• 제목/요약/키워드: Sensitive Equipment

Search Result 246, Processing Time 0.029 seconds

Hybrid-Biocomposite Material for Corrosion Prevention in Pipeline: a review

  • Suriani, M.J.;Nik, W.B. Wan
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.85-89
    • /
    • 2017
  • One of the most challenging issues in the oil and gas industry is corrosion assessment and management in subsea structures or equipment. At present, almost all steel pipelines are sensitive to corrosion in harsh working environments, particularly in salty water and sulphur ingress media. Nowadays, the most commonly practiced solution for a damaged steel pipe is to entirely remove the pipe, to remove only a localized damaged section and then replace it with a new one, or to cover it with a steel patch through welding, respectively. Numerous literatures have shown that fiber-reinforced polymer-based composites can be effectively used for steel pipe repairs. Considerable research has also been carried out on the repair of corroded and gouged pipes incorporated with hybrid natural fiber-reinforced composite wraps. Currently, further research in the field should focus on enhanced use of the lesser and highly explored hybrid-biocomposite material for the development in corrosion prevention. A hybrid-biocomposite material from renewable resource based derivatives is cost-effective, abundantly available, biodegradable, and an environmentally benign alternative for corrosion prevention. The aim of this article is to provide a comprehensive review and to bridge the gap by developing a new hybrid-biocomposite with superhydrophobic surfaces.

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

Effect of Hydrodemolition on Bonding Strengthof Structures Repaired or Rehabilitated with VES-LMC (VES-LMC로 보수.보강된 구조물의부착강도에 미치는 Hydrodemolition의 영향)

  • Kim, Seong-Kwon;Shim, Do-Sick;Lee, Bong-Hak;Yun, Kyung-Ku
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.397-400
    • /
    • 2006
  • Most of the civil structures in Korea and abroad have many kinds of damages when they are facing over-loaded traffics, long-term serviceability, and severe environmental conditions. Repair, rehabilitation, and retrofit are important for maintaining the serviceability of structures. In recent year, VES-LMC has been widely used as repair material for bridge deck repair and rehabilitation, because the VES-LMC has a various benefits such as traffic opening after 3 hours of curing, higher durability and bond strength. In case of any structure repaired or rehabilitated with VES-LMC, those were influenced capacity of bond between the base layer of slab and VES-LMC as well as physical properties of each other materials. The capacity of bond depended on purity of interface, micro cracks, curing of VES-LMC and so like. A kind of popular concrete repair technique, High pressure water jetting equipment is extremely efficient at removing damaged concrete. Removing damaged or poor quality concrete from sensitive structures such as bridge, tunnels, multi-story car parking decks and runways, using the high pressure water jetting could remove damaged or poor quality concrete remaining healthy and sound concrete. Accordingly, the purpose of this study is that it was to evaluate effect of hydrodemolition on the bond strength of VES-LMC overlay compared with effects of other method such as breaker, untreated. Also, it was evaluated the effect of surface moisture.

  • PDF

Experimental Investigation of the Electrostatic Discharge(ESD) Damage in Packaged Semiconductor Devices (패키지 반도체소자의 ESD 손상에 대한 실험적 연구)

  • Kim, Sang-Ryull;Kim, Doo-Hyun;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.94-100
    • /
    • 2002
  • As the use of automatic handling equipment for sensitive semiconductor devices is rapidly increased, manufacturers of electronic components and equipments need to be more alert to the problem of electrostatic discharges(ESD). In order to analyze damage characteristics of semiconductor device damaged by ESD, this study adopts a new charged-device model(CDM), field-induced charged model(FCDM) simulator that is suitable for rapid, routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. High voltage applied to the device under test is raised by the field of non-contacting electrodes in the FCDM simulator, which avoids premature device stressing and permits a faster test cycle. Discharge current and time are measured and calculated. The characteristics of electrostatic attenuation of domestic semiconductor devices are investigated to evaluate the ESD phenomena in the semiconductors. Also, the field charging mechanism, the device thresholds and failure modes are investigated and analyzed. The damaged devices obtained in the simulator are analyzed and evaluated by SEM. The results obtained in this paper can be used to prevent semiconductor devices form ESD hazards and be a foundation of research area and industry relevant to ESD phenomena.

A Study on Underwater Electro-magnetic Signature Prediction Due to Hull Corrosion of a Naval Ship (함정의 선체 부식에 의한 수중 전자기 신호 예측에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Ju, Hae-Sun;Jeon, Jae-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.177-185
    • /
    • 2012
  • Corrosion currents flow through the seawater due to the different electrochemical potential between a hull and a propeller under the draft line of ship. Additionally, in order to protect the hull and other sensitive anodic parts of the ship from corrosion, the corrosion protection system, called impressed current cathodic protection(ICCP) equipment has been installed in most naval ships. Those currents could be harmful to the electromagnetic silencing of the naval ship because sea mines are triggered by even a feeble field value. In this paper, we described electric and corrosion related magnetic fields by ship's galvanic corrosion and a corrosion protection system, and prediction results of electric and corrosion related magnetic fields at any depth for the model ship.

Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers (배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지)

  • 이복희;이동문;이수봉
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.94-99
    • /
    • 2003
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The transient overvoltages on low-voltage AC power distribution systems are induced by direct or indirect lightning return strokes, and they can cause damage and/or malfunction of the utility systems for home automation, office automation and factory automation as well as medical equipment. The behaviors of lightning overvoltages transferred through the transformer to the low voltage AC power distribution systems were experimentally investigated using a Marx generator. The surge voltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of distribution transformer and a custom service ground.

Frequency response of film casting process

  • Hyun, Jae-Chun;Lee, Joo-Sung;Jung, Hyun-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.91-96
    • /
    • 2003
  • The sensitivity of the product to the ongoing sinusoidal disturbances of the process has been investigated in the film casting of viscoelastic polymer fluids using frequency response analysis. As demonstrated for fiber spinning process (Jung et al., 2002; Devereux and Denn, 1994), this frequency response analysis is useful for examining the process sensitivity and the stability of extensional deformation processes including film casting. The results of the present study reveal that the amplification ratios or gains of the process/product variables such as the cross-sectional area at the take-up to disturbances exhibit resonant peaks along the frequency regime as expected for the systems having hyperbolic characteristics with spilt boundary conditions (Friedly, 1972). The effects on the sensitivity results of two important parameters of film casting, i.e., the fluid viscoelasticity and the aspect ratio of the casting equipment have been scrutinized. It turns out that depending on the extension thinning or thickening nature of the fluid, increasing viscoelasticity results in enlargement or reduction of the sensitivity, respectively. As regards the aspect ratio, it has been found that an optimum value exists making the system least sensitive. The present study also confirms that the frequency response method produces results that corroborate well those by other methods like linear stability Analysis and transient solutions response. (Iyengar and Co, 1996; Silagy et al., 1996; Lee and Hyun, 2001).

Correlation Analysis between Fatigue and Performance Shaping Factor for Alternation Worker's (Focused on the Semiconductor industry) (교대근무자의 피로와 수행영향인자 간의 상관관계 분석 (반도체 산업을 중심으로))

  • Yoon, Yong-Gu;Park, Peom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.11a
    • /
    • pp.303-316
    • /
    • 2008
  • For the past 25 years, Korean semiconductor has experienced enormous growth to be the highest production country in the world. Semiconductor industry is very time sensitive and driven by technology and process, and requires 24-hour full operation. The environment includes many different types of equipment, utilities, different gases and toxic chemicals as well as high voltage electricity. We have performed a survey with 3-shift engineers and workers in one line. The content of the questionnaire was about the correlation between fatigue and performance shaping factor (work type and work ability), and as a result we were able to deduce the correlation, p-value and the pattern of scatter plot. The shape of the model was made of 4 blocks for fatigue, 5 blocks for work type and 5 blocks for work ability, i. e. 14 blocks in total. As a conclusion to this findings, there was a correlation between fatigue and work type and work ability specifically in semiconductor industry, and we need some effort to reduce this.

  • PDF

Hair Loss Treatment Using Erbium:YAG Fractional Laser with Hair Growth-promoting Solution

  • Ahn, Dong Hyun
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.176-180
    • /
    • 2021
  • Several methods have been used to treat androgenetic hair loss, ranging from hair transplants to finasteride and minoxidil. Sometimes platelet-rich plasma injection therapy may be used to increase the satisfaction of patients who come to the hospital. However, some patients are sensitive to pain and are subjected to the inconvenience of requiring treatment after each blood sampling. The author had reported the effects of using a hair growth-promoting solution and JetpeelTM in parallel with a painless hair loss treatment method. However, the author was interested in more effective methods for patients with M-shaped or vertex hair loss who do not want to take medications or undergo hair transplant. In addition to the existing light-emitting diode therapy and electromagnetic field treatment, the author has made considered attempts to use various laser wavelength bands. However, the equipment for these methods can be expensive and are not suitable for patients who emphasize on cost-effectiveness. Therefore, the author used an existing reported method and a device based on the fractional erbium:YAG laser to provide the hair growth-promoting solution in parallel. The author chose a fractional 2940 nm-based laser device as a medium that could efficiently increase the growth phase, reduce the catagen phase, and facilitate intradermal product and drug delivery. As a result, there was a therapeutic benefit without any significant side effects such as redness and itching. Among the patients, the author reported the effects of the treatment on one patient with frontal M-shaped, mid, and vertex hair loss.

A Study on HVDC Underwater Cable Monitoring Technology Based on Distributed Fiber Optic Acoustic Sensors (분포형 광섬유 음향 센서 기반 HVDC 해저케이블 모니터링 기술 연구)

  • Youngkuk Choi;Hyoyoung Jung;Huioon Kim;Myoung Jin Kim;Hee-Woon Kang;Young Ho Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.199-206
    • /
    • 2023
  • This study presents a novel monitoring technique for underwater high-voltage direct current (HVDC) cables based on the Distributed Acoustic Sensor (DAS). The proposed technique utilizes vibration and acoustic signals generated on HVDC cables to monitor their condition and detect events such as earthquakes, shipments, tidal currents, and construction activities. To implement the monitoring system, a DAS based on phase-sensitive optical time-domain reflectometry (Φ-OTDR) system was designed, fabricated, and validated for performance. For the HVDC cable monitoring experiments, a testbed was constructed on land, mimicking the cable burial method and protective equipment used underwater. Defined various scenarios that could cause cable damage and conducted experiments accordingly. The developed DAS system achieved a maximum measurement distance of 50 km, a distance measurement interval of 2 m, and a measurement repetition rate of 1 kHz. Extensive experiments conducted on HVDC cables and protective facilities demonstrated the practical potential of the DAS system for monitoring underwater and underground areas.