• Title/Summary/Keyword: Sensible heat ratio

검색결과 49건 처리시간 0.028초

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

섬광계를 이용한 비균질 도시 지표에서의 현열속 산정 (LAS-Derived Determination of Surface-Layer Sensible Heat Flux over a Heterogeneous Urban Area)

  • 이상현
    • 대기
    • /
    • 제25권2호
    • /
    • pp.193-203
    • /
    • 2015
  • A large aperture scintillometer (LAS) was deployed with an optical path length of 2.1 km to estimate turbulent sensible heat flux (${\mathcal{Q}}_H$) over a highly heterogeneous urban area. Scintillation measurements were conducted during cold season in November and December 2013, and the daytime data of 14 days were used in the analysis after quality control processes. The LAS-derived ${\mathcal{Q}}_H$ show reasonable temporal variation ranging $20{\sim}160W\;m^{-2}$ in unstable atmospheric conditions, and well compare with the measured net radiation. The LAS footprint analysis suggests that ${\mathcal{Q}}_H$ can be relatively high when the newly built-up urban area has high source contribution of the turbulent flux in the study area ('northwesterly winds'). Sensitivity tests show that the LAS-derived ${\mathcal{Q}}_H$ are highly sensitive to non-dimensional similarity function for temperature structure function parameter, but relatively less sensitive to surface aerodynamic parameters and meteorological variables (temperature and wind speed). A lower Bowen ratio also has a significant influence on the flux estimation. Overall uncertainty of the estimated daytime ${\mathcal{Q}}_H$ is expected within about 20% at an upper limit for the analysis data. It is also found that stable atmospheric conditions can be poorly determined when the scintillometry technique is applied over the highly heterogeneous urban area.

Observational Study for the Thermal Environment Evaluation of Summertime over the Asphalt Pavement - Case Study in Daegu 2014 -

  • Kim, Hae-Dong;Kim, Sung-Rak;Kim, Baek-Jo
    • 한국환경과학회지
    • /
    • 제24권10호
    • /
    • pp.1265-1272
    • /
    • 2015
  • To investigate the thermal environment over the summertime asphalt pavements, an automatic weather observation system was installed at a parking lot paved with asphalt to observe various meteorological parameters and surface temperature from July 1 to September 30, 2014. Since the number of rainy days in summer of 2014 particularly after the mid July is more than that of average data, a ratio of daily peak surface temperature above $45^{\circ}C$ was 28% which was lower than the average. The observational data about hourly average surface temperature and various heat balance factors at days where daily peak surface temperature is above $45^{\circ}C$ are as follows: An hour that had the daily maximum temperature was around 15 pm and the value was $49^{\circ}C$ approximately. Net shortwave radiation was the highest at 12pm as $800W/m^2$ and much radiation of $500W/m^2$ was absorbed at the ground between 11am and 17pm. Sensible heat that was delivered from the ground to the atmosphere was evaluated as $200W/m^2$ between 10am and 19pm. underground transfer heat up to $100W/m^2$ was measured as negative from 19pm to the next day 8am, which indicated the lower atmosphere was heated at night.

종이 물성이 전열교환 엘리먼트 성능에 미치는 영향 (Effect of Paper Properties on the Performance of a Enthalpy Exchanger)

  • 김내현;조진표;송길섭;김동훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

군산항의 평균 열속 (Mean Heat Flux at Gunsan Harbor)

  • 최용규;조영조;최옥인;양원석
    • 한국수산과학회지
    • /
    • 제36권5호
    • /
    • pp.535-540
    • /
    • 2003
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDl) (1991-2001), mean heat fluxes were estimated at the Gunsan harbor Net heat flux was transported from the air to the sea surface during March to early September, and it amounts to $125\;Wm^{-2}$ in average daily during May to June. During the middle of September to February, the transfer of net heat flux was conversed from the sea surface to the air with $-125\;Wm^{-2}$ in mininum value in October. Short wave radiation was ranged from 50 to $248\;Wm^{-2}$ showing maxima in April to June. Long wave radiation was ranged from 25 to $92\;Wm^{-2}$ with mininum value in June to July. Sensible heat flux denoting negative values in April to August was ranged from -30 to $72\;Wm^{-2}.$ Latent heat flux was ranged from 15 to $82\;Wm^{-2}$ with maxima in August to September. The phase of heat exchange was changed from cooling to heating in the end of February, and from heating to cooling In the beginning of September. The advective term of heat flux showed minima in April to June and maxima in November. The ratio of temperature variations was 1.37 in the sea surface process and the horizontal process by advection. This indicates that the main factor in variation of temperature at Gunsan harbor is the heat exchange process through the sea surface from the air.

종이 물성에 따른 판형 전열교환기의 성능 (Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties)

  • 김내현;조진표;송길섭;김동훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

열수지를 활용한 서울시 열환경 개선을 위한 공간 유형화 (Spatial Typification based on Heat Balance for Improving Thermal Environment in Seoul)

  • 권유진;안새결;이동근;윤은주;성선용;이기승
    • 국토계획
    • /
    • 제53권7호
    • /
    • pp.109-126
    • /
    • 2018
  • The purpose of this study is to identify the spatial types for thermal environment improvement considering heat flux and its spatial context through empirical orthodox formulas. First, k-means clustering was used to classify values of three kinds of heat flux - latent, sensible and storage heat. Next, from the k-means clustering, we defined a type of thermal environment (type LHL) where improvement is needed for more comfortable and pleasant thermal environment in the city, among the eight types. Lastly, we compared and analyzed the characteristics of each classified thermal environmental types based on land cover types. From the study, we found that the ratio of impervious surfaces, roads, and buildings of the type LHL is higher than those of the type HLH (relatively thermal comfort environment). In order to improve the thermal environment, the following contents are proposed to urban planners and designers depending on the results of the study. a) Increase the green zone rate by 10% to reduce sensible heat; b) Reduce the percentage of impermeable surfaces and roads by 10% ; c) Latent heat increases when water and green spaces are expanded. This study will help to establish a minimum criterion for a land cover rate for the improvement of the urban thermal environment and a standard index for the thermal environmental improvement can be derived.

HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a)

  • 김영중;임장순
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.3-11
    • /
    • 1997
  • 열펌프건조기는 증발기에 의한 냉각및 감습기능과 응축기에 의한 가열기능을 대류형건조기와 연계시킴으로써 필연적 손실로 분류되던 배기가 갖고 있는 현열과 잠열을 회수하여 재활용할 수 있는 이점이 있다. 본 연구에서는 HFC134a를 냉매로 사용한 배치형(batch type) 열펌프건조기를 설계제작하여 건조실의 유지온도, 공기의 바이패스비(bypass ratio), 냉매의 과열도를 일정하게 유지하고 정면풍속(face velocity)과 압축기속도를 변화시켜 건조기의 성능을 분석하였으며 정면풍속의 증가에 따라 열펌프의 성적계수는 증가하나 SMER(Specific Moisture Extraction Rate)은 감소하였다.

  • PDF

곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究) (Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer)

  • 금동혁;이용국;이규승;한종호
    • Journal of Biosystems Engineering
    • /
    • 제9권2호
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

건물군 조건이 도시 열환경에 미치는 영향에 관한 정량적 검토 (Quantitative Study on the Effect of the Building Composition on the Urban Thermal Environment)

  • 여인애;카마타요코;이정재;윤성환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.180-183
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate was analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1)The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. (2)Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature.

  • PDF