• Title/Summary/Keyword: Sensitive Loads

Search Result 191, Processing Time 0.025 seconds

A Survey on the interruption costs for the sensitive industrial customers to the short duration interruption (순간정전에 민감한 산업수용가의 정전비용에 관한 조사연구)

  • Nam, Kee-Young;Choi, Sang-Bong;Ryoo, Hee-Suk;Lee, Jae-Duck;Jeong, Seong-Hwan;Kim, Dae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.90-92
    • /
    • 2005
  • This paper addresses the analysis of interruption costs and the studies made through the direct interview with Korean Industrial customers for the period of two years. It is conducted to evaluate the direct and short duration interruption costs resulting from local random electrical supply interruptions. The cost is evaluated by providing a designed questionnaire focused on the experience or the preparative actions which consumers predicted they would take. In the first phase, authors made a survey on all types of industry with 176 industrial customers and evaluated them as per standard industry classification (SIC). In that case, the evaluation data obtained are not so reasonable, because the number of sampled industries was small and the sampled industries were surveyed by being divided into 18 types. So, in the second phase the authors concentrated on only 4 types of 302 industries who have many and large sensitive loads to the short duration interruption.

  • PDF

Establishment of Rainfall and Contaminants Runoff Modeling System for the Joman River Watershed Using SWMM (SWMM을 이용한 조만강 유역 강우-오염물 유출모델링시스템 구축)

  • Lee, Yong-Chin;Yoon, Young-Sam;Lee, Nam-Joo
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.983-992
    • /
    • 2009
  • The purpose of the present study is to analyze pollutant runoff characteristics from non-point sources in Joman River basin. The present study contains analyzed results of rainfall and SS, BOD, COD, TN, TP runoff from Joman River basin. This study contains a sensitivity analysis of parameters that affect the simulation results of rainfall and pollutants runoff. Result of the sensitivity analysis shows that proportion of watershed and impervious areas is the most sensitive to peak discharge and total flowrate for rainfall runoff and that WASHPO is the most sensitive parameter for pollutants runoff. For parameter estimation and verification, flowrate and water quality is measured at the Kangdong Bridge in Haeban stream. A single rainfall event is use to perform parameter estimation and verification. Results of the present study show that total pollutant loads of Joman River basin is 11,600 ton of SS, 452 ton of BOD, 1,084 ton of COD, 515 ton of TN, and 49 ton of TP, respectively. In addition, it is found that contribution ratio of non point source and total source is 89% of SS, 63% of BOD, 61% of COD, 21% of TN, and 32% of TP, respectively.

Adaptive Overlay Network Management Algorithms for QoS sensitive Multimedia Services (멀티미디어 서비스의 품질 보장을 위한 오버레이 네트워크 관리 기법에 대한 연구)

  • Kim, Sung-Wook;Kim, Sung-Chun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.1 s.111
    • /
    • pp.81-86
    • /
    • 2007
  • New multimedia services over the cellular/WLAN overlay networks require different Quality of Service (QoS). Therefore, efficient network management system is necessary in order to provide QoS sensitive multimedia services while enhancing network performance. In this paper, we propose a new online network management scheme that implements bandwidth reservation, congestion and transmission control strategies. Our online approach to network management exhibits dynamic adaptability, flexibility, and responsiveness to the current traffic conditions in multimedia overlay networks. Simulation results indicate the superior performance of our proposed scheme to strike the appropriate performance balance between contradictory QoS requirements under widely varying diverse traffic loads.

Analysis of Time Domain Active Sensing Data from CX-100 Wind Turbine Blade Fatigue Tests for Damage Assessment

  • Choi, Mijin;Jung, Hwee Kwon;Taylor, Stuart G.;Farinholt, Kevin M.;Lee, Jung-Ryul;Park, Gyuhae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • This paper presents the results obtained using time-series-based methods for structural damage assessment. The methods are applied to a wind turbine blade structure subjected to fatigue loads. A 9 m CX-100 (carbon experimental 100 kW) blade is harmonically excited at its first natural frequency to introduce a failure mode. Consequently, a through-thickness fatigue crack is visually identified at 8.5 million cycles. The time domain data from the piezoelectric active-sensing techniques are measured during the fatigue loadings and used to detect incipient damage. The damage-sensitive features, such as the first four moments and a normality indicator, are extracted from the time domain data. Time series autoregressive models with exogenous inputs are also implemented. These features could efficiently detect a fatigue crack and are less sensitive to operational variations than the other methods.

Present State Analysis of Customers' Effect in Power Distribution System by Momentary Voltage Variation (배전계통의 순시전압변동에 의한 수용가측 영향의 현황 분석)

  • 김재철;윤상윤;오정환;임성정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.37-46
    • /
    • 1998
  • This paper analyzes the present state of customers' effect in distribution system by momentary voltage variation. Customers are becoming increasingly concerned about the quality of electric power. Most of all, the voltage magnitude quality is very important because it can have a direct effect on customers. Especially, according to the development of automatic process, momentary voltage variations result in the shutdown of sensitive loads such as electronic equipment, computer and magnetic contactor, and so on. To analyze the shutdown rate of customers' equipments by the momentary voltage variation, we present the CVEMA curve and he cumulative CVEA curve of each load type through the experiment for the customers' sensitive equipments. Also, we have surveyed customers' opinion by the questionnaire as "Survey of Power Quality" an then the results are reported.

  • PDF

Design and Feedback Performance Analysis of the Inverter-side LC Filters Used in the DVR System (DVR시스템에 사용되는 인버터부의 LC필터 설계와 피드백 성능분석)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.79-84
    • /
    • 2015
  • Voltage sags are considered the dominant disturbances affecting power quality. Dynamic voltage restorers(DVRs) are mainly used to protect sensitive loads from the electrical network voltage disturbances such as sags or swells and could be used to reduce harmonic distortion of ac voltages. The typical DVR topology essentially contains a PWM inverter with LC Filter, an injection transformer connected between the ac voltage line and the sensitive load, and a DC energy storage device. For injecting series voltage, the PWM inverter is used and the passive filter consist of inductor(L) and capacitor(C) for harmonics elimination of the inverter. However there are voltage pulsation responses by the characteristic of the LC passive filter that eliminate the harmonics of the PWM output waveform of the inverter. Therefore, this paper presented design and feedback performance of LC filter used in the DVRs. The voltage control by LC filter should be connected in the line side since this feedback method allows a relatively faster dynamic response, enabling the elimination of voltage notches or spikes in the beginning and in the end of sags and strong load voltage THD reduction. Illustrative examples are also included.

Large-scale Virtual Power Plant Management Method Considering Variable and Sensitive Loads (가변 및 민감성 부하를 고려한 대단위 가상 발전소 운영 방법)

  • Park, Yong Kuk;Lee, Min Goo;Jung, Kyung Kwon;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.225-234
    • /
    • 2015
  • Nowadays a Virtual Power Plant (VPP) represents an aggregation of distributed energy resource such as Distributed Generation (DG), Combined Heat and Power generation (CHP), Energy Storage Systems (ESS) and load in order to operate as a single power plant by using Information and Communication Technologies, ICT. The VPP has been developed and verified based on a single virtual plant platform which is connected with a number of various distributed energy resources. As the VPP's distributed energy resources increase, so does the number of data from distributed energy. Moreover, it is obviously inefficient in the aspects of technique and cost that a virtual plant platform operates in a centralized manner over widespread region. In this paper the concept of the large-scale VPP which can reduce a error probability of system's load and increase the robustness of data exchange among distributed energy resources will be proposed. In addition, it can directly control and supervise energy resource by making small size's virtual platform which can make a optimal resource scheduling to consider of variable and sensitive load in the large-scale VPP. It makes certain the result is verified by simulation.

Environmental Restoration and Water Quality Management Modeling of Coastal Area by Reuse of Treated Wastewater (하수처리수 재이용에 따른 하천과 해역의 환경복원 및 수질관리 모델링)

  • Lee, Dae-In;Yoon, Yang-Ho;Park, Il-Heum;Lee, Gyu-Hyong;Cho, Hyeon-Seo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.505-521
    • /
    • 2007
  • This study estimated response of water duality and pollutant behavior according to the discharge and reuse of treated wastewater by three-dimensional eco-hydrodynamic model, and suggest plan that water quality management and environmental restoration in the coastal area including urban stream of Yeosu, Korea. Dispersions of low-saline water and COD by treated wastewater loads (design facility capacity, about $110,000m^3/d$) were very limited in near of effluent site. Nutrients, however, increase compared to the other water quality factors, especially total nitrogen was very sensitive to input loads. When reuse some of treated wastewater to Yeondeung stream, nitrogen was big influence on estuarine water quality. Although current characteristics of treated wastewater such as discharge and water quality were negligible to the change of marine environment, effluent concentration of COD, TN and TP, especially 40% of TN, are reduced within the allowable pollutant loads for satisfy environmental capacity and recommended water duality criteria. Also, controls of input point/non-point sources to Yeondeung stream and base concentration of pollutants in coastal sea itself are very necessary.

Evaluation Scheme of Cryopump Performance for Gas Loads (기체부하에 대한 크라이오 펌프의 성능 평가 방안)

  • In, S.R.;Jeong, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.169-176
    • /
    • 2010
  • Cryopumps can provide economical profits with a relatively high pumping speed per size. However, it is somewhat doubtful that pumping performance of cryopums, which is very sensitive to the temperature of the adsorption panel, can be maintained or recovered fast for large continuous or impulsive gas loads. The official evaluation items indicating cryopump performance for gas loads are the maximum throughput and the crossover value. There are two other, unofficial but widely used, items, the Ar recovery time and gulp characteristics. Although these evaluation items look absolutely different with each other, there are close relations and even duplications in their test schemes. Therefore, it is necessary to study how to improve practically each test procedure, and combine or unify some procedures.

Test and Fabrication of the 1MJ Superconducting Magnetic Energy Storage System (1MJ급 초전도에너지저장시스템 제작 및 평가)

  • Kim, H.J.;Seong, K.C.;Cho, J.W.;Kim, S.W.;Bae, J.H.;Lee, E.Y.;Kwon, Y.K.;Ryu, K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.685-687
    • /
    • 2002
  • For several decades researches and developments on superconducting magnetic energy storage (SMES) system have been done for efficient electric power management. Korea Electrotechnology Research Institute(KERI) have developed of a 1MJ. 300kVA SMES System for improving power quality in sensitive electric loads. We developed the code for design of a SMES magnet. which could find the parameters of the SMES magnet having minimum amount of superconductors for the same stored energy. and designed the 1MJ SMES magnet by using it. This paper describes the design. fabrication and experimental results for the SMES magnet. cryostat, HTS current lead and power converter.

  • PDF