• 제목/요약/키워드: Series Operation

검색결과 1,274건 처리시간 0.039초

코일의 자기결합을 이용한 초전도 사고전류제한기의 동작특성 (Operational Characteristics of SFCL using Magnetic Coupling of Coils)

  • 임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.68-70
    • /
    • 2007
  • The operational characteristics of superconducting fault current limiter (SFCL) using magnetic coupling of coils were investigated. This SFCL consists of a high-Tc superconducting (HTSC) element and two coils with series or parallel connection on the same iron. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the resistance of HTSC element comprising this SFCL increased more than that of HTSC element's independent operation.

  • PDF

새로운 단상 3전위 인버터회로의 구성에 관한 연구 (A Study on Composition of A Novel Single Phase 3 Level Inverter Circuit)

  • 이종수;백종현
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권5호
    • /
    • pp.51-56
    • /
    • 1995
  • The transistors of single phase 3 level PWM Inverter compose output power transistors and neutral point clamping transistors, which are NPN transistors. Waveforms of driving signals for this are PWM waves for power transistors and period operating waves for neutral point clamping transistors, which signals made W-type modulation from rectangular and sine wave. The output power transistors operate at ON-time complementary and neutral point clamping transistors operate at OFF-time complementary respectively. Therefore, each transistors operate in half period at parallel. Characteristics of this inverter circuit is parallel switching method about series switching method of general inverter. As modulation of 3 level drive signals made from full-wave rectifier of sine wave and rectangular wave, which are level wave about 3 level of complementary transistor inverter. So, this circuit composed complementary operation inverter of NPN transistors only compare with PNP-NPN complementary inverter, which have high power 3 level inverter of complementary operation.

  • PDF

마이크로그리드용 순간정전발생기의 순간정전모드 동작시 전류특성 해석 (Analysis of current characteristics of outage generator for microgrid in outage mode operation)

  • 이영호;민병호;노의철;김인동;전태원;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.130-132
    • /
    • 2008
  • This paper describes the current characteristics of outage generator for microgrid in outage mode operation. The outage can be generated with 3-phase voltage disturbance generator. The STS current becomes very huge during the first cycle of the outage, and the magnitude of the current depends on the time impedance, series transformer leakage inductance, interfacing reactor of PCS, and the maximum allowable PCS output current. The current and load voltage waveform are analysed through simulation.

  • PDF

5ft S-Band TT&C Antenna Test

  • Ahn Sang-il;Park Dong-Chul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.467-470
    • /
    • 2004
  • In early 2004, KARI developed 5ft S-Band TT&C antenna for especially KOMPSAT-2 operation in LEOP phase. This paper shows system features of 5ft S-Band antenna and its test result with KOMPSAT-l. Tracking test, command uplink test and telemetry downlink test were performed. Through tests, 5ft antenna was verified to be operational in uplink and downlink with KOMPSAT series. Due to its inherent wide 3dB beam-width of about 7deg at S-Band, this antenna system can be used very effectively even though orbital information is less accurate like LEOP and spacecraft safe mode.

  • PDF

만성 교약성 심낭염의 외과적 치료 (Surgical Treatment of Chronic Constrictive Pericarditis)

  • 장봉현;김규태
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.317-322
    • /
    • 1987
  • Records of 15 patients who underwent operation for constrictive pericarditis at this department from 1976 through 1984 were reviewed. All had hemodynamically significant pericardial constriction preoperatively, and pericardial disease was confirmed at operation. There were 12 males and 3 females in this series. Range of age varied from 7 years to 51 years. Clinical and histological study revealed granulomatous pericarditis compatible with the diagnosis of tuberculosis in 5 patients, non-specific chronic inflammatory changes in 6 patients and pyogenic pericarditis in 2 patients. Pericardiectomy was performed through a median sternotomy [11 cases] or bilateral anterior thoracotomy [4 cases]. The postoperative complications were observed in 4 patients. Low cardiac output was the most common complication [2 patients]. In 13 cases, excluding 2 operative deaths, preoperatively all were in New York Heart Association Class III or IV. At the time of discharge II [85%] were in Class I or II. 4 Cases were reoperated after original pericardiostomy and all resulted in marked improvement. Early surgical intervention is advisable in all patients in whom cardiac constriction is caused by either a thickened pericardium or a pericardial effusion before myocardial dysfunction occurs.

  • PDF

1차원 시스톨릭 어레이 프로세서를 이용한 고속 곡선 발생기에 관한 연구 (A Study on the High Speed Curve Generator Using 1-Dimensional Systolic Array Processor)

  • 김용성;조원경
    • 전자공학회논문지B
    • /
    • 제31B권5호
    • /
    • pp.1-11
    • /
    • 1994
  • In computer graphics since objects atre constructed by lines and curves, the high-speed curve generator is indispensible for computer aided design and simulatation. Since the functions of graphic generation can be represented as a series of matrix operations, in this paper, two kind of the high-speed Bezier curve generator that uses matrix equation and a recursive relation for Bezier polynomials are designed. And B-spline curve generator is designed using interdependence of B-spline blending functions. As the result of the comparison of designed curve generator and reference [5], [6] in the operation time and number of operators, the curve generator with 1-dimensional systolic array processor for matrix vector operation that uses matrix equation for Bezier curve is more effective.

  • PDF

채터모델링과 진단법에 관한 연구 (A Study on the Modeling and Diagnostics on Chatter in Endmilling Operation)

  • 김영국;윤문철;하만경;심성보
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.971-974
    • /
    • 2001
  • In this study, the static and dynamic characteristics of endmilling process was modelled and the analytic realization of chatter mechanism was discussed. In this regard, We have discussed on the comparative assessment of recursive time series modeling algorithms that can represent the machining process and detect the abnormal machining behaviors in precision endmilling operation. In this study, simulation and experimental work were performed to show the malfunctional behaviors. For this purpose, new recursive(RLSM) were adopted for the on-line system identification and monitoring of a machining process, we can apply these new algorithms in real process for detection of abnormal chatter. Also, the stability lobe of chatter was analysed by varying parameter of cutting dynamices in regenerative chatter mechanics.

  • PDF

SRM의 4상한 구동을 위한 전류제한 방식 (Current Limit Control for a Four-quadrant Operation of SRM Drive)

  • 안진우;강유정
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.285-291
    • /
    • 2003
  • 스위치드 릴럭턴스 전동기는 고출력, 고효율 및 직권전동기 구동특성 등으로 견인구동용으로 주목받고 있다. 그러나 전동기를 4상한 구동하기 위한 발전영역에서 제어는 쉽지 않다. 본 논문은 전류제한법에 의해 안정된 발전제동이 가능한 제어방식을 제안하였다. 전동기 구동시는 기준전류제한방식과 위상각 제어방식으로 속도제어를 행하고, 발전제동모드에서는 상전류가 발산하지 않는 조건을 산정하여서 이 값을 기준전류로 한 전류제한방식을 채택하였다. 시뮬레이션과 실험에 의해 제안한 방식의 타당성을 확인하였다.

PWM 콘버어터를 이용한 순시무효전력 보상장치의 동작해석 (A Study on the Operation Characteristics of a Reactive Power Copensator using PWM Converter)

  • 권기현;권순재;김철우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.310-312
    • /
    • 1989
  • From the viewpoint of an effective energy use, many method for reactive power compensation has been developed. Among of the reactive power compensation, this paper describes the relation of operation interpretation, filter, hysteresis width and switching time of current controlled PWM converter which has excellent reactive power compensation. This current controlled PWM convertor is excellent the view of reactive power compensation by current control method using hysteresis comparator method, but is required element of high response characteristics. Therefore this paper offers the series of data for system considering switching characteristics of switching element.

  • PDF

선반가공시 채터 모델링과 분석에 관한 연구 (A Study on the Modeling and Analysis of Chatter in Turning Operation)

  • 윤문철;조현덕;김성근;김영국;조희근
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.76-83
    • /
    • 2001
  • In this study, the static and dynamic characteristics of turning process was modelled and the analytic realization of regen-erative chatter mechanism was discussed. In this regard, we have discussed on the comparative assessment of recursive times series modeling algorithms that can represent the machining process and detect the abnormal machining behaviors in precision turning operation. In this study, simulation and experimental work were performed to show the malfunction behaviors. For this purpose, new Recursive Extended Instrument Variable Method(REIVM) was adopted for the on-line system identification and monitoring of a machining process. Also, we can apply REIVE algorithms in real process for the detection of chatter frequency and dynamic property and analyze the stability lobe of the system by changing a parameter of cutting dynamics in regenerative chatter mechanics, if it is stable or unstable, Also, The stability lobe of chatter was analysed.

  • PDF