• Title/Summary/Keyword: Separated Device

Search Result 227, Processing Time 0.032 seconds

Children with Disabilities on the Basis of Characteristics and Ease Usability Testing of the Stroller (장애아동 특성과 편리성을 바탕으로 디자인된 유모차의 사용성 평가)

  • Oh, D.Y.;An, N.Y.;Kong, J.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.267-273
    • /
    • 2014
  • The purpose of this study is to figure out the stroller for baby with physical disability and to suggest improvement by using the usability test. Usability evaluation is separated by the user and the expert evaluation was conducted. Strollers for disabled users to analyze the evaluation of this experience using a guardian of a child with a disability was conducted targeting 30 people. The function and structure of the stroller easy to evaluate whether the five-point scale. Professional 10 strollers for disabled users with the problems of the design and structure were looking to make a suggestion. In this study, to obtain foreign products and differentiation, functionality, and ease of analyzing the conditions of satisfaction and competitiveness of domestic products will be able to contribute.

  • PDF

Fabrication of Graphene p-n Junction Field Effect Transistors on Patterned Self-Assembled Monolayers/Substrate

  • Cho, Jumi;Jung, Daesung;Kim, Yooseok;Song, Wooseok;Adhikari, Prashanta Dhoj;An, Ki-Seok;Park, Chong-Yun
    • Applied Science and Convergence Technology
    • /
    • v.24 no.3
    • /
    • pp.53-59
    • /
    • 2015
  • The field-effect transistors (FETs) with a graphene-based p-n junction channel were fabricated using the patterned self-assembled monolayers (SAMs). The self-assembled 3-aminopropyltriethoxysilane (APTES) monolayer deposited on $SiO_2$/Si substrate was patterned by hydrogen plasma using selective coating poly-methylmethacrylate (PMMA) as mask. The APTES-SAMS on the $SiO_2$ surface were patterned using selective coating of PMMA. The APTES-SAMs of the region uncovered with PMMA was removed by hydrogen plasma. The graphene synthesized by thermal chemical vapor deposition was transferred onto the patterned APTES-SAM/$SiO_2$ substrate. Both p-type and n-type graphene on the patterned SAM/$SiO_2$ substrate were fabricated. The graphene-based p-n junction was studied using Raman spectroscopy and X-ray photoelectron spectroscopy. To implement low voltage operation device, via ionic liquid ($BmimPF_6$) gate dielectric material, graphene-based p-n junction field effect transistors was fabricated, showing two significant separated Dirac points as a signature for formation of a p-n junction in the graphene channel.

An Experimental Study on Performance of a Miniaturized Exploding Foil Initiator using VISAR (VISAR를 활용한 초소형 EFI 기폭 장치의 성능 특성 연구)

  • Yu, Hyeonju;Jang, Seung-gyo;Kim, Kyu-Hyoung;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.80-87
    • /
    • 2017
  • The performance of a pyrotechnic device that consists of donor/acceptor pair separated by a bulkhead relies on shock attenuation characteristics of the gap material and shock sensitivity of the donor and acceptor explosives. In this research, a micro Kapton flyer was accelerated by an exploding foil initiator (EFI) to figure out shock sensitivity of hexanitrostilbene (HNS) to impact. The averaged shock pressure and duration imparted to the explosive by flyer impact are measured by using a velocity interferometer for any reflector (VISAR) and impedance matching technique. Consequently, this research shows the possibility to determine the critical flyer velocity for initiating the miniaturized pyrotechnic unit by determining the relations between the impact velocity, the amplitude and width of impact loading.

A performance study of organic solar cells by electrode and interfacial modification (전극과 계면간의 개질에 의한 유기태양전지의 성능 연구)

  • Kang, Nam-Su;Eo, Yong-Seok;Ju, Byeong-Kwon;Yu, Jae-Woong;Chin, Byung-Doo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.67-67
    • /
    • 2008
  • Application of organic materials with low cost, easy fabrication and advantages of flexible device are increasing attention by research work. Recently, one of them, organic solar cells were rapidly increased efficiency with regioregular poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl-C61-butyricacidmethylester (PCBM) used typical material. To increased efficiency of organic solar cell has tried control of domain of PCBM and crystallite of P3HT by thermal annealing and solvent vapor annealing. [4-6] In those annealing effects, be made inefficiently efficiency, which is increased fill factor (FF), and current density by phase-separated morphology with blended P3HT and PCBM. In addition, increased conductivity by modified hole transfer layer (HTL) such as Poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS), increased both optical and conducting effect by titanium oxide (TiOx), and changed cathode material for control work function were increased efficiency of Organic solar cell. In this study, we had described effect of organic photovoltaics by conductivity of interlayer such as PEDOT:PSS and TCO (Transparent conducting oxide) such as ITO, which is used P3HT and PCBM. And, we have measured with exactly defined shadow mask to study effect of solar cell efficiency according to conductivity of hole transfer layer.

  • PDF

A HISTOMORPHOMETRIC STUDY OF BONE FORMATION AROUND IMPLANTS PLACED AFTER VERTICAL ALVEOLAR DISTRACTION IN THE DOG MEDEL (치조골신장 부위에 식립된 임프란트 주위의 골형성에 관한 연구)

  • Park, Jong-Oh;Rhu, Dong-Mok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.312-321
    • /
    • 2007
  • Purpose: Distraction osteogenesis has been applied to the maxillofacial implantology and good experimental and clinical results have been reported. However, histologic studies of implants placement on distraction osteogenesis of atrophic alveolar ridges are scarce. In this study, we compare the bone formation between in the transport part and in the distraction part by histomorphometric analysis. Materials & methods: Three adult beagle dogs were served as experimental subjects. The 2 premolars and 1st molar were extracted on the Lt. side of mandible in each beagle dog. After one month later, osteotomy was performed and distraction device was adapted. Distraction was performed with gradual incremental separation of two bone pieces at a rate of 1.0mm per day for 5 days. During consolidation phase, new bone was formed in the distraction zone between the separated bone pieces. 5 weeks after distraction phase, 3 implants were placed in each beagle dog. The implants were inserted through transport part and distraction part and inferior basal bone. The animals were sacrificed at 2 weeks, 4 weeks, and 12 weeks after implant placement. BIC and BA of implants on distraction part and transport part were measured histomorphometrically. Results: BIC, BA increased after implant placement as time goes by passes and new bone formation was slightly higher in transport part than in distraction part at 2 weeks, 4 weeks after implant placement. At 12 weeks after implant placement, BIC, BA of were 74%, 61% in transport part and 77%, 59% in distraction part, therefore there were no difference in BIC and BA between transport part and distraction part at 12 weeks after implant placement.

The Extraction of Table Lines and Data in Document Image (문서영상에서 표 구성 직선과 데이터 추출)

  • Jang, Dae-Geun;Kim, Eui-Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.556-563
    • /
    • 2006
  • We should extract lines and data which consist of the table in order to classify the table region and analyze its structure in document image. But it is difficult to extract lines and data exactly because the lines are cut and their lengths are changed, or characters or noises are merged to the table lines. These problems result from the error of image input device or image reduction. In this paper, we propose the better method of extracting lines and data for table region classification and structure analysis than the previous ones including commercial softwares. The prposed method extracts horizontal and vertical lines which consist of the table by the use of one dimensional median filter. This filter not only eliminates the noises which attach to the line and the lines which are orthogonal to the filtering direction, but also connects the cut line of which the gap is shorter than the length of the filter tap in the process of extracting lines to the filtering direction. Furthermore, texts attached to the line are separated in the process of extracting vertical lines. This is an example of ABSTRACT format.

High-Speed RNA Isolation Using Magnetic Oligo(dT) Beads and Lateral Magnetophoresis (올리고-dT 자성입자와 측면방향 자기영동을 이용한 초고속 RNA 추출 기술)

  • Lee, Hwan-Yong;Han, Song-I;Han, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1309-1316
    • /
    • 2011
  • This paper presents a high-speed RNA microextractor for the direct isolation of RNA from blood lysate using magnetic oligo(dT) beads. The extraction is performed through lateral magnetophoresis, which is induced by a ferromagnetic wire array inlaid. With this RNA microextractor, more than 80% of the magnetic beads could be separated at a flow rate up to 20 ml/h, and the overall extraction procedure was completed within 1 min. The absorbance ratio of RNA to protein(A260/A280) was greater than 1.7, indicating that the extraction technique yields pure RNA. The feasibility of using this technique in reverse transcription polymerase chain reaction procedures was investigated by cDNA synthesis and PCR processes. The results confirmed that the RNA microextractor is a practical device for easy, fast, and high-precision RT-PCR using minimal amounts of reagent.

Development of On-Line Measurement System for Adsorption Process (흡착공정용 온라인 측정시스템의 개발)

  • Kim, Byoung Chul;Lee, Ki Sung;Yamamoto, Takuji;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.321-326
    • /
    • 2009
  • A simple measuring device is proposed, and its performance is examined in an adsorption process separating a gas mixture. The sensor is made of a quartz crystal resonator and solid adsorbent to detect the target component. Micro-particle carbon cryogel(MCC) is utilized as the adsorbent, and the gas mixture of air and i-butane are separated in a column containing bamboo activated carbon. Two devices are placed at the inlet and outlet of the column. The measurements are compared with those of GC outcome to prove the measurements are effective. The experimentally proved system is simple and capable to be implemented in an in-line system with on-line measurement.

A study on User Experience of Automatic Ticket Vending Machine UI :Focused on Seoul Metro Line 9 (지하철 무인 승차권 발매기 UI 사용 경험 연구 :서울시 지하철 9호선 1회용 발매기 중심으로)

  • Hwang, Shin-Hye;Choe, Jong-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.54-61
    • /
    • 2015
  • The ATVM(Automatic Ticket Vending Machine) of Seoul Metropolitan is a Kiosk which is called Ticket Vending and Reload Device at the subway station. It is implemented for integrating transportation card system which is separated from a paper subway ticket and replacing ticket selling employees. However, since the automatic ticket vending machine was accepted in 2009, there has been confusion of purchasing a ticket. Therefore, it requires improvement of usability. This study, conducts a literature search. Also, the interface of ATVM is analyzed. Finally user observation proceeded at Sinnonhyeon Station of Seoul Metro line 9. The results show that selecting a destination and section fares is confusing process for user. Based on this survey the improvements of UI are proposed to expect advanced directions of the ATVM.

Computerizing Clinical Laboratory with Clinical Devices Interface : I. With a focus on ABGA(Arterial Blood Gas Analyzer) (임상 의료장비 인터페이스를 이용한 검사실 전산화 구현 : I. ABGA(Arterial Blood Gas Analyser)를 중심으로)

  • Kim, Sun-Chil;Kwon, Deok-Moon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.21-26
    • /
    • 2006
  • Hospitals these days are trying to introduce the a practice has recently been generalized in the test or diagnosis process, where test results and images from different test labs are interlinked together. This process is identical to that of physical aspect in EMR process, which computerizes the paper results within the hospital. One of the prerequisites for the process of computerizing test results is the interface between clinical test devices in the test labs. However, due to the variety of prescription inputs, disparity of test result papers, complexity of job in test labs and diversify of interfaces among the different devices, interconnection with the hospital information system is a complicated job. A universal control of clinical test devices which have independent communication protocols has become possible by connecting them with an interface workstation. As for the patients, waiting time for test has been reduced, and, thanks to the synchronized result retrieval system, it has become possible to check the test results on the very day of the test. As a result, the length of hospitalization has been reduced, too. In terms of workflow, as the transfer of charts and transfer of result papers are separated, the embarrassing job of collecting result papers has disappeared. As patients' test appointment and the results processing can be made on-line, extra work for doctors have disappeared. And, thanks to the computerization of test results information management, the job of statistical processing has become convenient.

  • PDF