• Title/Summary/Keyword: Separation rate

Search Result 1,380, Processing Time 0.026 seconds

Text line separation in handwritten address image using partial projection technique (부분 투영기법을 이용한 필기체 주소 영상에서의 문자열 분리)

  • 정선화;남윤석
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.31-34
    • /
    • 2003
  • In this paper, we describe a method for separating text lines in handwritten Korean address images. The most remarkable feature of the proposed method is to use a modified projection technique. named a partial projection technique. A projection based text line separation method which projects the whole address image in horizontal direction to find split points for text line separation cannot avoid failing separation in case of images with a little skew or overlap between vertically neighboring text lines. To overcome this problem, we have introduced a partial projection technique which splits an address image into a few partial address images to be equal width and then project them each horizontally. The experiment done with 989 handwritten Korean address images extracted from live mails shows the superiority of the proposed method. The correct text-line separation rate fir the testing images was about 91.5%.

  • PDF

Separation of PET and PS with Air Separation

  • Nakazawa, Hiroshi;Kudo, Yasuo;Sato, Hayato
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.727-729
    • /
    • 2001
  • The air separation of PET (Polyethylene terephthalate) and PS(Polystyrene) was carried out by taking advantage of the different abrasive resistance of two plastics. PET bottles and PS packages were shredded to small square pieces $(5{\times}5mm)$. Both plastic shreds were treated by a shear-type crusher. The PET shreds were bent and twisted by the crush so that they were blown up easily, but the PS shreds were not. After the crush of mixture of both plastics, air separation experiments were carried out using four types of air separators. The number and location of the baffle attached to them are different. With the separator with a baffle attached at the upper part, PET recoveries for the crushing time of 30, 60 and 90sec were 67, 98 and 99% respectably at the air flow rate of 3.5m/s, whereas PS recoveries were null regardless of the crushing time.

  • PDF

Buffer-Optimized High Gradient Magnetic Separation: Target Cell Capture Efficiency is Predicted by Linear Bead-Capture Theory

  • Waseem, Shahid;Udomsangpetch, Rachanee;Bhakdi, Sebastian C.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.125-132
    • /
    • 2016
  • High gradient magnetic separation (HGMS) is the most commonly used magnetic cell separation technique in biomedical science. However, parameters determining target cell capture efficiencies in HGMS are still not well understood. This limitation leads to loss of information and resources. The present study develops a bead-capture theory to predict capture efficiencies in HGMS. The theory is tested with CD3- and CD14-positive cells in combination with paramagnetic beads of different sizes and a generic immunomagnetic separation system. Data depict a linear relationship between normalized capture efficiency and the bead concentration. In addition, it is shown that key biological functions of target cells are not affected for all bead sizes and concentrations used. In summary, linear bead-capture theory predicts capture efficiency ($E_t$) in a highly significant manner.

Nanofiltration of Dye Solutions Through Polyamide Composite Membranes

  • Jonggeon Jegal;Baek, Kyung-Sook;Lee, Kew-Ho
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.12-19
    • /
    • 2002
  • Nanofiltration of aqueous dye solutions was carried out using polyamide (PA) nanofiltration (NF) composite membranes. The PA composite membranes were prepared by the interfacial polymerization of piperazine (PIP) and trimesoyl chloride (TMC) on the surface of microporous polysulfone (PSf) ultrafi1tration (UF) membranes. After characterization in terms of their permeation performance and surface ionic property, they were used for the separation of dye solutions such as Direct Red 75, 80, 81, and Direct Yellow 8 and 27. The separation conditions were varied to study the factors affecting on the permeation performance of the membranes: different concentrations of dye solutions, operating temperature and time, and flow rate of a feed solution. The surface property of the membrane, especially its ionic property, as a function of operating time was examined with a zeta-potentiometer and the relationship between the surface chemistry of the membrane and its permeation properties was also studied.

Water Treatment Characteristics by Foam Separator According to Operation Parameters (포말분리공정의 운전인자 변화에 따른 수처리 특성)

  • 허현철;김성구
    • Journal of Life Science
    • /
    • v.8 no.5
    • /
    • pp.504-508
    • /
    • 1998
  • A study was conducted to evaluate a protein removal characteristics by foam separation. The foam separator was operated in well-mixed tank which would be considered as a completely mixed condition. The feasibility of foam separation to remove protein from fresh and sea water was investigated. Protein removal characteristics of the foam separator were obtained by batch reactor operations. To find the effect of the operating parameter to protein removal rate, the foam separation was carried with variation of initial protein concentration and foam height. The results indicated that the protein removal efficiency was increased with increasing protein concentration and decreased with increasing foam height. The relationship between protein concentration and protein removal rate was evaluated by linear regression.

  • PDF

Multiple Camera Collaboration Strategies for Dynamic Object Association

  • Cho, Shung-Han;Nam, Yun-Young;Hong, Sang-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.6
    • /
    • pp.1169-1193
    • /
    • 2010
  • In this paper, we present and compare two different multiple camera collaboration strategies to reduce false association in finding the correspondence of objects. Collaboration matrices are defined with the required minimum separation for an effective collaboration because homographic lines for objects association are ineffective with the insufficient separation. The first strategy uses the collaboration matrices to select the best pair out of many cameras having the maximum separation to efficiently collaborate on the object association. The association information in selected cameras is propagated to unselected cameras by the global information constructed from the associated targets. While the first strategy requires the long operation time to achieve the high association rate due to the limited view by the best pair, it reduces the computational cost using homographic lines. The second strategy initiates the collaboration process of objects association for all the pairing cases of cameras regardless of the separation. In each collaboration process, only crossed targets by a transformed homographic line from the other collaborating camera generate homographic lines. While the repetitive association processes improve the association performance, the transformation processes of homographic lines increase exponentially. The proposed methods are evaluated with real video sequences and compared in terms of the computational cost and the association performance. The simulation results demonstrate that the proposed methods effectively reduce the false association rate as compared with basic pair-wise collaboration.

Adsorption Properties of Ca-exchanged Clinoptilolite under Low-temperature (Ca 이온교환 Clinoptilolite의 저온 흡착 특성)

  • Song Taek-Yong;Lee Young-Chul;Baek Young-Soon;Kim Jong-Nam
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.36-41
    • /
    • 2004
  • The breakthrough curve was obtained to evaluate separation efficiency of clinoptilolite as an methane/nitrogen separation adsorbent. The Ca-exchanged clinoptilolite showed improved separation efficiency. The nitrogen adsorption capacity of Ca-clinoptilolite was increased with decreasing temperature. The temperature was decreased from 293K to 253K(feed gas flow rate : 670ml/min, pressure : 333kPa). The adsorption capacity is increased with increasing pressure. The pressure was increased from 333kPa to 700kPa(feed gas flow rate : 670ml/min, temperature : 253K, 293K).

  • PDF

Removal of iron oxide scale from feed-water in thermal power plant using superconducting magnetic separation

  • Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.22-25
    • /
    • 2019
  • The superconducting magnetic separation system has been developing to separate the iron oxide scale from the feed water of the thermal power plant. The accumulation in the boiler lowers the heat exchange rate or in the worst case damages it. For this reason, in order to prevent scale generation, controlling pH and redox potential is employed. However, these methods are not sufficient and then the chemical cleaning is performed regularly. A superconducting magnetic separation system is investigated for removing iron oxide scale in a feed water system. Water supply conditions of the thermal power plant are as follows, flow rate 400 t / h, flow speed 0.2 m / s, pressure 2 MPa, temperature $160-200^{\circ}C$, amount of scale generation 50 - 120 t / 2 years. The main iron oxide scale is magnetite (ferromagnetic substance) and its particle size is several tens ${\mu}m$. As the first step we are considering to introduce the system to the chemical cleaning process of the thermal power plant instead of the thermal power plant itself. The current status of development will be reported.

Analysis and Evaluation of Separation Efficiency on Mass Flow of Mini Hydro Cyclone Separator Manufactured by 3D Printing (3D 프린팅을 적용한 미니 하이드로 싸이클론 분리기의 질량유량을 통한 분리효율 해석 및 평가)

  • Yi, Hyung-wook;Lee, Yeo-ul;Lee, Myung-won;Kwon, Je-young;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.89-96
    • /
    • 2021
  • In this study, a mini hydro cyclone was designed and manufactured to achieve an inlet flow rate of 2 L/min in the experiment, which was conducted using alumina powder with a specific gravity of 3.97. This hydro cyclone was studied for using in steam and water analysis system (SWAS) of thermal power plant and was manufactured by 3D printing. Numerical analysis was performed with Solidworks Flow Simulation, utilizing the reynolds stress method (RSM) of fluid multiphase flow analysis models. Experimental and numerical analysis were performed under the three conditions of inlet velocity 2.0, 4.0, and 6.0 m/s. The separation efficiency was over 80% at all inlet velocity conditions. At the inlet velocity 4m/s, the separation efficiency was the best, and it was confirmed that the efficiency was more than 90%.

Extraction of Short Peptide Using Supported Liquid Membranes (Supported Liquid Membrane을 이용한 Short Peptide의 추출)

  • Lee, Jae-Heung;Park, Ki-Moon
    • Food Science of Animal Resources
    • /
    • v.25 no.3
    • /
    • pp.340-343
    • /
    • 2005
  • The objective of this work was to study separation of short peptide (glycine-tyrosine) by using supported liquid membranes (SLMs) containing Aliquat as a cationic carrier, In the present investigation, the influence of pH of donor phase, concentrations of carrier and salt concentrations of acceptor phase on separation flux rate were investigated. Below pH 7.0 the flux rate was not affected by NaCl concentration or carrier concentration. However, the rate was increased significantly above pH 7.0. The rate with Hossain's SLM(H-SLM) containing $20\%$ Aliquat was about 3-fold higher with pH 9.0 at 0.25 M NaCl and 10-fold higher with pH 8.0 at 1.0 M NaCl than that with Duggan's SLM(D-SLM) containing $8\%$ Aliquat respectively. Furthermore, the rate with H-SLM was 10-fold higher at 1.0 M NaCl than the rate with 0.25 M NaCl, In conclusion, it would appear that the rate of separation was facilitated by using high salt concentrations together with high carrier concentrations above pH 7.0.