• Title/Summary/Keyword: Selective addition

Search Result 821, Processing Time 0.028 seconds

A Study on the Total, Particle Size-Selective Mass Concentration of Airborne Manganese, and Blood Manganese Concentration of Welders in a Shipbuilding Yard (조선업 용접작업자의 공기 중 총 망간 및 입경별 망간 농도와 혈중 망간농도에 관한 연구)

  • Park, Jong Su;Kim, Pan Gyi;Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.472-481
    • /
    • 2015
  • Objectives: Welding is a major task in shipbuilding yards that generates welding fumes. A significant amount of welding in shipbuilding yards is done on steel. Inevitably, manganese is present in the base metals being joined and the filler wire being used and, consequently, in the fumes to which workers are exposed. The objective of this work was to characterize manganese exposure associated with work area, total and particle size-selective mass concentration, and compare the mass concentrations obtained using a three-piece cassette sampler, size-selective impactor sampler and blood manganese concentrations. Materials: All samples were collected from the main work areas at one shipbuilding yard. We used a three piece cassette sampler and the eight stage cascade impactor sampler for the airborne manganese mass concentration of total and all size fractions, respectively. In addition, we used the results of health examination of workers sampled for airborne manganese. Results: The oder of high concentration of airborne manganese in shipbuilding processes was as follows; block assembly, block erection, outfitting installation, steel cutting, and outfitting preparation. The percentages of samples that exceeded the OES of the ministry of employment and labor by the cassette sampling method was 12.5%, however 59.1% of sampled workers by the impactor sampling method exceeded the TLV of the ACGIH. Conclusions: Even though the manganese concentrations in blood of workers exposed to higher airborne manganese concentration were higher than among those exposed to lower concentrations, there was no difference in blood manganese concentrations among work duration. The data analyzed here by characterizing size-selective mass concentrations indicates that the inhaled manganese of welders in shipbuilding yards could be mostly manganese-containing respirable particle sizes.

Improvement of Image Scrambling Scheme Using DPSS(Discrete Prolate Spheroidal Sequence) and Digital Watermarking Application (DPSS(Discrete Prolate Spheroidal Sequence)를 이용한 영상 스크램블링 방식의 개선 및 디지털 워터마킹 응용)

  • Lee, Hye-Joo;Nam, Je-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1417-1426
    • /
    • 2007
  • As one of schemes to protect multimedia content. it is the selective encryption scheme to encrypt partially multimedia content. Compared AES(advanced encryption standard) of traditional encryption, the selective encryption scheme provides low security but is applicable to applications of multimedia content not to require high secrecy. In this paper, we improve the image scrambling scheme proposed by Van De Ville which scrambles an image without bandwidth expansion using DPSS(discrete prolate spheroidal sequence) to make it more secure based on Shujun's research which verifies the secrecy of Van De Ville's scheme. The proposed method utilizes an orthonormalized random matrix instead of Hadamard matrix for secret matrix and to add it for providing high secrecy against statistical attack or known-plaintext attack using some statistical property or estimate of secret matrix from a scrambled image. The experimental results show that the proposed method is more secure than the existing scheme. In addition, we show that the proposed method can be applied to access control or copy control of watermarking application.

  • PDF

An N-Channel Stop and Wait ARQ based on Selective Packet Delay Strategy in HSDPA Systems (HSDPA 시스템에서 선택적 지연 기반의 N-채널 SAW ARQ)

  • Park Hyung-Ju;Lim Jae-sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.896-905
    • /
    • 2005
  • In this paper, we propose a SPD(Selective Packet Delay) scheme to improve the performance of High-Speed Downlink Shared Channel(HS-DSCH) employing N-Channel Stop and Wait retransmission scheme in High Speed Downlink Packet Access(HSDPA) system. The proposed SPD coordinates packet transmissions according to the channel condition. When the channel condition is bad, packet transmission is forcedly delayed, and the designated time slot is set over to other users in good channel condition. Hence, the SPD is able to reduce the average transmission delay for packet transmission under the burst error environments. In addition, we propose two packet scheduling schemes called SPD-LDPF(Long Delayed Packet First) and SPD-DCRR(Deficit Compensated Round Robin) that are effectively combined with the SPD scheme. Simulation results show that the proposed scheme has better performance in terms of delay, throughput and fairness.

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Selective temporal error concealment method for H.264/AVC (H.264/AVC를 위한 선택적 시간축 에러 은닉 방법)

  • Jung Bongsoo;Choi Woongil;Jeon Byeungwoo;Kim Myung-Don;Choi Song-In
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.87-100
    • /
    • 2005
  • In this paper, we propose a new selective temporal error concealment algerian best suited for H.264/AVC. The proposed algorithm performs selective temporal error concealment depending on whether the lost block is at background or foreground. It the corrupted macroblock is decided as at background, then the simple temporal replacement is performed. Also we propose replacing a lost block at foreground with the selective average of respectively estimated blocks from the multiple reference frames. This paper supposes error-corrupted H.264/AVC video bitstreams over CDMA2000 (or UMTS) air interface. It is shown that under Flexible Macroblock Ordering (FMO) coding of H.264/AVC, the proposed algorithm provides PSNR gain up to 1.18dB compared to built-in algorithm in the K264/AVC test model. In addition, the proposed error concealment method has average PSNR improvement of 0.33dB compared with that under N-slice coding mode. The proposed algorithm also provides better subjective video quality than other conventional error concealment algorithms.

Miniaturized Frequency Selective Surface with a Scalability of Operating Frequency (동작 주파수 확장성을 갖는 소형화된 주파수 선택 표면구조 설계)

  • Lee, In-Gon;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.512-520
    • /
    • 2016
  • In this paper, a miniaturized frequency selective surface(FSS) for bandstop operation that provides stability for an angle of incidence and polarization is presented. The proposed miniaturized FSS has the unit cell of hexagonal structure with triangular loops and size of the unit cell is $0.081{\lambda}{\times}0.081{\lambda}$ at 2.5 GHz operating frequency, which is very small compared to operating wavelength. In addition, unlike the conventional design, which requires complicated design parameters, the proposed FSS is easily expanded to the desired operating frequency for 2~8 GHz, by controlling the specific design parameters. To validate the simulation results, the FSS structures having different operating frequencies, 2.5 GHz, 5 GHz and 8.2 GHz were designed, fabricated and measured. The comparisons between the simulation and the measured results show good agreement. The proposed miniaturized FSS can provide better frequency stability for different incidence angles and polarizations.

A hydrogen ion-selective membrane electrode based on N,N,N,N-Tetrabenzylethylenediamine as neutral carrier (N,N,N,N-Tetrabenzylethylenediamine 중성운반체를 이용한 수소 이온 선택성 막전극)

  • Jeong, Seong-Suk;Park, Myon-Yong;Chung, Koo-Chun;Cho, Dong-Hoe;Lee, Kyeong-Jae;Kim, Jae-Woo
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 1995
  • A PVC membrane ion-selective electrodes based on N,N,N,N-tetrabenzylethylenediamine as neutral carrier has been prepared by addition of plasticizers such as phthalates and sebacate and liphophillic additives such as NaTPB. The membrane electrodes were investigated to the electric resistance, response range to hydrogen ion and the interfering effect of alkali and alkline earth metals. A electric resistance hardly had on effect of plasticizers. In case of 0.7% NaTPB added to membrane, response of the electrodes were shown the values near to theoretical Nernstian slope and interferences by alkali and alkaline earth metal were few influenced. The performances of pH-selective electrodes were shown linerality to hydrogen ion between pH 2 and 10 in the presense of alkali and alkaline earth ions. Reproducibility and stability tests were shown good results in the same pH range.

  • PDF

Enhancement of Selective Removal of Nitrate Ions from a Mixture of Anions Using a Carbon Electrode Coated with Ion-exchange Resin Powder (이온교환수지 분말이 코팅된 탄소전극을 이용한 음이온 혼합용액에서 Nitrate 이온의 선택적 제거율 향상)

  • Yeo, Jin-Hee;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.49-54
    • /
    • 2013
  • We fabricated a composite carbon electrode to remove nitrate ions selectively from a mixed solution of anions. The electrode was fabricated by coating the surface of a carbon electrode with the nitrate-selective anion exchange resin (BHP55, Bonlite Co.) powder. We performed capacitive deionization (CDI) experiments on a mixed solution containing chloride, nitrate, and sulfate ions using a BHP55 cell constructed with the fabricated electrode. The removal of nitrate ions in the BHP55 cell was compared to that of a membrane capacitive deionization (MCDI) cell constructed with ion exchange membranes. The total quantity of ions adsorbed in BHP55 cell was $38.3meq/m^2$, which is 31% greater than that of MCDI cell. In addition, the number of nitrate adsorption in the BHP55 cell was $15.9meq/m^2$ (42% of total adsorption), 2.1 times greater than the adsorption in the MCDI cell. The results showed that the fabricated composite carbon electrode is very effective in the selective removal of nitrate ions from a mixed solution of anions.

Effect of Selective Withdrawal on the Control of Turbidity Flow and Its Water Quality Impact in Deacheong Reservoir (선택취수에 따른 대청호 탁수 조절효과 및 수질영향 분석)

  • Jung, Yong-Rak;Liu, Huan;Kim, Yu-Kyung;Ye, Lyeong;Chung, Se-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.601-615
    • /
    • 2007
  • A selective withdrawal method has been widely used to control the quality of water released from a stratified reservoir and to improve downstream ecosystem habitats. Recently, several existing reservoir withdrawal facilities have been modified to accommodate multi-level water intake capabilities in order to adapt the impact of long-term discharge of high turbidity flow. The purpose of this study was to assess the effect of selective withdrawal method on the control of downstream turbidity and its impact on water quality in Daecheong Reservoir. A laterally integrated two-dimensional hydrodynamic and eutrophication model, which was calibrated and validated in the previous studies, was applied to simulate the temporal variations of outflow turbidity with various hypothetical selective withdrawal scenarios. In addition, their impacts on the algal growth as well as water quality constituents were analyzed in three different spatial domains of the reservoir The results showed that the costly selective withdrawal method would provide very limited benefits for downstream turbidity control during two years of consecutive simulations for 2004-2005. In particular, an excessive withdrawal from the epilimnion zone for supplying upper layer clean water resulted in movement of turbidity plume that contained high phosphorus concentrations upward photic zone, and in turn increased algal growth in the lacustrine zone.

Sensing NO3-N and K Ions in Hydroponic Solution Using Ion-Selective Membranes (이온선택성 멤브레인을 이용한 양액 내 질산태 질소 및 칼륨 측정)

  • Kim, Won-Kyung;Park, Tu-San;Kim, Young-Joo;Roh, Mi-Young;Cho, Seong-In;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.343-349
    • /
    • 2010
  • Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of $NO_3$-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for $NO_3$-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination ($R^2$) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring $NO_3$-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination ($R^2$ > 0.97) between the levels of $NO_3$-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships ($R^2$ > 0.94) between the $NO_3$-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic $NO_3$-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.