• Title/Summary/Keyword: Sensitivity and specificity

Search Result 2,269, Processing Time 0.038 seconds

Utility of FDG-PET in Solitary Pulmonary Nodules and the Relationship Between Standardized Uptake Values of PET and Serum Glucose (폐 결절에서 FDG-PET의 유용성과 표준섭취계수와 혈당농도의 상관관계)

  • Kim, Kyu Sik;Lim, Sung Chul;Ko, Young Chun;Park, Kyung Ha;Ju, Jin Young;Jo, Kae Jung;Kim, Soo Ok;Oh, In Jae;Kim, Yu Il;Kim, Young Chul;Kim, Sung Min;Song, Ho Chun;Bom, Hee Seung;Park, Kyung Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.589-596
    • /
    • 2003
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patients in the our nation with high incidence of tuberculoma. We could not exclude whether the SPN was benign or malignant by the change of the size at chest radiograph and findings of chest CT. Recently, positron emission tomography(PET) have been tried as the differential diagnostic method of SPN. We evaluated the efficacy of PET for differentiating malignant from benign SPN and the relationship between standardized uptake values(SUV) of PET and serum glucose. Method : Between January 2001 and July 2002, sixty-one patients with pulmonary nodule were examined by the chest CT and PET. The SPN has been finally diagnosed by the transthorasic needle aspiration and biopsy, bronchoscopic biopsy, and open lung biopsy. Results : Forty eight patients had a malignant nodule(23 squamous cell lung carcinoma, 16 adenocarcinoma, 9 small cell lung cancer) and thirteen patients had a benign nodule(3 tuberculoma, 9 inflammatory granuloma, 1 cryptococcosis). The mean size of malignant and benign nodule was 40.6 mm and 20.0 mm, respectively. All malignant nodules showed a marked increase in 18 fluorodeoxyglucose (FDG) uptake. Mean SUV of malignant was $9.52{\pm}5.20$ and benign nodule was $1.61{\pm}3.60$. There were false positive cases with an increase in 18-FDG uptake (2 tuberculoma, 1 inflammatory granuloma). The SUV of malignant nodule in diabetes patients has no difference in non diabetes patients($9.10{\pm}4.51$ vs $9.65{\pm}5.46$). The sensitivity and specificity of the PET scan for SPN were 100%, 77%, respectively. The positive and negative predictive values were 94% and 100%. Conclusion : PET scanning showed highly accurate result in differentiating the malignant and benign SPN. There were no significant differences between the SUV and serum glucose in the patients with lung cancer.

Usefulness of serum procalcitonin test for the diagnosis of upper urinary tract infection in children (소아 상부 요로감염의 진단을 위한 혈청 procalcitonin 검사의 유용성)

  • Kim, Dong Wook;Chung, Ju Young;Koo, Ja Wook;Kim, Sang Woo;Han, Tae Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.87-92
    • /
    • 2006
  • Purpose : It is difficult to make a distinction between lower urinary tract infection(UTI) and acute pyelonephritis(APN) during the acute phase of febrile UTI due to nonspecific clinical symptoms and laboratory findings, especially among young children. We measured the serum procalcitonin(PCT) in children with UTI to distinguish between acute pyelonephritis and lower UTI, and to determine the accuracy of PCT measurement compared with other inflammatory markers. Methods : Serum samples were taken from children who admitted with unexplained fever or were suspected of having UTI. 51 children(mean $12.2{\pm}11.4$ months) were enrolled in this study. Leukocyte counts, erythrocyte sedimentation rates(ESR) and C-reactive protein(CRP) were also measured. Renal parenchymal involvement was assessed by $^{99m}Tc$ DMSA scintigraphy in the first 7 days after admission. PCT was measured by immunoluminometric assay. Results : PCT values were significantly correlated with the presence of renal defects in children with UTI(n=16)($5.06{\pm}12.97{\mu}g/L$, P<0.05). However, PCT values were not significantly different between children with UTI without renal damage(n=18) and children without UTI(n=17). Using a cutoff of $0.5{\mu}g/L$ for PCT and 20 mm/hr for ESR, 20 mg/L for CRP, sensitivity and specificity in distinguishing between UTI with and without renal involvement were 81.3 percent and 88.9 percent for PCT 87.5 percent and 72.2 percent for ESR, and 87.5 percent and 55.6 percent for CRP, respectively. Positive and negative predictive values were 86.7 percent and 84.2 percent for PCT and 60.9 percent and 81.8 percent for CRP, respectively. Conclusion : In febrile UTI, PCT values were more specific than CRP, ESR and leukocyte count for the identification of patients who might develop renal defects.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Development and Evaluation of a Nutritional Risk Screening Tool (NRST) for Hospitalized Patients (입원환자의 영양불량위험 검색도구의 개발 및 평가)

  • Han, Jin-Soon;Lee, Song-Mi;Chung, Hye-Kyung;Ahn, Hong-Seok;Lee, Seung-Min
    • Journal of Nutrition and Health
    • /
    • v.42 no.2
    • /
    • pp.119-127
    • /
    • 2009
  • Malnutrition of hospitalized patients can adversely affect clinical outcomes and cost. Several nutritional screening tools have been developed to identify patients with malnutrition risk. However, many of those possess practical pitfalls of requiring much time and labor to administer and may not be highly applicable to a Korean population. This study sought to develop and evaluate a Nutrition Risk Screening Tool (NRST) which is simple and quick to administer and widely applicable to Korean hospitalized patients with various diseases. The study was also designed to generate a screening tool predictable of various clinical outcomes and to validate it against the Nutritional Risk Screening 2002 (NRS 2002). Electronic medical records of 424 patients hospitalized at a general hospital in Seoul during a 14-month period were abstracted for anthropometric, medical, biochemical, and clinical outcome variables. The study employed a 4-step process consisting of selecting NRST components, searching a scoring scheme, validating against a reference tool, and confirming clinical outcome predictability. NRST components were selected by stepwise multiple regression analysis of each clinical outcome (i.e., hospitalization period, complication, disease progress, and death) on several readily available patient characteristics. Age and serum levels of albumin, hematocrit (Hct), and total lymphocyte count (TLC) remained in the last model for any of 4 dependent variables were decided as NRST components. Odds ratios of malnutrition risk based on NRS 2002 according to levels of the selected components were utilized to frame a scoring scheme of NRST. A NRST score higher than 3.5 was set as a cut-off score for malnutrition risk based on sensitivity and specificity levels against NRS 2002. Lastly differences in clinical outcomes by patients' NRST results were examined. The results showed that the NRST can significantly predict the in-hospital clinical outcomes. It is concluded that the NRST can be useful to simply and quickly screen patients at high-nutritional risk in relation to prospective clinical outcomes.

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.

Diagnostic Value of Serum Cytokeratin 8, 18 and 19 in Lung Cancer (폐암에서 혈중 Cytokeratin 8, 18, 19의 진단적 가치)

  • Choi, Chang Min;Kim, Woo Jin;Oh, Jin Young;Kang, Young Ae;Yoo, Chul Gyu;Lee, Choon Taek;Kim, Young Whan;Han, Sung Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.4
    • /
    • pp.388-394
    • /
    • 2003
  • Background : Monoclonal antibodies directed against well-known epitopes on cytokeratin (CK) 8, 18 and 19 (Monototal) have been used in the development of a new diagnostic tool for lung cancer. In the mid-1990s, CK 19 fragments (Cyfra 21-1) became popular and widely used for such diagnosis. This is the first study specifically designed to compare these two markers. Method : The serum levels of CK 8, 18 and 19 were measured using two-site monoclonal/polyclonal immunoradiometric assay kit in 57 healthy adults and 289 patients who were admitted to Seoul National University Hospital from May to September, 2002. The lung cancer group comprised 129 primary lung cancer patients; 116 with non-small cell lung cancer(NSCLC) and 13 with small cell lung cancer (SCLC). The control group comprised 160 non-malignant pulmonary lung disease patients and 57 healthy adults. A total of 166 twin Monototal and Cyfra 21-1 serum assays were obtained; 76 with lung cancer, 70 with non-malignant pulmonary lung disease and 20 healthy adults. Results : The mean serum value of Monototal was $412.47{\pm}455.45U/L$ in NSCLC, $237.08{\pm}145.15U/L$ in SCLC, $126.54{\pm}95.72U/L$ in non-malignant pulmonary lung disease, and $63.68{\pm}31.66U/L$ in healthy adults. The serum values of the lung cancer groups were significantly higher than those of the control group (p<0.01). Using a cut off value of 188U/L, sensitivity and specificity was 66.4% and 81.9% in NSCLC, and 43.8% and 81.9% in SCLC, respectively. The serum levels of CK 8, 18 and 19 were higher in advanced NSCLC than in early stage disease. Conclusion : The serum levels of CK 8, 18 and 19 may be useful in the diagnosis of NSCLC.

Predictive Factors of Renal Scarring in Children with Acute Urinary Tract Infection (급성 요로감염 환아의 신장 반흔 예측요인)

  • Baik, Jun-Hyun;Park, Young-Ha;Hwang, Sung-Su;Jeon, Jung-Su;Kim, Sung-Hoon;Lee, Seong-Yong;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.245-253
    • /
    • 2003
  • Puorpose: The purpose of this study was to evaluate the usefulness of $^{99m}Tc$ DMSA scintigraphy on the dignosis of a renal scar in children with urinary tract infections. Materials and Methods: Eighty three patients were included in this study, who were diagnosed as the urinary tract infection on the basis of symptom, urinalysis and urine culture. $^{99m}Tc$ DMSA scintigraphy and voiding cystoureterography were peformed within 7days before the treatment in all patients. We classified the scintigraphic findings as follow s : 1 ; a large hypoactive upper or lower pole. 2 ; a small hypoactive area. 3 ; single defect resulting in localized deformity of the outlines. 4 ; deformed outlines in a small or normal sized kidney. 5 ; multiple defects. 6 ; diffuse hypoactive kidney without regional impairment. Follow-up scintigraphy was done at least 6 months after the initial study. When the abnormality on the initial scintigraphy was not completely resolved on the follow-up scan, the lesion was defined as containing a scar. Results: One hundred and fifteen renal units of 166 units(69.3%) showed abnormal findings on the DMSA scintigraphy. 65 units(56.5%) was diagnosed as containing renal scars on follow-up scintigraphies. Incidences of renal scar among renal units showing pattern 3, 4 and 5 on the initial scan was 75%, 78% and 78%, respectively. Whereas many of renal units showing 1, 2 and 6 pattern were recovered(65%, 76%, 50%). Sensitivity, specificity and accuracy of pattern-based DMSA scintigraphic findings on the diagnosis of renal scar was 76.9%, 85.1% and 81.9%, respectively. VUR was significantly associated with the renal scar when the initial DMSA shows unrecoverable findings(pattern 3, 4, 5). Odds ratio of the renal scar in a kidney showing unrecoverable initial scintigraphic findings was 19.1. Odds ratio in a kidney with mild or moderate-to-severe VUR was 3.5 and 14.4 respectively. Conclusion: In the urinary tract infection, renal scar was significantly developed in a kidney showing unrecoverable findings on the initial DMSA scan and VUR on voiding cystoureterography.

Construction of a Standard Dataset for Liver Tumors for Testing the Performance and Safety of Artificial Intelligence-Based Clinical Decision Support Systems (인공지능 기반 임상의학 결정 지원 시스템 의료기기의 성능 및 안전성 검증을 위한 간 종양 표준 데이터셋 구축)

  • Seung-seob Kim;Dong Ho Lee;Min Woo Lee;So Yeon Kim;Jaeseung Shin;Jin‑Young Choi;Byoung Wook Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1196-1206
    • /
    • 2021
  • Purpose To construct a standard dataset of contrast-enhanced CT images of liver tumors to test the performance and safety of artificial intelligence (AI)-based algorithms for clinical decision support systems (CDSSs). Materials and Methods A consensus group of medical experts in gastrointestinal radiology from four national tertiary institutions discussed the conditions to be included in a standard dataset. Seventy-five cases of hepatocellular carcinoma, 75 cases of metastasis, and 30-50 cases of benign lesions were retrieved from each institution, and the final dataset consisted of 300 cases of hepatocellular carcinoma, 300 cases of metastasis, and 183 cases of benign lesions. Only pathologically confirmed cases of hepatocellular carcinomas and metastases were enrolled. The medical experts retrieved the medical records of the patients and manually labeled the CT images. The CT images were saved as Digital Imaging and Communications in Medicine (DICOM) files. Results The medical experts in gastrointestinal radiology constructed the standard dataset of contrast-enhanced CT images for 783 cases of liver tumors. The performance and safety of the AI algorithm can be evaluated by calculating the sensitivity and specificity for detecting and characterizing the lesions. Conclusion The constructed standard dataset can be utilized for evaluating the machine-learning-based AI algorithm for CDSS.

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

Is it Possible to predict the Characteristics of Calcific Deposition in Calcific Tendinitis of Shoulder Joint? (단순 방사선 검사를 이용하여 석회성 건염에서 발생하는 석회 침착물의 성상에 대한 예측이 가능한가?)

  • Kim, Sung-Jae;Lee, Hee Jae;Lee, Kwang-Hyun;Park, Dong-Hyeok;Lee, Bong Geun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.77-83
    • /
    • 2014
  • Purpose: The purpose of current study was to evaluate the validity of the existing radiological classifications as a diagnostic modality for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint. For that purpose, we determined the inter-observer reliability for evaluating diagnostic precisions of the classification and also evaluated diagnostic accuracy of predicting the toothpaste type calcific deposition. Materials and Methods: We performed retrospective study with total 26 patients surgically treated with calcific tendinitis of the shoulder joint from March 2010 to October 2013. Two independent observers reviewed preoperative radiographs of shoulder joints, and classified the characteristics of calcific depositions according to the criteria of Gartner, DePalma and Patte. Cohen's kappa were calculated for each classifications to evaluate inter-observer reliability. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were determined for type of calcific depositions with Gartner type III, DePalma type I, and Patte type II for predicting toothpaste type calcific deposition. Results: The values of Cohen's kappa were the highest in the classification of Patte, 0.62, and the values for the classifications of DePalma and Gartner were 0.56 and 0.36, respectively. The sensitivities for predicting toothpaste type calcific deposition in Gartner Type III, DePalma type I and Patte type II were 83.3%, 91.7%, and 58.3%, respectively. Specificities were 85.7% 50.0% and 64%, positive likelihood ratios were 5.833, 1.833 and 1.633, negative likelihood ratios were 0.194, 0.167 and 0.648, and diagnostic odds ratios were 30.00, 11.00 and 2.52, respectively. Conclusion: There were no radiologic classifications of calcific tendinitis which has both high precision and accuracy. Further studies with other diagnostic modalities such as ultrasonography are needed for predicting characteristics of calcific deposition in calcific tendinitis of the shoulder joint.

  • PDF