A Numerical Study on the Flow Characteristics of Kitchen Hood System (주방용 후드시스템의 유동특성에 관한 수치적 연구)

  • Lim Kyung-Bin;Lee Kwang-Sub;Lee Chang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.359-369
    • /
    • 2006
  • This study aims deriving analysis the flow characteristic of kitchen hood system with using 3-D numerical analysis method and improving the system to expel pollutes more efficiently. This system is applied with $k-{\varepsilon}$ turbulent model and using incompressibility viscosity flow range and boundary condition which are related to Bossinesq approximation following density variation in control volume. To understand the flow characteristics of four models, this study only focuses on velocity field, temperature field, and concentration field varying with followings whether separation plate is set or not and the shapes of separation plates. The quantity of air, speed of exhaust fan and temperature and concentration of heating source are concerned as constant values.

Water Treatment Characteristics by Foam Separator According to Operation Parameters (포말분리공정의 운전인자 변화에 따른 수처리 특성)

  • 허현철;김성구
    • Journal of Life Science
    • /
    • v.8 no.5
    • /
    • pp.504-508
    • /
    • 1998
  • A study was conducted to evaluate a protein removal characteristics by foam separation. The foam separator was operated in well-mixed tank which would be considered as a completely mixed condition. The feasibility of foam separation to remove protein from fresh and sea water was investigated. Protein removal characteristics of the foam separator were obtained by batch reactor operations. To find the effect of the operating parameter to protein removal rate, the foam separation was carried with variation of initial protein concentration and foam height. The results indicated that the protein removal efficiency was increased with increasing protein concentration and decreased with increasing foam height. The relationship between protein concentration and protein removal rate was evaluated by linear regression.

  • PDF

Preparation of PVDF/PDMS Composite Membrane and Separation of n-butanol/water Mixtures by Pervaporation (PVDF/PDMS 복합막의 제조와 투과증발을 이용한 n-부탄올/물 혼합물의 분리)

  • Lee, Yong-Taek;Jee, Ki-Yong;Jeon, Eun-Joo;Kim, No-Won
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.212-221
    • /
    • 2009
  • This study focuses on preparation of PVDF/PDMS composite membranes to effectively separate butanol from water-butanol mixture using pervaporation. We prepared various composite membranes by changing PVDF concentration of support layer and PDMS cross-linking condition of active layer. Pervaporation performance was tested by measuring butanol flux and separation factor with various cases of butanol concentration, temperature, and flow rate of feed. As results, performance of our novel PVDF/PDMS membranes surpasses that of PVDF/POMS membrane, manufactured by GKSS (Germany), in term of butanol flux, permeate concentration, and separation factor.

Development of Rotating Cone Type Garlic Clove Separator (III) - Design and Performance Evaluation of Final Protype - (회전 원추형 마늘 쪽분리기 개발에 관한 연구 (III) - 최종기 설계 및 성능평가 -)

  • Lee, J.S.;Kim, K.B.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.84-90
    • /
    • 2007
  • This study was conducted to design and manufacture a final prototype of garlic separator and to evaluate its performance. The performance of garlic separation was compared with manual separation. The final prototype for garlic separation consists of bucked-elevator device for automatic feed of garlic, rotating cone typed device, blower, and power transmission device. The optimal condition of outlet clearance was 19 mm and in this clearance, the proportions of fragment garlic separated in the large quality of Namdo garlic and all quality of Uiseong garlic were above 95% and above 85%, respectively. All proportion of damaged garlic was below 5% for all variety and quality. The garlic separation capacities of this developed machine were 310 kg/h for Namdo garlic and 293.6 kg/h for Uiseong garlic in the large quality. Capacities of final prototype compared with human being were $12.9{\sim}19.6$ times for Namdo and $24.2{\sim}31.7$ times Uiseong garlic, respectively.

The Preparation of a Polyimide Membrane for the Separation of Water-Acetic Acid Mixture through Pervaporation (Polyimide 막에 의한 물-초산계의 투과증발 분리)

  • 박영태
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.215-220
    • /
    • 1999
  • The asymmetric polyimide [PI] membrane with good solvent-resisting and heat-resisting properties was prepared by using the phase inversion method from polyamic acid, and its pervaporation separation characteristics of water-acetic acid system were studied. It was appeared from the prepared membranes that the best non-solvent of polyamie acid for the phase inversion was toluene. The best heat-treatment condition for the imidization of polyamic acid was 1 hr heating at each of the temperatures, 373, 473, and 573 K The thermal durability and chemical stability during the pervaporation separation of water-acetic acid of the prepared PI membrane was superior. The pervaporation characteristics of prepared membrane were 180 of separation factor and 0.5 kg/$m^2$hr of total flux for 80 wt% acetic acid feed.

  • PDF

Separation of Proteins Mixture in Hollow Fiber Flow Field-Flow Fractionation

  • Shin, Se-Jong;Nam, Hyun-Hee;Min, Byoung-Ryul;Park, Jin-Won;An, Ik-Sung;Lee, Kang-Taek
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1339-1344
    • /
    • 2003
  • Flow field-flow fractionation (FlFFF) is a technology to separate the molecules by size in an open channel. Molecules with different size have different diffusivities and are located vertically in different positions when passing through an open channel. In this study, hollow fiber membranes instead of conventional rectangular channels have been used as materials for the open channel and this change would decrease the cost of manufacturing. FlFFF is a useful technique to characterize the biopolymeric materials. Retention time, diffusion coefficients and Stokes radius of analysis can be calculated from the related simple equations. Hollow-fiber flow field-flow fractionation (HF-FlFFF) has been used for the characterization and separation of protein mixture in a phosphate buffer solution and has demonstrated the potential to be developed into a disposable FlFFF channel. The important indexes for the analytical separation are selectivity, resolution and plate height. The optimized separation condition for protein mixture of Ovalbumin, Alcohol dehydrogenase, Apoferritin and Thyroglobulin is ${\dot V}_{out}/{\dot V}_{rad}=0.65/0.85\;mL/min$.

DNA Separation Using Cellulose Derivatives and PEO by PDMS Microchip

  • Kang, Chung-mu;Back, Seung-Kwon;Song, In-gul;Choi, Byung-ok;Chang, Jun-keun;Cho, Keun-chang;Kim, Yong-seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.519-523
    • /
    • 2006
  • Poly(dimethyl siloxane) (PDMS) has been employed as a microchip material for DNA separation in microfluidic condition. Different sieving molecules such as cellulose derivatives having glucose building block (methyl cellulose (MC), hydroxyethyl cellulose (HEC), and hydroxypropyl methyl cellulose (HPMC)) and polyethylene oxide (PEO) having linear (ring-opened ethylene oxide) unit were used and their performance was compared in terms of separation efficiency and resolution. In general, PEO showed better separation performance than cellulose derivatives probably due to the nature of linear shape polymer conformation. It was possible to perform at least 15 consecutive running with 1.2% PEO at the electric field strength around 200 V/cm. Fast analysis of the standard $\Phi$X 174 RF DNA/Hae III (less than 130s) was obtained with the number of the theoretical plate around 250,000/m. Our PMDS microchip was applied to the measurement of CAG repeat number, which is related to male infertile disease.

Chiral Separation of Arylalcohols by Capillary Electrophoresis Using Sulfonated β-Cyclodextrin and Ag Colloids as Additives

  • Choi, Seong-Ho;Noh, Hyen-Ju;Lee, Kwang-Pill
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1549-1554
    • /
    • 2005
  • Chiral separation of arylalcohols such as 1-phenyl-1-propanol, 1-phenyl-2-propanol, and 2-phenyl-1-propanol by capillary electrophoresis was studied using sulfonated $\beta$-cyclodextrin (CD) as a chiral selector and Ag colloids as an additive. The optimum separation condition of arylalcohols was found to be the chiral selector concentration of 6.5 mM, applied voltage of 15 kV, and pH of 7.0. In order to improve chiral separation, an Ag colloid was mixed with a running buffer. The resolution in the Ag colloid-mixed running buffer was considerably superior to that obtained with the sulfonated $\beta$-CD alone. The molar ratio of sulfonated $\beta$-CD to Ag colloid, which is one of critical parameters affecting resolution, was found to be optimum at 65 : 1. In order to elucidate the resolution mechanism, an inclusion-complex of the arylalcohols with sulfonated $\beta$-CD was prepared by mixing and shaking in solution, and then characterized by cyclic voltammetry (CV). The inclusion mechanism was also discussed using experimental results.

Separation of VOCs from Air through Composite Membranes Prepared by Plasma Polymerization of Hexamethyldisiioxane (Hexamethyldisiioxane의 플라즈마 중합에 의하여 제조된 복합막을 통한 공기중의 휘발성 유기물질의 분리에 관한 연구)

  • 류동현;오세중;손우익;구자경
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.63-65
    • /
    • 1998
  • 1. Introduction : Atmospheric discharge of VOC-contaminated streams in chemical plants and air streams from chemical processes poses a serious environmental problem and entails large financial losses. Such emissions may be reduced by i) adsorption process, ii) absorption process and iii) incineration process. These processes only forbids the air pollutions. Throughout the recent decade, another technique-membrane process has emerged. The separation and recovery of organic vapors by membrane process may have great economic potential. Most of the published research works on the separation of organic vapors from air were performed using silicon rubber membranes. However, it is very difficult to fabricate very thin membranes with less than 1 $u m thickness. Plasma polymerization could be a good technique to generate a thin polymer film. The objective of this work is to find out the optimum condition of plasma polymerization for producing VOC separation membrane. For the objective, composite membranes are prepared through plasma polymerization of hexamethyldisiloxane onto porous substrates under different conditions. The membrane is then subjected to the permeation of permanent gases and VOCs to find the correlations between the physical properties of the penetrant and permeability and selectivity.

  • PDF

A Study on the Use of TRIZ for Generating High Value Patents: Focusing on the US Granted Patents of Samsung Electronics Company (가치가 높은 특허 창출을 위한 TRIZ 활용방안 연구: 삼성전자 미국등록 특허를 중심으로)

  • Song, MyungWon;Park, Young Taek
    • Journal of Engineering Education Research
    • /
    • v.21 no.6
    • /
    • pp.81-89
    • /
    • 2018
  • Patents have been recognized as a core knowledge asset which are closely related with company's technological competitiveness. However, only a small portion of patents are actually contributing to the profit of the company. In addition, it costs a lot of money continuously to maintain the patent rights regardless of their values. Thus, effective methodologies are required to create patents with high values. It is examined what kind of differences exist between high value patents and the others in the use of TRIZ methodologies. For the purpose, we analyzed the US granted patents of Samsung Electronics. The analysis shows that there is no significant difference in the use of inventive principles, but high value patents utilize 'separation by condition' the most where as the others 'separation by space' the most frequently in the use of separation principles. In the use of standard solutions, high value patents use the 'class 2' principles frequently than the others.