• Title/Summary/Keyword: Sensitivity study

Search Result 9,223, Processing Time 0.049 seconds

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

Regulation of Gb3 Expression on Dendritic Cells (수지상세포에 있어서 베로독소 수용체의 발현조절)

  • Lim, Suk-Hwan;Kim, Gi-Young;Kim, Hyung-Chun;Kim, Young-Hee;Son, Yong-Hae;Oh, Yang-Hyo;Park, Yeong-Min
    • Journal of Life Science
    • /
    • v.17 no.4 s.84
    • /
    • pp.482-492
    • /
    • 2007
  • Infection with Shiga-like toxin (SLT)-producing Escherichia coli causes a spectrum of illnesses with high morbidity and mortality. Host mediators play an important role in the pathogenesis of SLT-I toxicity. We here investigated the effect of SLT-I on tumor necrosis $factor-{\alpha}\;(TNF-{\alpha})$ production, effect of $TNF-{\alpha}$ on glycolipid globotriaosyleramide (Gb3) expression, and relationship between Gb3 level and differential susceptibility of cells to SLT-I. In this study, we observed that detectable levels of $TNF-{\alpha}$ are produced 6 hrs after induction and continued to increase during 48 hrs by SLT-I. It was also found that Vero cells and dendritic cells expressed high levels of Gb3, 83% and 68%, respectively, and that macrophages had a low level of Gb3 (29%) and showed refractory to cytotoxicity against SLT-I. Vero cells and dendritic cells expressing high levels of Gb3 were highly susceptible to SLT-I. furthermore, macrophages showed a resistance to SLT-I cytotoxicity, despite the fact that Gb3 expression was enhanced. These results suggest that the expression of Gb3 is necessary, but not sufficient to confer sensitivity of macrophages to SLT-I and further underpin the important role of SLT-I and its receptor, Gb3, in the pathogenesis of E. coli O157 infection.

Competitive ELISA for the Measurement of Glycoprotein Purified from Acanthopanx senticosus (가시오가피로부터 분리한 단백 다당물질의 경쟁적 ELISA법에 의한 분석)

  • Ha, Eun-Suk;Hwang, Soo-Hyun;Shin, Kwang-Soon;Yu, Kwang-Won;Lee, Keyung-Ho;Choi, Joo-Sun;Park, Woo-Mun;Yoon, Taek-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1209-1215
    • /
    • 2003
  • This study was carried out to establish a quantitative analysis method of separating immuno-activating substance (EN-SP) from Acanthopanax senticosus (A. senticosus) by competitive direct ELISA. Mouse antiserum (anti-EN-SP) against EN-SP was generated by immunization (s.c.) of EN-SP purified from A. senticosus as an immunogen. The titer of anti-EN-SP was about 1 : 400, and the optimal dilution of EN-SP-HRP conjugate was 1 : 1,000. When the standard curve was constructed by ELISA, its sensitivity was about $0.2{\mu}g/mL$. The coefficient variation of intra- and inter-assay were $6.13{\sim}8.81%$ and $6.73{\sim}8.60%$, respectively. According to the standard curve, the concentration of EN-SP in various senticosus extracts was found to be only $59.85\;{\mu}g$ in 10mg of extract from the bark of A. senticosus. Similarly, the immunostimulating activity to produce $TNF-{\alpha}$ or IL-12 among the various extracts of Acanthopanax was shown to be correlated with the content of EN-SP. These results demonstrated that competitive ELISA was a convenient, fast, reproducible, and accurate method for the determination of EN-SP as an immunologically active standard substance in extract of A. senticosus.

Clinical Significance of Follow-up CT after Ultrasonography for Acute Appendicitis in Children (소아 급성 충수염에서 복부초음파 이후 전산화단층촬영 추적 검사의 임상적 의의)

  • Yu, Seong-Keun;Moon, Jin-Soo;Kim, Nam-Hee;Hwang, Jong-Hee;Nam, Seung-Yeon;Kim, Dong-Wook;Lee, Chong-Guk;Seo, Jung-Wook;Heo, Tae-Gil
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: The ultrasonography (USG) and computed tomography (CT) are popular diagnostic tools for the diagnosis of acute appendicitis in children, but there are many debates about their clinical significance. The purpose of this study is to clarify the clinical significance of USG, CT and follow-up CT performed subsequently to USG, especially in perforated acute appendicitis in children. Methods: We have reviewed 419 cases of surgically confirmed acute appendicitis in children under the age of sixteen, who had been treated in Inje University Ilsan Paik Hospital from March 2002 to February 2006. All the clinical data including the results of USG and CT were collected and analyzed. Results: Sensitivity, specificity, positive and negative predictive values of USG were 98.7%, 96.8%, 98.1%, 97.8% in non-perforation group and 90.8%, 100%, 100%, 81.9% in perforation group. Those of CT were 96.4%, 100%, 100%, 96.5% and 86.6%, 100%, 100%, 87.5% respectively. Those of follow-up CT after USG were 100%, 100%, 100%, 100% and 87.5%, 100%, 100%, 92.0% respectively. The duration of using antibiotics in seven patients showed positive correlation with the interval between two imaging studies (r=0.0472, p=0.019). There was no statistical significance of correlation when these imaging studies performed within 30 hours together. Conclusion: In most of the cases, single choice between USG and CT would be enough to diagnose the acute appendicitis in children. But, it may be helpful to perform CT as early as possible subsequently to USG when there is discrepancy between initial USG and clinical impression.

  • PDF

Susceptibility of Two Potato Cultivars to Various Environmental Stresses (다양한 환경스트레스에 대한 감자 2품종의 감수성 분석)

  • Tang, Li;Kwon, Suk-Yoon;Sung, Chang-K;Kwak, Sang-Soo;Lee, Haeng-Soon
    • Journal of Plant Biotechnology
    • /
    • v.30 no.4
    • /
    • pp.405-410
    • /
    • 2003
  • Environmental stress is the major limiting factor in plant productivity. In order to evaluate the stress tolerance of potato plants, leaf discs of two potato cultivars, Atlantic and Superior, were subjected to various stress conditions of high temperature, methyl viologen, H2O2, or $H_2O$$_2$. When potato leaf discs were exposed to high temperature at 37$^{\circ}C$ for 84 hr, Atlantic plants, a cultivar with high sensitivity to heat stress, showed about 20% higher membrane damage than Superior plants. When exposed to 2$\mu$M methyl violgen (MV), a superoxide generating non-selective herbicide, for 36 hr, Atlantic plants also showed about 38% higher membrane damage than Superior plants, and were more susceptible up to 10$\mu$M MV concentration tested. On treatment with 0.75M NaCl, Atlantic plants also had about 45% less chlorophyll contents in leaf discs than Superior plants. There was, however, no difference in chlorophyll content of two cultivars at higher NaCl concentrations. The effect of $H_2O$$_2$ on the two cultivars was mixed. At low $H_2O$$_2$ concentration (25 mM) , Superior plants were more susceptible to $H_2O$$_2$stress after 36 hr. However, at high $H_2O$$_2$ concentration (100 mM), Atlantic plants exhibited higher susceptibility after 36 hr. The results indicate that in vitro leaf discs reflecting the whole plants in this study will be useful for selection and characterization of elite transgenic potato plants with enhanced tolerance to environmental stress.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF