• 제목/요약/키워드: Self-testing

Search Result 843, Processing Time 0.028 seconds

Built-in self-testing techniques for path delay faults considering hamming distance (Hamming distance를 고려한 경로 지연 고장의 built-in self-testing 기법)

  • 허용민
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.807-810
    • /
    • 1998
  • This paper presents BIST (Built-in self-test) techniques for detection of path delay faults in digital circuits. In the proosed BIST schemes, the shift registers make possible to concurrently generate and compact the latched test data. Therefore the test time is reduced efficiently. By reordering the elements of th shifte register based on the information of the hamming distance of each memory elements in CUt, it is possible to increase the number of path delay faults detected robustly/non-robustly. Experimental results for ISCAS'89 benchmark circuits show the efficiency of the proposed BIST techniques.

  • PDF

Comparison of Detection Sensitivity for Human Papillomavirus between Self-collected Vaginal Swabs and Physician-collected Cervical Swabs by Electrochemical DNA Chip

  • Nilyanimit, Pornjarim;Wanlapakorn, Nasamon;Niruthisard, Somchai;Takahashi, Masayoshi;Vongpunsawad, Sompong;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10809-10812
    • /
    • 2015
  • Background: Human papillomavirus (HPV) DNA testing is an effective method to screen for precancerous changes in the cervix. Samples from self-collection rather than Pap smear can potentially be used to test for HPV as they are more acceptable and preferred for use in certain settings. The objective of this study was to compare HPV DNA testing from self-collected vaginal swabs and physician-collected cervical swabs. Materials and Methods: A total of 101 self-collected vaginal and physician-collected cervical swabs of known cytology from Thai women were tested by electrochemical DNA chip assay. The specimens were divided into 4 groups: 29 with normal cytology, 14 with atypical squamous cells of undetermined significance (ASCUS), 48 with low-grade squamous intraepithelial lesion (LSIL), and 10 with high-grade squamous intraepithelial lesion (HSIL). Results: Positive detection rates of HPV from self-collected swabs were similar to those from physician-collected swabs. Among specimens with abnormal cytology, HPV was found in 50% of self-collected swabs and 47.2% of physician-collected swabs. In specimens with normal cytology, 17.2% of self-collected swabs and 24.1% of physician-collected swabs were positive for HPV. Concordance was relatively high between results from self-collected and physician-collected samples. The most common HPV genotype detected was HPV 51. Conclusions: HPV DNA testing using self-collected swabs is a feasible alternative to encourage and increase screening for cervical cancer in a population who might otherwise avoid this important preventive examination due to embarrassment, discomfort, and anxiety.

Testing and Self Calibration of RF Circuit using MEMS Switches

  • Kannan, Sukeshwar;Kim, Bruce;Noh, Seok-Ho;Park, Se-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.882-885
    • /
    • 2011
  • This paper presents testing and self-calibration of RF circuits using MEMS switches to identify process-related defects and out of specification circuits. We have developed a novel multi-tone dither test technique where the test stimulus is generated by modulating the RF carrier signal with a multi-tone signal generated using an Arbitrary Waveform Generator (AWG) with additive white Gaussian noise. This test stimulus is provided as input to the RF circuit and peak-to-average ratio (PAR) is measured at the output. For a faulty circuit, a significant difference is observed in the value of PAR as compared to a fault-free circuit. Simulation is performed for various circuit conditions such as fault-free as well as fault-induced and their corresponding PARs are stored in the look-up table. This testing and self-calibration technique is exhaustive and efficient for present-day communication systems.

  • PDF

Self-Testing for FFT processor with systolic array architecture (시스토릭 어레이 구조를 갖는 FFT 프로세서에 대한 Self-Testing)

  • Lee, J.K.;Kang, B.H.;Choi, B.I.;Shin, K.U.;Lee, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1503-1506
    • /
    • 1987
  • This paper proposes the self test method for 16 point FFT processor with systolic array architecture. To test efficiently and solve the increased hardware problems due to built-in self test, we change the normal registers into Linear Feedback Shift Registers(LFSR). LFSR can be served as a test pattern generator or a signature analyzer during self test operation, while LFSR a ordering register or a accumulator during normal operation. From the results of logic simulation for 16 point FFT processor by YSLOG, the total time is estimated in about. 21.4 [us].

  • PDF

Cyclic behavior of self-centering braces utilizing energy absorbing steel plate clusters

  • Jiawang Liu;Canxing Qiu
    • Steel and Composite Structures
    • /
    • v.47 no.4
    • /
    • pp.523-537
    • /
    • 2023
  • This paper proposed a new self-centering brace (SCB), which consists of four post-tensioned (PT) high strength steel strands and energy absorbing steel plate (EASP) clusters. First, analytical equations were derived to describe the working principle of the SCB. Then, to investigate the hysteretic performance of the SCB, four full-size specimens were manufactured and subjected to the same cyclic loading protocol. One additional specimen using only EASP clusters was also tested to highlight the contribution of PT strands. The test parameters varied in the testing process included the thickness of the EASP and the number of EASP in each cluster. Testing results shown that the SCB exhibited nearly flag-shape hysteresis up to expectation, including excellent recentering capability and satisfactory energy dissipating capacity. For all the specimens, the ratio of the recovered deformation is in the range of 89.6% to 92.1%, and the ratio of the height of the hysteresis loop to the yielding force is in the range of 0.47 to 0.77. Finally, in order to further understand the mechanism of the SCB and provide additional information to the testing results, the high-fidelity finite element (FE) models were established and the numerical results were compared against the experimental data. Good agreement between the experimental, numerical, and analytical results was observed, and the maximum difference is less than 12%. Parametric analysis was also carried out based on the validated FE model to evaluate the effect of some key parameters on the cyclic behavior of the SCB.

Influencing Factors of Intention of Undergoing Pap Testing among Unmarried Nurses (미혼 간호사의 Pap 검진의도 영향요인)

  • Kim, Hae Won
    • Women's Health Nursing
    • /
    • v.20 no.3
    • /
    • pp.225-233
    • /
    • 2014
  • Purpose: This study was to assess the intention of undergoing Pap testing and to identify influencing factors of HPV knowledge and their attitude related to Pap test by sexual activity among unmarried nurses. Methods: A cross sectional survey design was employed, utilizing a self-administered questionnaire amongst 343 unmarried nurses. Descriptive statistics was utilized to analyze data and inferential statistics used an independent-t test and ${\chi}^2$ test for the differences in measurement variables, and odds ratios for factors on intention of Pap testing by sexual activity. Results: Nurses not sexually active were significantly higher in intention of Pap testing (${\chi}^2$=40.15, p<.001) and influencing factors of HPV knowledge (t=3.93, p=.048) than did nurses who were sexually active. Factors influencing intention were regularity of the breast self-examination (Adjusted Odds Ratio [AOR]=4.20, 95% Confidence Interval [CI]=1.93~9.17), HPV knowledge (AOR=2.49, 95% CI=1.36~4.56), and attitudes toward the Pap test(AOR=2.33, 95% CI=1.25~4.34) amongst nurses who never had sexual experience. Conclusion: It is necessary to minimize negative attitudes of Pap testing and to increase HPV knowledge in order to improve intention of Pap testing for women who were not sexually active. More focus would be given to sexually active women to get Pap tested as a preventive measure for cervical cancer.

ALU Design & Test for 32-bit DSP RISC Processors (32비트 DSP RISC 프로세서를 위한 ALU 설계 및 테스트)

  • 최대봉;문병인
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1169-1172
    • /
    • 1998
  • We designed an ALU(Airthmetic Logic Unit) with BIST(Built-In Self Test), which is suitable for 32-bit DSP RISC processors. We minimized the area of this ALU by allowing different operations to share several hardware blocks. Moreover, we applied DFT(Design for Testability) to ALU and offered Bist(Built-In Self-Test) function. BIST is composed of pattern generation and response analysis. We used the reseeding method and testability design for the high fault coverage. These techniques reduce the test length. Chip's reliability is improved by testing and the cost of testing system can be reduced.

  • PDF

Built-in self test for testing neighborhood pattern sensitive faults in content addressable memories (Content addressable memory의 이웃패턴감응고장 테스트를 위한 내장된 자체 테스트 기법)

  • 강용석;이종철;강성호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.8
    • /
    • pp.1-9
    • /
    • 1998
  • A new parallel test algorithm and a built-in self test (BIST) architecture are developed to test various types of functional faults efficiently in content addressable memories (CAMs). In test mode, the read oepratin is replaced by one parallel content addressable search operation and the writing operating is performed parallely with small peripheral circuit modificatins. The results whow that an efficient and practical testing with very low complexity and area overhead can be achieved.

  • PDF

Accuracy of Self-Checked Fecal Occult Blood Testing for Colorectal Cancer in Thai Patients

  • Lohsiriwat, Varut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7981-7984
    • /
    • 2014
  • Purpose: Colorectal cancer (CRC) screening with fecal occult blood testing (FOBT) has been associated with a reduction in CRC incidence and CRC-related mortality. However, a conventional FOBT requires stool collection and handling, which may be inconvenient for participants. The EZ-Detect$^{TM}$ (Siam Pharmaceutical Thailand) is a FDA-approved chromogen-substrate based FOBT which is basically a self-checked FOBT (no stool handling required). This study aimed to evaluate the accuracy of EZ-Detect for CRC detection. Methods: This prospective study was conducted in the Faculty of Medicine, Siriraj Hospital, Bangkok, Thailand between November 2013 and May 2014. Some 96 patients with histologically-proven CRC and 101 patients with normal colonoscopic findings were invited to perform self-checked FOBT according to the manufacturer's instructions. Results were compared with endoscopic and pathologic findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for CRC detection were calculated. Results: The present study revealed the sensitivity, specificity, PPV and NPV of this self-checked FOBT for CRC detection to be 41% (95% CI: 31-51), 97% (95% CI: 92-99), 93% (95% CI: 81-98) and 63% (95% CI: 55-70), respectively. The overall accuracy of the self-checked FOBT for identifying CRC was 70%. The sensitivity for CRC detection based on 7th AJCC staging was 29% for stage I, 32% for stage II and 50% for stage III/IV (P=0.19). The sensitivity was 33% for proximal colon and 42% for distal colon and rectal cancer (P=0.76). Notably, none of nine infiltrative lesions gave a positive FOBT. Conclusions: The self-checked FOBT had an acceptable accuracy of CRC detection except for infiltrative tumors. This home-administrated or 'DIY' do-it-yourself FOBT could be considered as one non-invasive and convenient tool for CRC screening.

Development of Self-compensated Technique for Evaluation of Surface-breaking Crack by Using Laser Based Ultrasound

  • Choi, Sang-Woo;Lee, Joon-Hyun;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.215-221
    • /
    • 2005
  • It is required to evaluate nondestructively depth of surface-breaking cracks in structures. In this paper, the self-compensated technique by laser-based ultrasound is used to measure the depth of surface-breaking defect. Optical generation of ultrasound produces a well defined pulse with reliable frequency content. It is broad banded and suitable for measurement of attenuation and scattering over a wide frequency range. The self-calibrated signal transmission data of surface wave shows good sensitivity as a practical tool far assessment of surface-breaking defect depth. It is suggested that the relationship between the signal transmission and crack depth can be used to predict the surface-breaking crack depths in structures.