• Title/Summary/Keyword: Self-diagnostic

Search Result 352, Processing Time 0.031 seconds

A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis (이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구)

  • ;;;Zeung Nam Bien
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

The subjective recognition of oral malodor and oral malodor self test (일부지역의 주관적인 구취에 대한 인식 및 구취 자가진단에 관한 연구)

  • Chun, Ju-Yeon;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.6
    • /
    • pp.871-879
    • /
    • 2014
  • Objectives: The purpose of the study was to investigate the appropriate management and implementation of the oral malodor prevention for the general people. Methods: A self-reported questionnaire was filled out by 420 subjects in Seoul and Gyeonggi Province from March to October, 2013. Except 19 copies, 401 copies were analyzed. The instrument of subjective oral malodor awareness and status was adapted from Yoon and Youn and partly modified. The questionnaire consisted of general characteristics(4 questions), oral malodor awareness(3 questions), oral malodor related characteristics(3 questions), self-diagnostic test of oral malodor(5 questions), and subjective oral malodor and health status(3 questions). Self-diagnostic test of oral malodor was score as yes(1 point) and no(0 point). The subjective oral malodor and health status scoring was done by Likert 5 scale. Cronbach alpha was 0.713 in the self-diagnostic test of oral malodor. Results: The self-recognition rate of oral malodor was 0.8%. When the level of oral malodor increased to 1 point, the self-test of oral malodor increased as the rate of 0.033(p<0.05). Conclusions: There existed no close correlation between subjective recognition of oral malodor and oral malodor self-test. Therefore, oral malodor should be measured by an expert counseling to make an accurate diagnosis. It is important to establish the appropriate oral malodor prevention program for the general people.

Factors Influencing Quality of Life of Alcoholics Anonymous Members in Korea (익명의 알코올중독자(AA) 모임 참여자의 삶의 질에 영향을 미치는 요인)

  • Yoo, Jae-Soon;Lee, Jongeun;Park, Woo-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.2
    • /
    • pp.305-314
    • /
    • 2016
  • Purpose: The purpose of this study was to determine quality of life (QOL) related factors in Alcoholics Anonymous (AA) members based on PRECEDE Model. Methods: A cross sectional survey was conducted with participants (N=203) from AA meeting in 11 alcohol counsel centers all over South Korea. Data were collected using a specially designed questionnaire based on the PRECEDE model and including QOL, epidemiological factors (including depression and perceived health status), behavioral factors (continuous abstinence and physical health status and practice), predisposing factors (abstinence self-efficacy and self-esteem), reinforcing factors (social capital and family functioning), and enabling factors. Data were analyzed using t-test, one way ANOVA, Tukey HSD test and hierarchical multiple regression analysis with SPSS (ver. 21.0). Results: Of the educational diagnostic variables, self-esteem (${\beta}=.23$), family functioning (${\beta}=.12$), abstinence self-efficacy (${\beta}=.12$) and social capital (${\beta}=.11$) were strong influential factors in AA members' QOL. In addition, epidemiological diagnostic variables such as depression (${\beta}=-.44$) and perceived health status (${\beta}=.35$) were the main factors in QOL. Also, physical health status and practice (${\beta}=.106$), one of behavioral diagnostic variables was a beneficial factor in QOL. Hierarchical multiple regression analysis showed the determinant variables accounted for 44.0% of the variation in QOL (F=25.76, p<.001). Conclusion: The finding of the study can be used as a framework for planning interventions in order to promote the quality of life of AA members. It is necessary to develop nursing intervention strategies for strengthening educational and epidemiological diagnostic variables in order to improve AA members' QOL.

Development of an Objective Structured Clinical Examination Checklist and a Post-Education Questionnaire for Musculoskeletal Ultrasound Training Focusing on Volar Wrist and Carpal Tunnel Syndrome

  • Cho, Eunbyul;Han, Young-Min;Kang, Yeonseok;Kim, Jae-Hyo;Shin, Min-Seop;Oh, Myungjin;Jung, Hyun-Jong;Jeon, Hyesoo;Cho, Nam Geun;Leem, Jungtae
    • Journal of Acupuncture Research
    • /
    • v.39 no.2
    • /
    • pp.105-114
    • /
    • 2022
  • Background: The objective structured clinical examination (OSCE) is used in the colleges of Korean Medicine, but few studies have validated the OSCE evaluation criteria or post-education questionnaires. Diagnostic ultrasound is used in Korean medicine treatment including acupuncture, acupotomy, and pharmacopuncture to increase the safety and efficacy of treatment. We aimed to develop and validate a OSCE checklist and questionnaire for diagnostic musculoskeletal ultrasound training. Methods: A OSCE checklist and rubric for diagnostic ultrasound training, and questionnaire was developed using literature research. Eight expert panelists verified each draft item in a single-round survey. Items with a content validity ratio (CVR) < 0.75 were excluded or modified to reflect the experts' opinions. Results: The OSCE checklist and rubric for diagnostic ultrasound training focusing on volar wrist and carpal tunnel syndrome included: 15 items revised according to CVR and expert opinions, the pre-examination procedure, structures to be identified by ultrasound, scans with 2 diagnostic criteria for carpal tunnel syndrome, an explanation of the exam results, and the post exam procedure. The questionnaire consisted of 15 items, including the overall evaluation of training, the effect of the OSCE, and the perception of the ultrasound. All 6 self-evaluation items were not revised, as they had a CVR of ≥ 0.75. Conclusion: An ultrasound OSCE for scanning the volar wrist and diagnosing carpal tunnel syndrome was developed using 15 validated tasks, 15 survey questions about ultrasound training, and 6 questions for self-evaluation. These results may be used in the future for education in diagnostic ultrasound.

Automatic Welding Carriage Control System with Self Diagnostic and Network functions (자가 고장진단 및 네트워크 기능을 보유한 자동용접 캐리지 제어 시스템)

  • 김종철;문형순;김종준;김용백;윤동섭;추정복
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.138-139
    • /
    • 2003
  • This paper describes the control system which was designed and implemented for a new automatic welding equipment. The system has the self diagnostic function which facilitates maintenance and repairs, and also has the network function via which the welding task data call be transmitted and the welding process data can be monitored.

  • PDF

Development and Validation of S.T.E.P+ Diagnostic Tool: Assessing Organizational Competence for Self-management in Daycare Centers (어린이집 자율관리를 위한 조직역량 진단도구(S.T.E.P+)의 개발 및 타당화)

  • Jeong-Won Kang;So-Young Park;Won-Seon Lee;Yoe-Jeong Lim
    • Korean Journal of Childcare and Education
    • /
    • v.20 no.2
    • /
    • pp.105-126
    • /
    • 2024
  • Objective: The study aimed to develop and validate a tool for assessing daycare center organizational competence and for autonomously managing childcare quality. Methods: Through literature review and expert reviews, items were derived and validated using the Content Validity Index. Data from a survey involving 216 directors and 509 teachers were analyzed using SPSS and AMOS to assess reliability and conduct confirmatory factor analysis. Results: Results revealed a 36-item diagnostic tool across four subcategories: shared values (6 items), training abilities (18 items), environmental support (6 items), and organizational promotion (6 items). A diagnostic tool named S.T.E.P+ was developed, named after the first letters of the four subfactors. Skewness and kurtosis were within normality assumptions. Good fit indices (CFI, TLI) and low SRMR and RMSEA values indicated a satisfactory model fit. Cronbach's α values showed high reliability for all factors. The tool enables autonomous diagnosis of childcare quality. Conclusion/Implications: This tool can effectively autonomously diagnose whether a daycare center is providing quality childcare.

Fabrication of IC Chip for Self-Diagnostic Function of a Eight-Beam Piezoresistive Accelerometer. (8빔 압저항형 가속도센서의 자기진단 기능을 위한 IC칩 제조)

  • Park, Chang-Hyun;Jun, Chan-Bong;Kang, Hee-Suk;Kim, Jong-Jib;Lee, Won-Tae;Sim, Jun-Hwan;Kim, Dong-Kwon;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.38-44
    • /
    • 1999
  • In this paper, we have constructed a self-diagnostic circuit which could detect erroneous signals in most cases that a eight-beam piezoresistive accelerometer were destroyed more than its one beam. To confirm the function of the circuit, PSPICE simulation was carried out. An IC chip was fabricated with a layout of KA 324 amplifier using a bipolar standard processing. After a package of the chip was sealed using a plastic package with 24 pins, the self-diagnostic characteristics were investigated. Then, the measured self-diagnostic characteristics of the circuit were compared with the PSPICE simulated result.

  • PDF

Effects of Diagnostic and Formative Assessment Using Equivalent Test on Elementary Science Classes : Focused on the 'Earth and Moon' Unit (동형검사를 활용한 진단 및 형성평가가 초등과학 수업에 미치는 효과 : '지구와 달' 단원을 중심으로)

  • Son, Jun Ho;Kim, Jonghee
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.4
    • /
    • pp.619-628
    • /
    • 2015
  • The purpose of this study is to find out the effects of the diagnostic and formative assessment on elementary science classes. For this purpose, we developed the diagnostic and formative assessment test and provided them to students before giving them the equivalent and learning achievement tests. The results are described as follows: First, for the science class that took the diagnostic assessment; the test provided help in improving the students' learning achievement. Second, for the science class that took the formative assessment; the test did not provide help in improving the students' learning achievement and in improving their openness to learning opportunity only to self-directed learning attitudes. Third, for the science class that were given both the diagnostic and formative assessment test; the tests provided help in improving the students' learning achievement. It also helped in improving their openness to learning opportunity, initiative for learning, and passion for learning except in problem-solving skills on self-directed learning attitude. Therefore, I recommend the utilization of the diagnostic and formative assessment tests be provided to students in order to improve learning achievement and self-directed learning attitudes in science classes.

Automatic Pipeline Welding System with Self-Diagnostic Function and Laser Vision Sensor

  • Kim, Yong-Baek;Moon, Hyeong-Soon;Kim, Jong-Cheol;Kim, Jong-Jun;Choo, Jeong-Bog
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1137-1140
    • /
    • 2005
  • Automatic welding has been used frequently on pipeline projects. The productivity and reliability are most essential features of the automatic welding system. The mechanized GMAW process is the most widely used welding process and the carriage and band system is most effective welding system for pipeline laying. This application-oriented paper introduces new automatic welding equipment for pipeline construction. It is based on cutting-edge design and practical welding physics to minimize downtime. This paper also describes the control system which was designed and implemented for new automatic welding equipment. The system has the self diagnostic function which facilitates maintenance and repairs, and also has the network function via which the welding task data can be transmitted and the welding process data can be monitored. The laser vision sensor was designed for narrow welding groove in order to implement higher accuracy of seam tracking and fully automatic operation.

  • PDF

Development of a sdms (Self-diagnostic monitoring system) with prognostics for a reciprocating pump system

  • Kim, Wooshik;Lim, Chanwoo;Chai, Jangbom
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1188-1200
    • /
    • 2020
  • In this paper, we consider a SDMS (Self-Diagnostic Monitoring System) for a reciprocating pump for the purpose of not only diagnosis but also prognosis. We have replaced a multi class estimator that selects only the most probable one with a multi label estimator such that we are able to see the state of each of the components. We have introduced a measure called certainty so that we are able to represent the symptom and its state. We have built a flow loop for a reciprocating pump system and presented some results. With these changes, we are not only able to detect both the dominant symptom as well as others but also to monitor how the degree of severity of each component changes. About the dominant ones, we found that the overall recognition rate of our algorithm is about 99.7% which is slightly better than that of the former SDMS. Also, we are able to see the trend and to make a base to find prognostics to estimate the remaining useful life. With this we hope that we have gone one step closer to the final goal of prognosis of SDMS.