• 제목/요약/키워드: Sensitive Loads

검색결과 193건 처리시간 0.023초

Wind effects on a large cantilevered flat roof: loading characteristics and strategy of reduction

  • Fu, J.Y.;Li, Q.S.;Xie, Z.N.
    • Wind and Structures
    • /
    • 제8권5호
    • /
    • pp.357-372
    • /
    • 2005
  • Mean and extreme pressure distributions on a large cantilevered flat roof model are measured in a boundary layer wind tunnel. The largest peak suction values are observed from pressure taps beneath conical "delta-wing type" corner vortices that occur for oblique winds, then the characteristics and causes of the local peak suctions are discussed in detail. Power spectra of fluctuating wind pressures measured from some typical taps located at the roof edges under different wind directions are presented, and coherence functions of fluctuating pressures are also obtained. Based on these results, it is verified that the peak suctions are highly correlated with the conical vortices. Furthermore, according to the characteristics of wind loads on the roof, an aerodynamic solution to minimize the peak suctions by venting the leading edges and the corners of the roof is recommended. The experimental results show that the suggested strategy can effectively control the generation of the conical vortices and make a reduction of 50% in mean pressures and 25% in extreme local pressures at wind sensitive locations on the roof.

하천 수질모형 시스템의 안정성 및 민감도 분석 (Stability and Sensitivity Analysis of Stream Water Quality System Model)

  • 심순보;한재석
    • 물과 미래
    • /
    • 제21권4호
    • /
    • pp.407-414
    • /
    • 1988
  • 본 논문의 목적은 하천 수질모형 시스템이 안정성 및 해감도이론에 의해 이론적으로 어떻게 분석되며, 그 결과 모형화를 위한 수치분석의 신뢰성과 수질 매개변수의 변화에 따른 모형의 민감성을 입증하는 것이다. 무한 Fourier 급수를 이용하여 전개한 안정성이론은 유한차분법을 사용한 모형의 수치해법을 분석하는데 있고, 1부 선형상태벡터식으로 표현되는 민감도이론은 BOD 부하, 유량, 온도와 같은 수질배개변수의 변동효과를 이론적으로 분석하는데 사용되었고, 그 연구 결과는 하천 수질모형시스템의 신뢰성을 파악할 수 있음이 입증되었다.

  • PDF

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

Wind-tunnel tests on high-rise buildings: wind modes and structural response

  • Sepe, Vincenzo;Vasta, Marcello
    • Wind and Structures
    • /
    • 제18권1호
    • /
    • pp.37-56
    • /
    • 2014
  • The evaluation of pressure fields acting on slender structures under wind loads is currently performed in experimental aerodynamic tests. For wind-sensitive structures, in fact, the knowledge of global and local wind actions is crucial for design purpose. This paper considers a particular slender structure under wind excitation, representative of most common high-rise buildings, whose experimental wind field on in-scale model was measured in the CRIACIV boundary-layer wind tunnel (University of Florence) for several angles of attack of the wind. It is shown that an efficient reduced model to represent structural response can be obtained by coupling the classical structural modal projection with the so called blowing modes projection, obtained by decomposing the covariance or power spectral density (PSD) wind tensors. In particular, the elaboration of experimental data shows that the first few blowing modes can effectively represent the wind-field when eigenvectors of the PSD tensor are used, while a significantly larger number of blowing modes is required when the covariance wind tensor is used to decompose the wind field.

동적전압보상기의 전압제어를 위한 PLL 방식의 개선 (Improvement of PLL Method for Voltage Control of Dynamic Voltage Restorer)

  • 김병섭;최종우
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.936-943
    • /
    • 2009
  • Dynamic voltage restorer(DVR) is now more preferable enhancement than other power quality enhancement in industry to reduce the impact of voltage faults, especially voltage sags to sensitive loads. The main controllers for DVR consists of PLL(phase locked loop), compensation voltage calculator and voltage compensator. PLL detects the voltage faults and phase. Compensation voltage calculator calculates the reference voltage from the source voltage and phase. With calculated compensation voltage from PLL, voltage compensator restores the source voltage. If PLL detect ideal phase, compensation voltage calculator calculates ideal compensation voltage. Therefore, PLL for DVR is very important. This paper proposes the new method of PLL in DVR. First, the power circuit of DVR system is analyzed in order to compensate the voltage sags. Based on the analysis, new PLL for improving transient response of DVR is proposed. The proposed method uses band rejection filter(BRF) at q-axis in synchronous flame. In order to calculate compensation voltage in commercial instruments, the PQR theory is used. Proposed PLL method is demonstrated through simulation using Matlab-Simulink and experiment, and by checking load voltage, confirms operation of the DVR

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

Assessment of Seasonal Algae Variability in a Reservoir

  • Lee, Ju Young;Han, Mooyoung;Kim, Tschungil
    • Environmental Engineering Research
    • /
    • 제19권3호
    • /
    • pp.223-228
    • /
    • 2014
  • We investigated seasonal algae variability and its influence on water quality in an agricultural reservoir. We observed that maximal total phosphorus (TP) loads were 1,715 kg from farmland in September, which changed the ecosystem in the reservoir. At this time, Dictyosphaerium pulchellum as green algae dominated. Aulacoseira ambigua as diatom became the most dominant from November 2010 to May 2011. The diatom was sensitive to water temperature. Microcystis spp. and Oscillatoria spp. as cyanobacteria were dominant during summer and fall, and sank down to the sediment during winter and spring. Increasing water temperature during summer causes anaerobic conditions in the sediment, leading to regrowth of cyanobacteria. With regard to the ratio of total nitrogen (TN) to TP, green algae and cyanobacteria were dominant at TN:TP ratios less than 20-30. Diatoms were dominant at TN:TP ratios greater than 30-40. Statistical analysis indicated that diatom growth was dependent on water temperature and TN concentration. TP concentration and water temperature were the key factors for the growth of cyanobacteria and green algae. From these results of this study, the management of land-use was an important parameter for improving water quality in the agricultural reservoir.

이산웨이블릿을 이용한 전력외란 측정 시스템 (Power disturbance measurement system using discrete wavelet transform)

  • 이진목;김홍균;최재호;이상훈
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.527-533
    • /
    • 2003
  • 최근 민감한 전자부하의 사용증대에 기인하여 전직의 안정도와 신뢰도에 대한 관심이 증대되고 있다. 이에 전력풀질문제가 근래에 있어 일반적인 중요한 과제로 대두되었다. 이러한 전력품질문제를 진단하기 위하여 실효치나 FFT 등의 기법을 이용한 많은 알고리즘이 연구되어 왔으나 모든 전력품질문제를 진단하기에는 아직도 미진한 상황이다. 본 논문은 이산 웨이블릿을 응용한 전력품질문제의 진단 방법을 제안하고 웨이블릿의 이론에 대한 기본적인 설명과 함께 제안된 이론의 타당성을 입증하기 위하여 실제 전력품질문제 진단시스템을 설계하고 실험결과를 제시하였다.

일축 압축하중 하 다공성 폴리우레탄폼의 재료비선형 거동 및 미세구조 변화 (Material Nonlinear Behavior and Microstructural Transition of Porous Polyurethane Foam under Uniaxial Compressive Loads)

  • 이은선;고태식;이치승
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.688-694
    • /
    • 2017
  • Porous materials such as polymeric foam are widely adopted in engineering and biomedical fields. Porous materials often exhibit complex nonlinear behaviors and are sensitive to material and environmental factors including cell size and shape, amount of porosity, and temperature, which are influenced by the type of base materials, reinforcements, method of fabrication, etc. Hence, the material characteristics of porous materials such as compressive stress-strain behavior and void volume fraction according to aforementioned factors should be precisely identified. In this study, unconfined uniaxial compressive test for two types of closed-cell structure polyurethane foam, namely, 0.16 and $0.32g/cm^3$ of densities were carried out. In addition, the void volume fraction of three different domains, namely, center, surface and buckling regions under various compressive strains (10 %, 30 %, 50 % and 70 %) were quantitatively observed using Micro 3D Computed Tomography(micro-CT) scanning system. Based on the experimental results, the relationship between compressive strain and void volume fraction with respect to cell size, density and boundary condition were investigated.

LS-DYNA 코드의 유체-구조 연성해석 기법을 이용한 자유낙하식 구명정의 가속도 응답 추정 (Estimation of Acceleration Response of Freefall Lifeboat using FSI Analysis Technique of LS-DYNA Code)

  • 배동명;자키;김학수;김주곤
    • 대한조선학회논문집
    • /
    • 제47권5호
    • /
    • pp.681-688
    • /
    • 2010
  • During certification of freefall lifeboats, it is necessary to estimate the injury potential of the impact loads exerted on the occupants during water entry. This paper focused on the numerical simulation to predict the acceleration response during the impact of freefall lifeboats on the water using FSI(Fluid-Structure Interaction) analysis technique of LS-DYNA code. FSI problems could be conveniently simulated by the overlapping capability using Arbitrary Lagrangian Eulerian(ALE) formulation and Euler-Lagrange coupling algorithm of LS-DYNA code. Through this study, it could be found that simulation results were in relatively good agreement with experimental ones in the acceleration peak values, and that the loading conditions were very sensitive to the acceleration responses by the experimental and simulation results.