• Title/Summary/Keyword: Selective solid-phase extraction

Search Result 38, Processing Time 0.022 seconds

Molecularly Imprinted Polymers for Solid-Phase Extraction of Sarcosine as Prostate Cancer Biomarker from Human Urine

  • Hashemi-Moghaddam, Hamid;Rahimian, Majid;Niromand, Bahman
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2330-2334
    • /
    • 2013
  • A highly selective molecularly imprinted polymer (MIP) for sarcosine, a cancer marker, was prepared and its use as solid-phase extraction (SPE) sorbent material was demonstrated. The MIP was prepared by a very simple procedure using methacrylic acid as functional monomer and a mixture acetonitrile/water (4/1, v/v) as porogen, overcoming in this way the problems usually related to the imprinting of biological polar compounds. The MIP was tested in batch experiments in order to evaluate its binding properties and then used as SPE sorbent for the selective clean-up and pre-concentration of sarcosine. The extraction protocol was successfully applied to the direct extraction of sarcosine from spiked human urine indicating that the MIP allowed sarcosine to be pre-concentrated while simultaneously interfering compounds were removed from the matrix.

Molecularly Imprinted Solid-Phase Extraction for Determination of Enrofloxacin and Ciprofloxacin in Chicken Muscle

  • Yan, Hong-Yuan;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1173-1178
    • /
    • 2008
  • A simple and sensitive high-performance liquid chromatographic method was developed for the simultaneous identification of enrofloxacin and its active metabolite ciprofloxacin in chicken muscle. Norflorxacin imprinted polymers synthesized in water-containing systems show high selectivity to enrofloxacin and ciprofloxacin in an aqueous environment. Using these water-compatible imprinted polymers as selective adsorbents in the solid-phase extraction of enrofloxacin and ciprofloxacin from chicken samples, the remaining biological matrix could be quickly washed out from the imprinted column while enrofloxacin and ciprofloxacin were selectively retained and enriched. Analytical separation was performed on a $C_{18}$ column using acetonitrile-water as a mobile phase and fluorescence detection. Good linearity was obtained from 0.8 to 500 ng/g (r > 0.998) with relative standard deviation of less than 3.9%. The mean recoveries of enrofloxacin and ciprofloxacin from chicken muscle were 80.6-94.5% and 77.8-91.8% at three different concentrations. The limits of determinations based on S/N=3 were 0.07 ng/g and 0.09 ng/g, which are below the maximum residue limits established in many countries.

Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector (Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kweon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

Study on Solid Phase Extraction and Spectrophotometric Determination of Nickel in Waters and Biological Samples

  • Hu, Qiu-Fen;Yang, Guan-Gyu;Huang, Zhang-Jie;Yin, Jia-Yuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.545-548
    • /
    • 2004
  • A sensitive, selective and rapid method for the determination of nickel based on the rapid reaction of nickel(II) with QADMAA and the solid phase extraction of the Ni(II)-QADMAA chelate with $C_{18}$ membrane disks has been developed. In the presence of pH 6.0 buffer solution and sodium dodecyl sulfonate (SDS) medium, QADMAA reacts with nickel to form a violet complex of a molar ratio of 1 : 2 (nickel to QADMAA). This chelate was enriched by solid phase extraction with $C_{18}$ membrane disks. An enrichment factor of 50 was obtained by elution of the chelates form the disks with the minimal amount of isopentyl alcohol. The molar absorptivity of the chelate was $1.32{\times}10^5L\;mol^{-1}cm^{- 1}$ at 590 nm in the measured solution. Beer's law was obeyed in the range of 0.01-0.6 ${\mu}$g/mL. This method was applied to the determination of nickel in water and biological samples with good results.

Study on the Solid Phase Extraction of Hg(II)-SBDTR Chelate with C18 Disks and Its Application to the Determination of Mercury in Tobacco and Tobacco Additive

  • Yang, Guan-Gyu;Xia, Zhen-Yuang;Wu, Yu-Ping;Sun, Han-Dong;Yin, Jia-Yuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.549-552
    • /
    • 2004
  • A sensitive, selective and rapid method has been developed for the determination of mercury based on the rapid reaction of mercury(II) with p-sulfobenzylidenethiorhodanine (SBDTR) and the solid phase extraction of the colored chelate with $C_{18}$ disks. In the presence of pH 3.5 sodium acetate-acetic acid buffer solution and Emulsifier-OP medium, SBDTR reacts with mercury(II) to form a red chelate of a molar ratio 1 : 2 (mercury to SBDTR). This chelate was prconcentrated by solid phase extraction with $C_{18}$ disks. An enrichment factor of 50 was achieved. The molar absorptivity of the chelate is $1.28{\times}10^5 L{\cdot}mol^{-1}{\cdot}cm^{-1}$ at 545 nm in measured solution. Beer's law is obeyed in the range of 0.01-3 ${\mu}$g/mL. The relative standard deviation for eleven replicates sample of 0.01 ${\mu}$g/mL is 1.65%. This method was applied to the determination of mercury in tobacco and tobacco additive with good results.

Study on Solid Phase Extraction and Spectrophotometric Determination of Vanadium with 2-(2-Quinolylazo)-5-Diethylaminophenol

  • Hu, Qiu-Fen;Yang, Guan-Gyu;Huang, Zhang-Jie;Yin, Jia-Yuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.263-266
    • /
    • 2004
  • A sensitive, selective and rapid method has been developed for the determination ${\mu}$g/L level of vanadium ion based on the rapid reaction of vanadium(V) with 2-(2-quinolylazo)-5-diethylaminophenol (QADEAP) and the solid phase extraction of the colored chelate with $C_{18}$ cartridge. The QADEAP reacts with V(V) in the presence of citric acid-sodium hydroxide buffer solution (pH = 3.5) and cetyl trimethylammonium bromide (CTMAB) medium to form a violet chelate of a molar ratio 1 : 2 (V(V) to QADEAP). This chelate was enriched by solid phase extraction with $C_{18}$cartridge and the enrichment factor of 50 was obtained by elution of the chelates from the cartridge with ethanol. The molar absorptivity of the chelate is $1.28 {\times}10^5L\;mol^{-1}cm^{-1}$ at 590 nm in the measured solution. Beer's law is obeyed in the range of 0.01-0.6 ${\mu}$g/mL. The detection limit is 0.04 ${\mu}$g/L in the original samples. This method was applied to the determination of vanadium(V) in water and biological samples with good results.

Utility of solid phase extraction for colorimetric determination of lead in waters, vegetables, biological and soil samples

  • Al-Mallah, Zakia;Amin, Alaa S.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.461-468
    • /
    • 2018
  • A highly sensitive, selective and rapid method for the determination of lead based on the reaction of lead (II) with 5-(4'-chlorophenylazo)-6-hydroxypyrimidine-2,4-dione (CPAHPD) and the solid phase extraction of the Pb(II)-CPAHPD complex with Amberlite XAD-2000 was developed, in the presence of pH 5.6 buffer solution and Triton X-114 medium. CPAHPD reacts with lead to form a violet complex with a molar ratio of 2:1 (CPAHPD to lead). This complex was enriched by the solid phase extraction with Amberlite XAD-2000. An enrichment factor of 500 was obtained by elution of the complex from the resin with a minimal amount of isopentyl alcohol(0.2 mL). In isopentyl alcohol medium,the molar absorptivity of the complex is $1.13{\times}10^6L\;mol^{-1}cm^{-1}$ at 647 nm. Beer's law is obeyed in the range of $5.0-160ng\;mL^{-1}$ in the measured solution. The relative standard deviation for 10 replicate samples of $50ng\;mL^{-1}$ level is 1.26%. The detection and quantification limits reaches 1.5 and $4.7ng\;mL^{-1}$ in the original samples. The presented procedure was successfully applied for determination of lead content in real samples such as vegetables, waters, biological and soil samples with satisfactory results.

Alternative Sample Preparation Techniques in Gas Chromatographic-Mass Spectrometric Analysis of Urinary Androgenic Steroids

  • Cho, Young-Dae;Choi, Man-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1315-1322
    • /
    • 2006
  • The following study describes the gas chromatography-mass spectrometry (GC-MS) based screening and confirmation analysis of urinary androgenic steroids. Four commercially available solid-phase extraction (SPE) cartridges, Serdolit PAD-1, Sep-pak $C_{18}$, amino-propyl, and Oasis HLB, and three different extractive organic solvents, diethyl ether, methyl tert-butyl ether (MTBE), and n-pentane, were tested for sample preparation. Overall, Oasis HLB combined with MTBE extraction provided the highest recoveries in 39 of 46 total androgenic steroids examined and it showed a good extraction yield (>82.1%) for polar steroids, such as metabolites of fluoxymesterone, oxandrolone, and stanozolol, which gave a poor recovery in both n-pentane (9.2-64.3%) and diethyl ether (22.2-73.6%) extractions. All SPE sorbents tested showed potential, because they were efficient in extraction for most or selective steroids. When applied to positive urine samples based on the results obtained, the present method allowed selective and sensitive analysis for detection of urinary androgenic steroids. The experiments showed that the high-resolution MS method is clearly more efficient than the low-resolution MS technique for the detection of many urinary steroids. However, comprehensive sample clean-up procedures also might be needed especially in confirmation analysis to increase detectability.

Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD) (HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kwon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

A Review on the Analytical Techniques for the Determination of Fluorine Contents in Soil and Solid Phase Samples (토양 및 고체시료 중 불소함량 측정기법)

  • An, Jinsung;Kim, Joo-Ae;Yoon, Hye-On
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.112-122
    • /
    • 2013
  • Current status of soil contamination with fluorine and its source were investigated. The basic principles and procedures of various techniques for the analysis of fluorine contents in soil and solid phase samples were summarized in this review. Analysis of fluorine in solid matrices can be achieved by two types of techniques: (i) UV/Vis spectrophotometer or ion selective electrode (ISE) analysis after performing appropriate extraction steps and (ii) direct solid analysis. As the former cases, the standard method of Korean ministry of environment, alkali fusion-ISE method, pyrohydrolysis, oxygen bomb combustion, aqua regia digestion-automatic analysis, and sequential extraction-ISE method were introduced. In addition, direct analysis methods (i.e., X-ray fluorescence spectrometry and proton induced gamma-ray emission spectrometry) and atomic spectrometry combining with the equipment for introducing solid phase sample were also reviewed. Fluorine analysis techniques can be reasonably selected through site-specific information such as matrix condition, contamination level, the amount of samples and the principles of various methods for the analysis of fluorine presented in this review.