• Title/Summary/Keyword: Sensing type

Search Result 1,087, Processing Time 0.026 seconds

Wireless Wearable GRF Sensing System for Continuous Measurements (연속적 데이터 획득을 위한 착용형 무선 지면 반력 측정 시스템)

  • Lee, Dongkwan;Jeong, Yongrok;Gu, Gwang Min;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.3
    • /
    • pp.285-292
    • /
    • 2015
  • This paper presents a wireless ground reaction force (GRF) sensing system for ambulatory GRF recording. The system is largely divided into three parts: force sensing modules based on optical sensor, outsole type frame, and embedded system for wireless communication. The force sensing module has advantages of the low height, robustness to the moment interference, and stable response in long term use. In simulation study, the strain and stress properties were examined to satisfy the requirements of the GRF sensing system. Four sensing modules were mounted on the toe, ball, and heel of foot shaped frame, respectively. The GRF signals were extracted using Micrpcontroller unit and transferred to the smart phone via Bluetooth communication. We measured the GRF during the normal walking for the validation of the continuous recording capability. The recorded GRF was comparable to the off the shelf stationary force plate.

In situ reduction of gold nanoparticles in PDMS matrices and applications for large strain sensing

  • Ryu, Donghyeon;Loh, Kenneth J.;Ireland, Robert;Karimzada, Mohammad;Yaghmaie, Frank;Gusman, Andrea M.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.471-486
    • /
    • 2011
  • Various types of strain sensors have been developed and widely used in the field for monitoring the mechanical deformation of structures. However, conventional strain sensors are not suited for measuring large strains associated with impact damage and local crack propagation. In addition, strain sensors are resistive-type transducers, which mean that the sensors require an external electrical or power source. In this study, a gold nanoparticle (GNP)-based polymer composite is proposed for large strain sensing. Fabrication of the composites relies on a novel and simple in situ GNP reduction technique that is performed directly within the elastomeric poly(dimethyl siloxane) (PDMS) matrix. First, the reducing and stabilizing capacities of PDMS constituents and mixtures are evaluated via visual observation, ultraviolet-visible (UV-Vis) spectroscopy, and transmission electron microscopy. The large strain sensing capacity of the GNP-PDMS thin film is then validated by correlating changes in thin film optical properties (e.g., maximum UV-Vis light absorption) with applied tensile strains. Also, the composite's strain sensing performance (e.g., sensitivity and sensing range) is also characterized with respect to gold chloride concentrations within the PDMS mixture.

Interaction Between the Quorum Sensing and Stringent Response Regulation Systems in the Enterohemorrhagic Escherichia coli O157:H7 EDL933 Strain

  • Oh, Kyung-Hwan;Cho, Seung-Hak
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.3
    • /
    • pp.401-407
    • /
    • 2014
  • Quorum sensing and the stringent response are well-known regulation systems for the expression of virulence genes in enterohemorrhagic Escherichia coli (EHEC). However, how these two systems interact is not well known. E. coli strains with mutations in two regulation systems, ${\Delta}luxS$ (ECM101) and ${\Delta}luxS{\Delta}relA{\Delta}spoT$ (ECM201), and the ${\Delta}luxS$ complement strain to ECM201 (ECM202) were created from EHEC O157:H7 EDL933 to investigate how the regulatory systems interact. The phenotypic changes of the mutant strains were characterized and compared with the wild type. The mutant strains exhibited no obvious growth defects, although acid resistance and cellular cytotoxicity were decreased significantly in all the mutant strains. Phenotypic characterization revealed that mutations in the stringent response system (ECM201 and ECM202) influenced the metabolic (defective utilization of arabinose and L-sorbose) and enzymatic activities (decreased trypsin activity, and increased ${\alpha}$-glucosidase activity). In contrast, the quorum sensing system mutant (ECM101) did not display these phenotypes. The motility of the quorum sensing system mutant (ECM101) was unchanged, but mutation in the stringent response system influenced the motility. Our results suggest that quorum sensing interacts with the stringent response regulation system.

Methodology to Measure Stress Within Sand Ground Using Force Sensing Resistors (박막형 압전 센서를 활용한 사질토 지반 지중 응력 측정 방법론)

  • Kim, Dong Kyun;Woo, Sang Inn
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.2
    • /
    • pp.115-123
    • /
    • 2024
  • Stress is an invisible physical quantity, necessitating the use of earth pressure cells for its measurement within theground. Traditional strain-gauge type earth pressure cells, due to their rigidity, can distribute stress within the ground and subsequently affect the accuracy of earth pressure measurements. In contrast, force sensing resistors are thin and flexible, enabling the minimization of stress disturbance when measuring stress within the ground. This study developed a system that utilizes force sensing resistors to measure ground stress. It involved constructing a soil chamber for calibrating the force sensing resistors, assessing the variability of measurements from resistors embedded in sand ground, and verifying the attachment of pucks to the sensing area of the resistors.

VALIDITY OF NDVI-BASED BIOPHYSICAL PARAMETERS FOR ECOSYSTEM MODELS

  • Lee, Kyu-Sung;Jang, Ki-Chang;Kim, Tae-Geun;Lee, Seung-Ho;Cho, Hyun-Guk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.543-546
    • /
    • 2006
  • NDVI has been very frequently used to estimate several biophysical parameters that are required for ecosystem models. Leaf area index (LAI), canopy closure, and biomass are among those biophysical parameters that are estimated by empirical relationship with NDVI. However, the type of remote sensing signals (raw DN value, at-sensor radiance, atmospherically corrected reflectance) used can vary the calculation of NDVI. In this study, we tried to attempt to compare the influence of NDVI linked with forest LAI for the watershed-scale ecosystem models to estimate evapotranspiration. Landsat ETM+ data were used to obtain various NDVI values over the study area in central Korea. The NDVI-based LAI and the resultant evapotranspiration estimation were greatly varied by the remote sensing signal applied.

  • PDF

수직형 마이크로 자이로스코프의 연성 진동과 영점 출력

  • 이승엽;전도영;김택현
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.880-885
    • /
    • 2000
  • In a verical type, vibratory gyroscope, the coupled motion between the reference and sensing vibrations causes the zero-point output which means non-zero sensing vibration without angular velocity. This structural coupling leaks to an inherent discrepancy between the natural frequencies of the reference and sensing oscillations, causing the degradation of the sensing performance and dynamic stability. In this paper, the dynamic characteristics associated the coupling phenomenon are theoretically analyzed. Effects of reference frequency and coupling factor on the rotational direction and amplitude of elliptic oscillation are studied. A technique to predict the existence of curve veering of crossing in frequency trajectories is introduced to apply the design of micro gyroscopes with decoupled structures.

  • PDF

Development of Weight Sensing Unit of Fruit Weight Grader Using Load Cell (중량선과기(重量選果機)의 중량감지부(重量感知部) 개선(改善)에 관(關)한 연구(硏究))

  • Kim, H.S.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.358-370
    • /
    • 1993
  • In Korea, fruit grading has been mainly done manually, and manual grading depends on human sense. Thus it is subjected to human error and is not always as consistent as would be desired. Therefore, a study on the development of fruit grader was initiated to improve the consistency of fruit grading. The sensitivity for fruit weight of the conventional spring type weight grader has a tendency to decrease by physical characteristics of spring which is used as a weight sensing unit. This study was carried out to develop weight measuring device for establishing the base of weight sensing unit of electronic weight grader. This device consists of a weight sensor using load cell, data acquisition system, and a microcomputer containing program to calculate fruit weight. The weight measuring device using load cell was developed to increase sensitivity of fruit weight. The result of this study showed that the weight sensing unit of electronic weight grader contributed to the improvement of performance of weight measuring device.

  • PDF

Projectile's Velocity Effect for Voltage Induced at Sensing Coil for Applying to Air Bursting Munition

  • Ryu, Kwon-Sang;Shin, Jun-Goo;Jung, Kyu-Chae;Son, Derac.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • We designed a model composed of a ring type magnet, a yoke, and a sensing coil embedded in a projectile for simulating the muzzle velocity. The muzzle velocity was obtained from the master curve for the induced voltage at sensing coil and the velocity as the projectile pass through the magnetic field. The induced voltage and the projectile's velocity are fitted by the $2^{nd}$ order polynomial. The skin effect difference between projectiles which consist of aluminum-aluminum and aluminum-steel was small. The projectile will surely be burst at the pre-determined target area using the flight time and the projectile muzzle velocity calculated from the voltage induced at the sensing coil on the projectile.

Enhancing Gas Response Characteristics of Mixed Metal Oxide Gas Sensors

  • Balamurugan, Chandran;Song, Sun-Ju;Kim, Ho-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.1-20
    • /
    • 2018
  • Semiconducting nanomaterials have attracted considerable interest in recent years due to their high sensitivity, selectivity, and fast response time. In addition, for portable applications, they have low power consumption, lightweight, simple in operation, a low maintenance cost. Furthermore, it is easy to manufacture microelectronic sensor structures with metallic oxide sensitive thin layers. The use of semiconducting metal oxides to develop highly sensitive chemiresistive sensing systems remains an important scientific challenge in the field of gas sensing. According to the sensing mechanisms of gas sensors, the overall sensor conductance is determined by surface reactions and the charge transfer processes between the adsorbed species and the sensing material. The primary goal of the present study is to explore the possibility of using semiconducting mixed metal oxide nanostructure as a potential sensor material for selective gases.

Hydrogen sensing of Nano thin film and Nanowire structured cupric oxide deposited on SWNTs substrate: A comparison

  • Hoa, Nguyen Duc;Quy, Nguyen Van;O, Dong-Hun;Wei, Li;Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.52.1-52.1
    • /
    • 2009
  • Cupric oxide (CuO) is a p-type semiconductor with band gap of ~1.7 eV and reported to be suitable for catalysis, lithium-copper oxide electrochemical cells, and gas sensors applications. The nanoparticles, plates and nanowires of CuO were found sensing to NO2, H2S and CO. In this work, we report about the comparison about hydrogen sensing of nano thin film and nanowires structured CuO deposited on single-walled carbon nanotubes (SWNTs). The thin film and nanowires are synthesized by deposition of Cu on different substrate followed by oxidation process. Nano thin films of CuO are deposited on thermally oxidized silicon substrate, whereas nanowires are synthesized by using a porous thin film of SWNTs as substrate. The hydrogen sensing properties of synthesized materials are investigated. The results showed that nanowires cupric oxide deposited on SWNTs showed higher sensitivity to hydrogen than those of nano thin film CuO did.

  • PDF