• 제목/요약/키워드: Self-contained

검색결과 361건 처리시간 0.027초

P-코어 VCO를 사용한 10.525GHz 자체발진 혼합기의 설계 (Design of 10.525GHz Self-Oscillating Mixer Using P-Core Voltage Controlled Oscillator)

  • 이주흔;채상훈
    • 한국정보기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.61-68
    • /
    • 2018
  • 도플러 레이더에 응용할 목적으로 전압제어 발진기와 주파수 혼합기가 합쳐진 10.525GHz 자체발진 혼합기 반도체 IC 칩을 실리콘 CMOS 기술을 이용하여 설계하였다. 자체발진 혼합기에 포함된 p-코어 형태의 VCO는 송신신호에 포함된 잡음을 최소화한다. 이 잡음 최소화는 센싱 가능 거리를 늘여서 움직임 감지센서의 도달거리와 도달감도에 유리한 방향으로 작용한다. 위상잡음에 대한 시뮬레이션 결과 P-코어로 설계된 VCO는 1MHz 오프셋에서 -106.008dBc/Hz, 25MHz 오프셋에서 -140.735dBc/Hz의 잡음특성을 가짐으로써 N-코어 및 NP-코어로 설계된 VCO에 비하여 우수한 잡음 특성을 보였다. 본 연구에 의한 p-코어로 설계된 VCO를 이용하여 자체 발진 혼합기를 구현한다면 도달거리와 도달감도가 우수한 움직임 감지센서를 제작할 수 있을 것이다.

Desalination of geothermal water by membrane distillation

  • Gryta, M.;Palczynski, M.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.147-158
    • /
    • 2011
  • Membrane distillation process was used for desalination of hot (333 K) geothermal water, which was applied in the plant producing heating water. The investigated water contained 120 g salts/$dm^3$, mainly NaCl. The mineral composition was studied using an ion chromatography method. The obtained rejection of solutes was closed to 100%, but the small amounts of $NH_3$ also diffused through the membrane together with water vapour. However, the composition of obtained distillate allowed to use it as a makeup water in the heating water system. The geothermal water under study was concentrated from 120 to 286 g NaCl/$dm^3$. This increase in the solution concentration caused the permeate flux decline by a 10-20%. The geothermal water contained sulphates, which was subjected to two-fold concentration to achieve the concentration 2.4-2.6 g $SO{_4}{^{2-}}/dm^3$ and the sulphates then crystallized in the form of calcium sulphate. As a results, an intensive membranes scaling and the permeate flux decline was observed. The XRD analysis indicated that beside the gypsum also the NaCl crystallites were deposited on the membrane surfaces. The fresh geothermal water dissolved the mixed $CaSO_4$ and NaCl deposit from the membrane surface. This property can be utilized for self-cleaning of MD modules. Using a batch feeding of MD installation, the concentration of geothermal water was carried out over 800 h, without significant performance losses.

A Novel Multiplex-PCR Assay to Detect Three Non-Halal Meats Contained in Meatball using Mitochondrial 12S rRNA Gene

  • Cahyadi, Muhammad;Wibowo, Tommy;Pramono, Ahmad;Abdurrahman, Zakaria Husein
    • 한국축산식품학회지
    • /
    • 제40권4호
    • /
    • pp.628-635
    • /
    • 2020
  • The objective of this study was to detect three non-halal meat products consisted of dog, pork, and rat species in meatball using novel multiplex-PCR with 12S rRNA gene as target sites. A total of 33 self-made meatballs were used, and they were grouped into eleven types of meatball based on meat species origin contained in the meatballs. Each type consisted of three meatballs. Extraction of genomic DNA from the meatballs was used as a DNA template for simplex-, duplex-, and multiplex-PCR processes. The result of simplex-PCR, duplex-PCR, and multiplex-PCR showed that the 12S rRNA primer gene successfully amplified DNA for each species bovine, dog, pig, and rat, which are respectively indicated by 155, 244, 357, and 491 bp of DNA bands. In addition, multiplex-PCR with 12S rRNA gene primers can be uniquely and accurately used for detection bovine, dog, pig, and rat species on beef meatball in one reaction.

액상 연료 용 $kW_e$급 SOFC 시스템 사전 연구 및 개발 (Preliminary study and development of $kW_e$-class liquid fuel based SOFC system)

  • 윤상호;김선영;배중면;백승환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • We have developed a $kW_e$ class liquid fuel based solid oxide fuel cell (SOFC) system. Our final target is to develop the 1 $kW_e$ diesel based SOFC system for residential power generator(RPG). In this study, we present the conceptual design of SOFC system. System is composed of hot-box and cold-box. Planar typed SOFC stack, heat exchanger, combustor for stack tail gas, and fuel processor, such as fuel reformer and desulfurizer, are contained in the hot-box. And several balance of plants(BOP), such as fuel suppliers and controller, are contained in the cold-box. Before the SOFC system fabrication, we have already operated the selfsustaining fuel processor, and heat exchange of all heat-related components is simulated using ASPEN HYSYS, because heat maintenance and management in hot-box are important for stable operation of SOFC system. The self-sustained fuel processor was successfully operated for about 250 hours, and heat exchange is enough to operate the SOFC system.

  • PDF

영아전담공공가정 설계를 위한 기초연구 (A basic study on the Design of Institutional Household for Infants)

  • 두경자
    • 대한가정학회지
    • /
    • 제42권9호
    • /
    • pp.213-235
    • /
    • 2004
  • This study investigated the Infant Institutional Household (IIH) for the care of infants. The purpose was to provide basic information needed to raise Korea's birth rate and to design higher level nursing facilities which can satisfy working mothers who are presently offered few facilities. To achieve this purpose. IIM was divided into 7 sub-functional stations : planning-management, marketing, materials-management, business-management, man power-management, financial-management and control etc. The results are as follows : 1. Kind of facilities : Infants'(full responsibility) Institutional Household. 2. Number of infants : total 19 babies. 3. Ratio of infants to teachers : one to one (Contained assistance teachers) 4. Installing region : convenient traffic place - in Seoul. 5. Building site and kind : the first floor space of 60pyung (198㎡) in the Apartment complex which . contained many apartments of small size. 6. Nursing time : 24-hour day care in weekdays Age of object : age from 1month to 24months old babies(after his/her birth). 7. Kind of services and Cost : mother-like care, cost includes nursing-fee, a deposit and admission-fee. 8. Economic Condition and managing direction : pursuit limited profits with nursing-fee, admission-fee, a loan and national (or self -government of direct) supplementary funds.

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.233-239
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water. The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg O$_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg O$_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

  • PDF

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • 한국항해항만학회지
    • /
    • 제28권2호
    • /
    • pp.155-159
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water, The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg$O_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg $O_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

자기주도학습의 명시적 수업과 암묵적 수업에 대한 과학영재중학생의 평가에서 관찰되는 자기주도학습 요소 비교 (Comparison of Components of Self-directed Learning Discribed in the Students' Evaluation of Explicit Instruction and Implicit Instruction Regarding Self-directed Learning)

  • 최승언;김은숙
    • 영재교육연구
    • /
    • 제23권6호
    • /
    • pp.1077-1098
    • /
    • 2013
  • 자기주도학습을 암묵적으로 다루는 과학내용수업과 명시적으로 다루는 자율학습자수업으로 구성되어 있는 과학영재 프로그램에 참여한 중학생들에게 매 수업마다 평가의 일부로 수업에서 만족스러운 점을 서술하도록 하였다. 본 연구에서는 이 두 가지 수업에 대한 학생들의 평가에서 언급되는 자기주도학습 관련 요소들을 비교하였다. 첫째, 자기주도 학습 관련 하위요소의 대부분이 학생들의 평가에 언급되어 있었다. 수업 평가에서 만족스러운 이유를 조금이라도 구체적으로 서술한 경우, 거의 언제나 자기주도학습 관련 요소들을 포함하고 있었으며 분류기준에 있는 대부분의 하위요소가 언급되었다. 그러므로 대부분의 학생들이 자기주도학습 관련 요소들을 인식했고, 그에 대해서 만족스러워했음을 알 수 있다. 둘째, 두 가지 수업에 대한 평가에서 자주 언급되는 자기주도학습 관련 요소와 빈도에 차이가 있었는데, 자율학습자수업에 대한 평가에서 더 많은 요소들이 더 높은 비율로 언급되었다. 예를 들어 탐구기반 차원의 하위요소인 조별활동은 두 수업에서 동일하게 수행되지만, 자율학습자수업에 대한 평가에서 더 자주 언급되었다. 자율학습자수업 평가에서 더 자주 언급된 하위요소들로 인지차원에서 조직화, 계획, 점검, 동기차원에서 자아효능감과 성취가치, 행동차원에서 행동 통제 등이 있다. 한편 일반인지 차원의 하위요소인 지식의 정교화는 주로 과학내용수업 평가에서 언급되었으며, 동기차원의 하위요소인 목적지향은 두 수업에서 모두 많은 학생들이 언급하였으나 과학내용수업 평가에서 더 많은 학생들이 언급하였다. 따라서 두 가지 수업에서 학생들이 인식하는 자기주도학습 관련 요소들에 차이가 있으며 두 수업이 서로 보완적이며 두 가지 수업이 모두 필요한 것으로 보인다.

DRAM 집적공정 응용을 위한 전기도금법 증착 구리 박막의 자기 열처리 특성 연구 (A Study on the Self-annealing Characteristics of Electroplated Copper Thin Film for DRAM Integrated Process)

  • 최득성;정승현
    • 마이크로전자및패키징학회지
    • /
    • 제25권3호
    • /
    • pp.61-66
    • /
    • 2018
  • 본 연구에서는 DRAM 제조 집적공정의 금속배선으로 사용하는 구리의 자기 열처리(self-annealing) 후 박막 특성 변화에 대한 연구를 진행하였다. 구리를 증착하고 상온에서 시간이 경과하면 구리가 성장하여 결정체 크기 변화가 생기는데 이를 자기 열처리라고 부른다. 구리 금속의 증착은 전기 도금법(electroplating)을 사용하였다. 구리 도금액으로 유기 첨가물이 다른 두 가지 시료인 기준 도금액과 평가 도금액 두 용액에 대해 평가 하였다. 자기 열처리 시간이 경과함에 따라 시간에 대해 면 저항 값의 변화가 없는 영역과 이후 급격하게 떨어지는 구간으로 나누어지고 최종적으로 포화면 저항 값을 보인다. 최종적인 면 저항 값은 초기 값 대비 20% 개선 효과를 보인다. 평가 전해액의 자기 열처리 효과가 기준 용액 대비 더 빠른 시간 안에 이루어졌는데 이는 유기 첨가물의 차이 때문이다. 개선의 효과 분석으로 TEM 장비를 이용하여 결정체 변화를 관찰하였고 자기 열처리 공정에 의해 효과적인 결정체 성장이 이루어졌음을 발견했다. 또한 단면 TEM 측정 결과 자기 열처리 된 시료는 전류 방향으로의 결정체 경계면 숫자가 줄어드는 bamboo 구조를 보인다. 열적 열하 특성(thermal excursion characteristics) 측정 결과 고온 열처리 대비 자기 열처리 시료가 hillock 특성이 보이지 않고 이는 박막의 신뢰성 특성을 향상 시킨다. Electron backscattered diffraction (EBSD) 측정 결과 결정체가 $2{\mu}m$까지 성장한 결정체를 관찰하였고 스트레스에 의한 void를 억제하는데 유리한 (100) 면 비중이 증가하는 방향으로 결정체 성장이 이루어짐을 알 수 있다.

1kW 고체산화물 연료전지(SOFC) 시스템 설계 및 자열운전 (Design and Self-sustainable Operation of 1 kW SOFC System)

  • 이태희;최진혁;박태성;유영성;남석우
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.384-389
    • /
    • 2009
  • KEPRI (Korea Electric Power Research Institute) has studied planar type solid oxide fuel cell (SOFC) stacks using anode-supported cells and kW class co-generation systems for residential power generation. In this work, a 1 kW SOFC system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a SOFC stack made up of 48 cells, a fuel reformer, a catalytic combustor, and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation in that system. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. When the 1 kW SOFC stack was tested using hydrogen at $750^{\circ}C$, the stack power was about $1.2\;kW_e$ at 30 A and $1.6\;kW_e$ at 50 A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_e$ with hydrogen and $1.2\;kW_e$ with city gas respectively. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water.