과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

영상회로를 이용한 병행 송전선로에서의 고장점 추정 알고리즘 (Fault Location Algorithm in Parallel Transmission Line Using Zero Sequence Network)

  • 박홍규;이재규;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.282-284
    • /
    • 1999
  • This paper presents an accurate algorithm for fault location of a single phase to earth fault on a two-parallel transmission line using only one-terminal data. It is impossible to calculate the accurate fault distance, because of the unknown fault resistance and fault current at the fault point. The faulted line circuit and the zero-sequence circuit of two-parallel line are used as a fault location model, which the source impedance of the remote end is not involved. The algorithm can eliminate the effect of load flow and the fault resistance in calculating the fault location.

  • PDF

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.245-247
    • /
    • 2003
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk for mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel zone 3 scheme based on combining the steady-state components(i.e. 60Hz) and the transient components(TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

  • PDF

구조물 손상 탐지를 위한 경 방향 모드 압전 오실레이터 센서 개발 (Development of a Lateral Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 노용래;김동영
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 논문에서는 사회기반시설의 손상탐지를 위한 경 방향모드 압전 오실레이터의 가능성을 연구하였다. 경 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 경 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기 시키며, 그 결과로 구조물의 공진 주파수가 변화하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화 시키면서, FEM해석과 실험을 통해 경 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

A Novel Algorithm for Fault Classification in Transmission Lines Using a Combined Adaptive Network and Fuzzy Inference System

  • Yeo, Sang-Min;Kim, Chun-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.191-197
    • /
    • 2003
  • Accurate detection and classification of faults on transmission lines is vitally important. In this respect, many different types of faults occur, such as inter alia low impedance faults (LIF) and high impedance faults (HIF). The latter in particular pose difficulties for the commonly employed conventional overcurrent and distance relays, and if undetected, can cause damage to expensive equipment, threaten life and cause fire hazards. Although HIFs are far less common than LIFs, it is imperative that any protection device should be able to satisfactorily deal with both HIFs and LIFs. Because of the randomness and asymmetric characteristics of HIFs, their modeling is difficult and numerous papers relating to various HIF models have been published. In this paper, the model of HIFs in transmission lines is accomplished using the characteristics of a ZnO arrester, which is then implemented within the overall transmission system model based on the electromagnetic transients program (EMTP). This paper proposes an algorithm for fault detection and classification for both LIFs and HIFs using Adaptive Network-based Fuzzy Inference System (ANFIS). The inputs into ANFIS are current signals only based on Root-Mean-Square (RMS) values of 3-phase currents and zero sequence current. The performance of the proposed algorithm is tested on a typical 154 kV Korean transmission line system under various fault conditions. Test results demonstrate that the ANFIS can detect and classify faults including LIFs and HIFs accurately within half a cycle.

구조물 손상 탐지를 위한 두께 방향 모드 압전 오실레이터 센서 개발 (Development of a Thickness Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 김동영;노용래
    • 한국음향학회지
    • /
    • 제26권2호
    • /
    • pp.95-101
    • /
    • 2007
  • 본 논문에서는 구조물의 손상탐지를 위한 두께 방향 모드 압전 오실레이터의 가능성을 연구하였다. 두께 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 두께 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기시키며, 그 결과로 구조물의 공진 주파수가 변하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화시키면서, FEM해석과 실험을 통해 두께 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

바이오센서 개발을 위한 음향 브래그 반사층을 가지는 체적탄성파 공진기의 공진특성 분석 (Analysis of Resonance Characteristics of Bulk Acoustic Resonator with Acoustic Bragg Reflector for Biosensor Development)

  • 김희영;김기복;하태훈;김용일;이진민;김만수
    • Journal of Biosystems Engineering
    • /
    • 제34권4호
    • /
    • pp.260-268
    • /
    • 2009
  • As a basic study to develop a high sensitive biosensor using film bulk acoustic resonator, the mathematical model for analyzing the resonance characteristics of bulk acoustic resonator with acoustic Bragg reflectors was investigated. The simulation results due to the number of acoustic Bragg reflectors with low and high acoustic impedance materials were compared with the experimental results for 1, 2.25 and 5 MHz of PZT based bulk acoustic resonators with various acoustic Bragg reflectors. At the fabricated bulk acoustic resonator with an odd number of acoustic Bragg reflectors, low and high acoustic impedance materials in sequence under the bottom electrode showed better resonance characteristics than even number of acoustic Bragg reflectors. The changes of resonance frequencies due to the increase of number of acoustic Bragg reflectors by simulation and experiment, respectively showed approximately similar tendency but some differences in input impedance between the experiment and simulation were found. The derived mathematical model for describing the resonance characteristics of the bulk acoustic resonator with acoustic Bragg reflector will be available for analyzing the design parameters for development of biosensor using bulk acoustic resonator.

전력선 통신을 이용한 plant 감시 제어 시스템 (Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System)

  • 서민상;성석경;안병규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

퍼지추론 시스템을 이용한 지중송전계통 보호용 디지털 거리계전 알고리즘 개발 (Development of Digital Distance Relay Algorithm Using Fuzzy Inference System on Underground Power Cable Systems)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.502-503
    • /
    • 2006
  • If the fault occurs on the underground Power cable system, the fault current on the sheath has the influence on all sections because it's returned through earth at the directly grounded point and operation point of SVL(Sheath Voltage Limiter) at joint box. Therefore, the earth resistance and the operation of SVL have an effect on the zero-sequence current. Then the impedance between relaying point and fault point is Increased. That causes the overreach of distance relay. For these reasons, the distance relay algorithm for protecting of the underground power cable systems was developed. It effectively advance the errors using ACI(Advanced Computing Intelligence) technique. In this algorithm, the optimization was performed by fuzzy inference system and genetic algorithm.

  • PDF