• Title/Summary/Keyword: Sensor Array

Search Result 866, Processing Time 0.029 seconds

Analysis of Breath from Diabetic Patients Based on a One-chip-type Sensor Array

  • Yu, Joon-Boo;Jang, Byoung Kuk;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.221-224
    • /
    • 2019
  • Based on the results of studies on acetone excretion in diabetic patients, a one - chip sensors array was fabricated by combining acetone-selective sensor materials and volatile-organic-compound sensitive sensor materials. An electonic-nose was implemented using a sensor array and confirmed selectivity for five gases. In this system, the excretion of diabetic patients and controls was sampled with solid phase microextraction fiber and transferred to the sensor array. Although the control and diabetic patients were distinct, several samples failed. In the control group, the results of blood tests were normal, but patients were highly obese. In addition, the gas chromatography mass spectrometry results for the subjects revealed chemicals that are external factors.

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Optimal design of a sparse planar array sensor for underwater vehicles (수중 운동체용 희소 평면배열 센서의 최적 설계)

  • Afzal, Muhammad Shakeel;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2018
  • In this study, a new design method is developed to optimize the structure of an underwater sparse array sensor. The purpose of this research is to design the structure of a sparse array that has the performance equivalent to a fully sampled array. The directional factor of a sparse planar array is derived as a function of the structural parameters of the array. With the derived equation, the structure of the sparse array sensor is designed to have the performance equivalent to that of the fully array sensor through structural optimization of the number and location of transmitting and receiving elements in the array. The designed sparse array sensor shows beam patterns very close to those of the fully array sensor in terms of PSLL (Peak Side Lobe Level) and MLBW (Main Lobe Beam Width), which confirms the effectiveness of the present optimal design method. Further, the validity of the analytic beam patterns is verified by comparing them with those from the FEA (Finite Element Analysis) of the optimized sparse array structure.

Design and fabrication of wafer scale microlens array for image sensor using UV-imprinting (UV 임프린팅을 이용한 이미지 센서용 웨이퍼 스케일 마이크로렌즈 어레이 설계 및 제작)

  • Kim, Ho-Kwan;Kim, Seok-Min;Lim, Ji-Seok;Kang, Shin-Ill
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.100-103
    • /
    • 2007
  • A microlens array has been required to improve light conversion efficiency in image sensors. A microlens array can be usually fabricated by photoresist reflow, hot-embossing, micro injection molding, and UV-imprinting. Among these processes, a UV-imprinting, which is operated at room temperature with relatively low applied pressure, can be a desirable process to integrate microlens array on image sensors, because this process provides the components with low thermal expansion, enhanced stability, and low birefringence, furthermore, it is more suitable for mass production of high quality microlens array. In this study, to analyze the optical properties of the wafer scale microlens array integrated image sensor, another wafer scale simulated image sensor chip array was designed and fabricated. An aspherical square microlens was designed and integrated on a simulated image sensor chip array using a UV-imprinting process. Finally, the optical performances were measured and analyzed.

  • PDF

Sound Measurements of the Discharge Break Down Using Fabry-Perot Sensor Array (Fabry-Perot형 광섬유 배열센서의 방전 음압 계측)

  • Lee, Jong-Kil;Lee, June-Ho;Lee, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.770-773
    • /
    • 2003
  • To measure discharge breakdown acoustic signal, Fabry-Perot interferometer fiber optic sensor is used. Fiber optic sensor array can measure the partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Fabry-Perot interferometer is selected as an fiber optic sensor array. It is shown that Fabry-Perot fiber optic sensor array detected discharge breakdown acoustic signal, effectively.

  • PDF

AN EFFICIENT SENEOR ARRAY FOR A LATFE-GAP MAGNETIC LEVITATION SYSTEM

  • Na, Seung-You;Shin, Dae-Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.154-157
    • /
    • 1995
  • A magnetic levitation control system is nonlinear and very unstable. Thus there should be a stabilizing compensation network and a feedback path. Due to the levitation control a noncontact photoresistor sensor is generally used. One photocell provides a certain amount of variation in length by the ball shadow casted on the cell surface. Furthermore at the boundary of the cell, the linearity of sensitivity deteriorates severely. To overcome the constraints of the length and linearity, an efficient sensor array is deviced and applied in the feedback path of a large-gap magnetic levitation control system. A number of CdS photocells and a summing circuit of the sensor output signals are used for a sensor array. The levitation length of a ball and the transient performances are main objectives of the large-gap suspension system using the sensor array.

  • PDF

A New Shack-Hartmann Type Wavefront Sensor Using Liquid Crystal Panels

  • Xiaoxi, Chen;Xu, Liu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.528-530
    • /
    • 2005
  • In this paper, we present a new and practical method for achieving real-time wavefront measurement, dramatically increasing the resolution, dynamic range of Shack-Hartmann wavefront sensor and improving the wavefront reconstruction quality. In proposal method, a liquid crystal display panel (LCD) for the generation of an array of Fresnel microlenses is use instead of the static microlens array of the conventional Shack-Hartmann type sensor. An off-axis holographic microlens array is designed instead of the normal microlens array to increase the effective array and then the dynamic range. The focus properties of the off-axis lens are studied.

  • PDF

Development of an Illumination Measurement Device for Color Distribution Based on a CIE 1931 XYZ Sensor

  • Son, Do-Ky;Cho, Eun-Byeol;Moon, In-Kyu;Park, You-Sang;Lee, Chung-Ghiu
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.44-51
    • /
    • 2011
  • In this paper, an easy-to-use measurement device for illumination distribution is developed. The device consists of a sensor array module, a control module, and a PC interface. The sensor array module incorporates CIE 1931 color sensors and the ARM-based 96 MHz microcontroller in the control module for measurement and data processing. The sensor array module contains 64 color sensors arranged in a $16{\times}4$ array. The sensitivity of the sensor array module can be adjusted depending on the illumination level to be measured. The measurement data and control signals are exchanged via USB 2.0 standard. To demonstrate the performance of the device, the illumination distribution is measured for colors of red, green, and blue and is graphically shown. The device can be used for measurement of the illumination distribution, design and adjustment of LED illumination.

Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement (비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구)

  • Kim, Eun-Geun;Nam, Ki-Chang;Heo, Hyun;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF

Low Noise Characteristics of the Comformal Sensor Array's Support Structure (곡면배열 센서의 저소음화를 위한 지지구조 설계 구조)

  • Lee, Jong-Kil;Lee, Sang-Won;Seo, Hee-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.340-341
    • /
    • 2010
  • Noise reduction is an important factor to design low noise sensor array. In this paper three layers of the de-coupler in the conformal sensor array were used to investigate noise reduction. Conformal sensor array is positioned in the layers and the distance from the layer is 0.25cm~1.5cm. Transfer function in the frequency density function is investigated according to the three different positions. When increasing the embedded distance the flow noise decreased in the region of the kx>10.

  • PDF