표형질로 사용할 수 있을 것 같다.

  • PDF

간접 수복용 복합레진의 Incisal 색상 적층 두께에 따른 표면 색상 및 색차의 평가 (The evaluation of color and color difference according to the layering placement of Incisal shade composites on the body composites of the indirect resin restoration)

  • 박수정;이한영;나명윤;장훈상;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.37-49
    • /
    • 2011
  • 연구목적: 간접 복합레진 수복은 직접 수복의 여러 문제점들을 극복하는 대안으로 적용 빈도가 증가하고 있지만 간접 수복물의 특성상 치아 삭제 전 술자에 의해 결정된 색상을 기공 과정 동안 재현해야하기 때문에 기준이 되는 shade guide와 실제 간접수복용 레진간의 색상의 일치성이 요구되며, 치아의 다양한 표면의 광학적 특성을 부여하기위한 법랑질 특성의 복합레진의 광학적 특성에 대한 정보가 필요하다. 연구 재료 및 방법: 본 연구에서는 이러한 간접 복합레진 수복재료의 색상 특성을 알아보기 위해 간접수복용 레진인 Tescera ATL (Bisco, USA)의 Body composite의 색상과 동일한 색상 기호의 Vitapan shade guide 간의 색차를 알아보고, Body composite와 Incisal composite의 적층 수복 시 색상 변화 양상을 분석하고자 시행하였다. 직경 5 mm, 두께 3 mm의 원기둥형 Body composite 시편을 각 색상 당 9개씩 제조사의 지시에 따라 제작하고, 표면 연마 후 분광광도계(NF999, Nipon Denshuku, Japan)을 이용해 색상(CIE $L^*a^*b^*$)을 측정하고 Vitapan shade guide의 색상을 측정하였다. 색상 측정이 끝난 Body composite에 9 색상의 Incisal composite를 1 mm 두께로 적층하고 중합, 연마 한 후 적층면의 색상을 측정하였으며, Incisal composite를 0.5 mm 두께만큼 연마한 후 다시 색상을 동일한 측정 기기로 측정하였다. 결과: Tescera ATL과 Vitapan shade guide의 동일한 색상 간에 최소 6.88, 최대 12.80의 큰 색차(${\Delta}E^*$)를 보였으며, 모든 색상에서 시각적으로 확연한 차이를 보였다. 모든 색상의 Body composite에서 적층한 Incisal composite의 색상에 관계없이 Incisal composite의 두께가 두꺼워 질수록 Body composite 과의 색차가 증가하였다(p < 0.05). 또한 $L^*$값과 $b^*$값은 Incisal composite의 두께가 두꺼울수록 감소하는 양상을 보인 반면 $a^*$값은 큰 변화를 보이지 않았다. 결론: 이상의 결과로 Tescera ATL을 이용한 간접 복합레진 수복 시 색상 결정에 있어 기존의 shade guide의 사용은 부적절하며, 동일한 재료로 제작한 개별적인 shade guide가 필요하리라 사료되며, Incisal composite 적용 시 색상 변화에 대한 정확한 정보를 바탕으로 신중한 적용이 필요하리라 사료된다.