• Title/Summary/Keyword: Sewage samples

Search Result 212, Processing Time 0.024 seconds

Conversion of CODMn into TOC and Refractory Organic Matter Concentrations for Treated Sewage using Regression Equations (회귀식을 사용한 하수처리장 방류수 CODMn 농도의 총 유기탄소 및 난분해성 물질 농도 전환)

  • Lee, Tae-Hwan;Lee, Bomi;Hur, Jin;Jung, Myung-Sook;Kang, Tae-Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.969-975
    • /
    • 2010
  • Estimating the organic matter loadings from individual treated sewage has become important for establishment of effective management strategies to control refractory organic matter (R-OM) in watersheds. For this study, regression equations were constructed using treated sewage data to convert the chemical oxygen demand (COD) concentrations, which are mostly available from open database, into total organic carbon (TOC) and R-OM concentrations. Effluent samples were collected from five major sewage treatment plants (STPs) located upstream of the lake Paldang. Variations in the OM concentrations were not associated with either the location of the STP or the sampling season. The effluent investigated were characterized by higher ratio of R-OM with respect to biodegradable organic matter (B-OM) and higher presence of dissolved organic matters (DOM) versus particulate organic matter (POM). Compared to $COD_{Mn}$, $COD_{Cr}$ exhibited higher oxidation efficiencies and greater variations in the concentrations. The concentrations of $COD_{Mn}$ were positively correlated with dissolved organic carbon (DOC), total organic carbon (TOC), and R-OM concentrations. There was nearly no seasonal and annual variation in the regression equations between $COD_{Mn}$ and TOC or R-OM concentrations. The constructed regression equations for TOC and R-OM were $0.650({\pm}0.071){\times}COD_{Mn}+1.426({\pm}0.575)$ and $0.340({\pm}0.083){\times}COD_{Mn}+2.054({\pm}0.670)$, respectively. The established equations are expected to contribute to estimating OM loadings from the STPs into the lake Paldang and also to compensating for the deficiency of the data for effluent OM concentrations in STP.

Experimental Study on Hydrogen Sulfide Abatement in Sewage Odor Using Microbial Deodorants on the Market (시판용 미생물탈취제를 이용한 하수 악취 내 황화수소 저감에 관한 실험적 연구)

  • Park, Sang Jin;Kwon, Soo Youl
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.170-183
    • /
    • 2020
  • Objectives: This study was conducted to estimate a technology to reduce hydrogen sulfide (H2S) in sewage odor using microbial deodorant. Methods: After injecting five commercially available microbial deodorants into fresh sewage, the concentration of hydrogen sulfide over time was measured using the headspace method. H2S concentration in odor samples was measured using gas chromatograph/FPD. Calculated odor concentration and calculated odor intensity by H2S concentration remaining after treatment with microbial deodorant were evaluated theoretically. Results: The rate of H2S abatement by microbial deodorant differed depending on the experimental conditions and the type of deodorant, but it was found to range from 63 to 82%. Especially, two deodorants showed high H2S reduction rates of over 80% on average. However, based on the best deodorant, the theoretically calculated odor concentration by H2S after microbial deodorant treatment was 4,400 OUk, and the theoretical odor intensity was also rated at 4 degrees or higher. Conclusions: In conclusion, microbial deodorant is considered to have a relatively high effect on reducing H2S in sewage odor. However, even after treatment with microbial deodorant, calculated odor concentration and calculated odor intensity were relatively high. This is thought to be caused by other odorous substances besides H2S.

The Characteristics of Sludge Landfill Site in Nanjido (난지도 하수슬러지 매립지의 슬러지 성상분석)

  • Namkoong, Wan;Hwang, Seon Suk;Kim, Chul Soo;Yeun, Bum Han;Ryu, Bum Su
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.47-53
    • /
    • 1996
  • This study was carried out to estimate the amount and the characteristics of sewage sludge disposed of in the Nanjido sludge landfill site. Boring test was conducted to estimated the landfill volume and to get sludge samples to be analyzed. Total analysis and leaching test were performed to find the characteristics of sewage sludge. The Nanjido sludge landfill site had the surface area of $50,000m^2$ and the average depth of 15m. The estimated sludge volume was 600,000ton. Sewage sludge in Nanjido sludge landfill site was very stable. Results of total analysis of heavy metals indicated that the sludge could be classified as a non-hazardous waste according to the California state regulation. The sludge also could be used as compost based on compost quality criteria of foreign countries. Results of Korea Extraction Procedure showed that sewage sludge in Nanjido sludge landfill site was not a hazardous waste.

  • PDF

Pretreatment and Rapid Detection Methods for Wastewater-Based Epidemiology (하수역학 구축을 위한 시료 전처리 기술과 신속검출기술)

  • Lee Jai-Yeop;Lee Bokjin;Jesmin Akter;Ahn Chang Hyuk;Kim Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.1
    • /
    • pp.102-110
    • /
    • 2023
  • Wastewater Based Epidemiology (WBE) provides useful information not only on the use of illegal drugs in the community, but also on the presence of hygiene and health products and infectious pathogens in sewage facilities. As a consequence of the SARS-CoV-19 virus epidemic in 2019, monitoring the status of the infection is of utmost importance. SARS-CoV-19 was also detected in sewage, and the number and trend of infections in the community suggest that the application of the WBE system would be useful and appropriate. This study introduces a pre-treatment concentration method including viruses in sewage samples. A total of seven methods which were subdivided into methods for adsorption-extraction, ultra-filtration, PEG precipitation, and ultra-centrifugation, and the results for analyzing the recovery rates were included. Meanwhile, it is necessary to pay attention to rapid detection technologies which analyze infectious pathogens at the site of sewage facilities. These can include ELISA, FTIR, SERS, and biosensor based on the detection principle, and the characteristics, advantages, and disadvantages of each were summarized herein. If rapid detection technologies and accurate quantitative analyses are further developed, the use of sewage mechanics in response to pandemic viruses is expected to expand further.

Evaluation of Effectiveness of Concrete Coated with Bacterial Glycocalix under Simulated Sewage Environments (유사 하수환경에서 글라이코 캘릭스 코팅 콘크리트의 효율성 평가)

  • Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.97-104
    • /
    • 2020
  • The present study conducted mock-up tests under the simulated sewage environments to examine the practical significance and limitation of coating materials that were previously developed on the basis of the bacterial glycocalix as a protection of concrete structures exposed to microbiological and sulphate attacks. The variations of the compressive strength and mass of the concrete due to the sulphate attack were measured using cylinder specimens. The bacteria growth and glycocalix formulation were calculated from the samples extracted from the sewage pipes. The next generation sequencing analysis was also conducted for environmental damage assessment due to the use of Rhodobacter capsulatus in the simulated sewage environments. The mock-up tests revealed that the developed coating materials have a good potential in resisting the sulphate attack, indicating no reduction on compressive strength and mass of the coated concrete under the sewage environment. At the age of 91 days, the concentrations of viable bacteria and glycocalix measured from the hardened coating materials were 1.4×104cell/mL and 67.5mg/㎤, respectively. Moreover, harmful strains were not observed in the sewage water including glycocalix-coated concrete pipes. This implies that Rhodobacter capsulatus used in the coating materials does not influence negatively the microorganism cluster in the sewage environments.

Emission Characteristics of Odor Compounds from a Sewage Treatment Plant Near an Industrial Complex Area in Daegu City (대구시 산업단지 인근 하수처리장의 악취발생 특성)

  • Lee, Myeong-Sug;Kang, Dong-Hoon;Keum, Jong-Lok;Kwon, Byoung-Youne;Jo, Hang-Wook;Lee, Chan-Hyung;Kim, Eun-Deok;Lim, Ho-Jin;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • Objectives: This study evaluated the odor emission characteristics from a sewage treatment plant near an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2017 to December 2017 and analyzed for specified offensive odor substances. The odor quotient and the odor contribution were calculated. Results: Ammonia, methyl mercaptane, hydrogen sulfide, dimethyl sulfide, acetaldehyde, propionylaldehyde, toluene, xylene, and methylethylketone were detected in all samples for monitoring the specified odor compounds. The result of contribution analysis is that hydrogen sulfide made the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating their degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

A Study on Nonylphenol, Octylphenol, and Di (2-ethylhexyl)phthalate in Sewage Sludge (하수슬러지 중 Nonylphenol, Octylphenol, Di (2-ethylhexyl)phthalate 의 연구)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.451-458
    • /
    • 2002
  • Determination were performed for the presence of three common environmental endocrine disrupting compounds (EDC), namely nonylphenol (NP), octylphenol (OP), di (2-ethylhexyl)phthalate in sewage sludge from 67 wastes plants, using Soxhlet extraction and GC/MS-SIM. NP and DEHP were detected in almost every sludges but OP was not detected. The range and mean value for NP of all sludge samples were nd~593, $62{\mu}g/g$ dry and the two statistic values for DEHP of those were 13~4733, $1176{\mu}g/g$ dry respectively. DEHP content was 20 times greater than NP in sludges. Concentrations of NP and DEHP in sludge from individual area were increased as following order ; Jeolla South and North Province (Cheju) < Chungcheong South and North Province (Kwangwon) < Gyungsang South and North Province < Wide City < Kyunggi Province.

Effects of Coastal Environment by Discharge from the Sewage Treatment Plant (해안방류된 하수처리수가 해양환경에 미치는 영향)

  • Shin, Bumshick;Kim, Kyu-Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.127-133
    • /
    • 2020
  • Most sewage treatment plants located offshore are discharged to the shore either directly or through rivers. Therefore, the water quality of the treated water discharged from the sewage treatment plant affects the water quality of the river water discharged to the river and the ocean. In this study, field surveys and numerical simulations were conducted to investigate the effect of treated water from the sewage treatment plant adjacent to the coastal environment. As a result of analyzing the water quality and sediment quality with the samples collected from the river and the estuary where the treated water was discharged to understand the impact on the coast, the treated water discharged from the sewage treatment plant was discharged to the river without exceeding the design criteria. However, the water quality discharged to the shore through estuaries was more contaminated than treated water. The cause of water quality deterioration of coastal effluent is due to the sedimentation of estuary temporarily by longshore sediment sransport which appeared around the estuary, the occurrence of estuary obstruction, and the increase of stagnant time in the estuary. As it was released and discharged, it was analyzed to affect the water quality, water quality and marine life around the estuary. Therefore, in the case of the east coast where the longshore sediment transport is strong, when planning the sewage treatment facility discharged to the ocean, it is necessary to closely examine the water quality change of the river water in the treated water such as the river mouth occlusion by the longshore sediment transport.

The Impact of a Basic Environmental Facility Siting on Land Prices : A Case of Sewage Disposal Plant (환경기초시설의 입지가 지가에 미치는 영향 : 하수처리장을 사례로)

  • JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.170-180
    • /
    • 2017
  • This research analyzed the effect of a basic environmental facility siting on the difference in land prices using a case study of Jisan sewage disposal plant in Daegu metropolitan city. To do so, two buffer zones were generated around Jisan sewage disposal plant to 400m at an interval of 200m as a setback distance and 822 officially announced individual land prices were acquired from Korea Ministry of Land, Infrastructure and Transport(MOLIT). Paired samples t-test was performed to compare the mean difference in land prices before and after Jisan sewage disposal plant siting. Results show that the mean land price from each buffer zone was slightly increased after the siting and the difference was statistically significant. Also, the results indicate that the mean land price within 200m was lower than that between 200m and 400m before the siting while there was not different in the mean land price for both buffer zones after the siting. Because Jisan sewage disposal plant did not have a stench and a larger capacity and its surrounding areas were blended by commercial and residential uses, a sewage disposal plant siting had little effect on the fall in land prices unlike previous studies. The findings from this research will provide new reference data for local government and local people with conflicting views on the siting of a basic environmental facility.

Study on Mutagenicity of the Water from Chung-gye and Joong-rang Streams (청계천 및 중랑천의 돌연변이원성 조사)

  • Kim Young-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.2 no.2 s.2
    • /
    • pp.39-47
    • /
    • 1987
  • This paper is examine the mutagenic activities of the water samples from Chun-gye and Joong-rang streams in March, 1968. For this examination, adsorbed of mutagens by 'blue cotton' and Ames method using Salmonella typhimurium was used. The results were as follow; 1. The average revertant colonies of the Chun-gye stream on TA 98 was 120/plate and TA 100 was 267/plate. 2. The average revertant colonies of the Joong-rang stream on TA 98 was l06/plate and TA 100 was 407/plate. 3. Chun-gye and Joong-range streams showed about the same mutagenic activities. 4. The mutagenic activity of treated sewage was higher than of untreated sewage. It is considered that, among the influent materials with Zimpro oxidation fluid, human feces and urine increased mutagenic activities.

  • PDF