• Title/Summary/Keyword: Sensor type

Search Result 2,719, Processing Time 0.032 seconds

A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor (부착형 고분자 압전센서를 이용한 탄성파 검출 연구)

  • Kim, Ki-Bok;Yoon, Dong-Jin;Kueon, Jae-Hwa;Lee, Young-Seop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.268-274
    • /
    • 2004
  • Patch type piezo-polymer sensors for smart structures were experimented to detect elastic wave. The pencil lead braking test was performed to analyze the characteristics of patch-type piezo-polymer sensors such as polyvinyliden fluoride (PVDF) and polyvinylidene fluoride trifluorethylene (P(VDF-TrFE)) for several test specimens with various elastic wave velocities and acoustical impedances. The characteristics of the patch-type piezo-polymer sensor were compared with the commercial PZT acoustic emission (AE) sensor. The vacuum grease and epoxy resin were used as a couplant for the acoustic impedance matching between the sensor and specimen. The peak amplitude of elastic wave increased as the diameter of piezo-film and acoustical impedance of the specimen increased. The frequency detection range of the piezo-film sensors decreased with increasing diameter of the piezo-film sensor. The P(VDF-TrFE) sensor was more sensitive than the PVDF sensor.

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.

Development of a Fine Digital Sun Sensor for STSAT-2

  • Rhee, Sung-Ho;Lyou, Joon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2012
  • Satellite devices for fine attitude control of the Science & Technology Satellite-2 (STSAT-2). Based on the mission requirements of STSAT-2, the conventional analog-type sun sensors were found to be inadequate, motivating the development of a compact, fast and fine digital sun sensor (FDSS). The FDSS uses a CMOS image sensor and has an accuracy of less than 0.03degrees, an update rate of 5Hz and a weight of less than 800g. A pinhole-type aperture is substituted for the optical lens to minimize its weight. The target process speed is obtained by utilizing the Field Programmable Gate Array (FPGA), which acquires images from the CMOS sensor, and stores and processes the image data. The sensor accuracy is maintained by a rigorous centroid algorithm. This paper describes the FDSS designs, realizations, tests and calibration results.

Characteristics of CMOS ISFET pH sensor as packaging type (Packaging 형태에 따른 CMOS ISFET pH 센서의 특성평가)

  • Shin, Kyu-Sik;Roh, Ji-Hyoung;Cho, Nam-Kyu;Lee, Dae-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.517-518
    • /
    • 2008
  • Highly integrated ISFETs require the monolithic implementation of ISFETs, CMOS electronics, and additional sensors on the same chip This paper presents novel packaging type of CMOS ISFET pH sensor using standard CMOS FET chip and extended sensing membrane which is separated from CMOS FET. This proposed packaging type will make it easy to fabricate CMOS ISFET pH sensors

  • PDF

Diaphragm-Type Pressure Sensor with Cu-Ni Thin Film Strain Gauges-II : Design Fabrication and Characteristics of a Pressure Sensor (Cu-Ni 박막 스트레인 게이지를 이용한 다이어프램식 압력 센서-II:압력 센서의 설계 제작의 특성)

  • 민남기;전재형;박찬원
    • Electrical & Electronic Materials
    • /
    • v.10 no.10
    • /
    • pp.1022-1028
    • /
    • 1997
  • In this paper we present the construction details and output characteristics of a diaphragm-type pressure sensor with Cu-Ni(53:47) thin-film strain gauges. In order to improve the sensitivity and the temperature compensation two circumferential gauges are placed near the center of the diaphragm and two radial gauges are located near the edge. For all the gauges the relative change in resistance ΔR/R with pressure is of the order 10$^{-3}$ for the maximum pressure. The output is found to be linear over the entire pressure range(0-30kfg/cm$^2$)and the output sensitivity obtained is 1.6mV/V. The maximum nonlinearity observed in output characteristics is 0.35%FS for 5V excitation and the hysteresis is less than 0.1%FS.

  • PDF

The measurement of capacitance of W/O type emulsified fuel using by capacitance sensor (정전용량센서를 이용한 W/O형 유화연료의 정전용량 측정)

  • Cho, Seong-Cheol;Oh, Yang-Hwan;Im, Seok-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.377-382
    • /
    • 2007
  • We designed capacitance sensor in order to examine characteristics of W/O type emulsified fuel, so it concluded the following conclusions. The capacitance value of emulsified fuel, using with capacitance sensor, increases as water content increases due to the coalescence. When surfactant increases, the capacitance value decreases, the condition of W/O type emulsified fuel was maintained stably. There was revealed the capacitance value difference of W/O type emulsified fuel in in according to water content. We checked the phase separation of emulsified fuel with the capacitance value difference. The surfactant(HLB=5.4) had better stable condition than surfactant(HLB=4.3). Also, we confirmed that two mixture surfactants were better than one surfactant.

Bi-electrolyte Carbon Dioxide Gas Sensor Based on Paste Sodium-Beta Alumina and Yttria-stabilized Zirconia

  • Han, Hyeuk Jin;Park, Chong Ook
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.170-172
    • /
    • 2014
  • $CO_2$ sensor was used only one solid electrolyte in many cases. To improve the sensing characteristics of $CO_2$ sensors, solid electrolyte $CO_2$ sensor has been developed by bi-electrolyte type sensor using Na-Beta-alumina and YSZ. However, in many further studies, bi-electrolyte type sensor was made by pellet pressed by press machine and additional treatment for formation of interface. In the aspect of mass production, using thick film and additional treatment is not suitable. In this study, $CO_2$ sensor was fabricated by bi-electrolyte structure which was made by an NBA paste layer deposited on YSZ pellet and fired at $1650^{\circ}C$ for 2 hour. The formation of stable interface between YSZ and NBA were confirmed by SEM image. When the type IV electrochemical cell arrangement represented by $CO_2,O_2,Pt{\mid}Li_2CO_3-CaCO_3{\parallel}NBA{\parallel}YSZ{\mid}O_2,Pt$ is used to measure the $CO_2$ concentration in air. This sensor EMF should depend only on the concentration of $CO_2$ by logarithmic. Also, sensor shows $P_{CO_2}$ and EMF relationship like nerstian reaction at a temperature of $450^{\circ}C$.

Development of Ultrasonic Active Fiber Sensor for Structural Health Monitoring (구조물 안전진단을 위한 초음파능동형광섬유 센서의 개발)

  • Lim, Seung-Hyun;Lee, Jung-Ryul;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.747-752
    • /
    • 2008
  • Fiber-guided sensor system using a generator and a receiver can detect the amplitude of load or pressure. However, this type of sensor can show some difficulties in detecting the location of damages and pressure loadings. To overcome this weakness of this type, the ultrasonic active fiber sensor, which has an integrated ultrasonic generator and sensing part, was developed in this study. By using this sensor system, the location of mechanical loads can be exactly detected. Moreover, the ultrasonic active fiber sensor is more cost-effective than an ultrasonic fiber sensor using two piezoelectric transducers which are used as a generator and a receiver, respectively. Two applications of the ultrasonic active fiber sensor are demonstrated: cure monitoring of lead and measurement of liquid level. Present results showed that the active fiber sensor can be applied for various environmental sensing.

  • PDF

Semiconductor-Type MEMS Gas Sensor for Real-Time Environmental Monitoring Applications

  • Moon, Seung Eon;Choi, Nak-Jin;Lee, Hyung-Kun;Lee, Jaewoo;Yang, Woo Seok
    • ETRI Journal
    • /
    • v.35 no.4
    • /
    • pp.617-624
    • /
    • 2013
  • Low power consuming and highly responsive semiconductor-type microelectromechanical systems (MEMS) gas sensors are fabricated for real-time environmental monitoring applications. This subsystem is developed using a gas sensor module, a Bluetooth module, and a personal digital assistant (PDA) phone. The gas sensor module consists of a $NO_2$ or CO gas sensor and signal processing chips. The MEMS gas sensor is composed of a microheater, a sensing electrode, and sensing material. Metal oxide nanopowder is drop-coated onto a substrate using a microheater and integrated into the gas sensor module. The change in resistance of the metal oxide nanopowder from exposure to oxidizing or deoxidizing gases is utilized as the principle mechanism of this gas sensor operation. The variation detected in the gas sensor module is transferred to the PDA phone by way of the Bluetooth module.

A Cantilever Type Contact Force Sensor Array for Blood Pressure Measurement (혈압 측정을 위한 외팔보형 접촉힘 센서 어레이)

  • Lee, Byeung-Leul;Jung, Jin-Woo;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-126
    • /
    • 2012
  • Piezoresistive type contact force sensor array is fabricated by (111) Silicon bulk micromachining for continuous blood pressure monitoring. Length and width of the unit sensor structure is $200{\mu}m$ and $190{\mu}m$, respectively. The gap between sensing elements is only $10{\mu}m$. To achieve wafer level packaging, the sensor structure is capped by PDMS soft cap using wafer molding and bonding process with $10{\mu}m$ alignment precision. The resistance change over contact force was measured to verify the feasibility of the proposed sensor scheme. The maximum measurement range and resolution is 900 mm Hg and 0.57 mm Hg, respectively.