• 제목/요약/키워드: Seismic effect

검색결과 1,572건 처리시간 0.025초

Analysis of settlements of space frame-shear wall-soil system under seismic forces

  • Jain, D.K.;Hora, M.S.
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1255-1276
    • /
    • 2015
  • The importance of considering soil-structure interaction effect in the analysis and design of RC frame buildings is increasingly recognized but still not penetrated to the grass root level owing to various complexities involved. It is well established fact that the soil-structure interaction effect considerably influence the design of multi-storey buildings subjected to lateral seismic loads. The shear walls are often provided in such buildings to increase the lateral stability to resist seismic lateral loads. In the present work, the linear soil-structure analysis of a G+5 storey RC shear wall building frame resting on isolated column footings and supported by deformable soil is presented. The finite element modelling and analysis is carried out using ANSYS software under normal loads as well as under seismic loads. Various load combinations are considered as per IS-1893 (Part-1):2002. The interaction analysis is carried out with and without shear wall to investigate the effect of inclusion of shear wall on the total and differential settlements in the footings due to deformations in the soil mass. The frame and soil mass both are considered to behave in linear elastic manner. It is observed that the soil-structure interaction effect causes significant total and differential settlements in the footings. Maximum total settlement in footings occurs under vertical loads and inner footings settle more than outer footings creating a saucer shaped settlement profile of the footings. Each combination of seismic loads causes maximum differential settlement in one or more footings. Presence of shear wall decreases pulling/pushing effect of seismic forces on footings resulting in more stability to the structures.

Nonlinear seismic response of a masonry arch bridge

  • Sayin, Erkut
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.483-494
    • /
    • 2016
  • Historical structures that function as a bridge from past to present are the cultural and social reflections of societies. Masonry bridges are one of the important historical structures. These bridges are vulnerable against to seismic action. In this study, linear and non-linear dynamic analyses of historical Nadir Bridge are assessed. The bridge is modelled with three dimensional finite elements. For the seismic effect, artificial acceleration records are generated considering the seismic characteristics of the region where the bridge is located. Seismic response of the bridge is investigated.

Foundation size effect on the efficiency of seismic base isolation using a layer of stone pebbles

  • Banovic, Ivan;Radnic, Jure;Grgic, Nikola
    • Earthquakes and Structures
    • /
    • 제19권2호
    • /
    • pp.103-117
    • /
    • 2020
  • The effect of the foundation size on the efficiency of seismic base isolation using a layer of stone pebbles is experimentally investigated. Four scaled models of buildings with different stiffnesses (from very stiff to soft) were tested, each with the so-called small and large foundation, and exposed to four different accelerograms (different predominant periods and durations). Tests were conducted so that the strains in the model remained elastic and afterwards the models were tested until collapse. Each model was tested for the case of the foundation being supported on a rigid base and on an aseismic layer. Compared to the smaller foundation, the larger foundation results in a reduced rocking effect, higher earthquake forces and lower bearing capacity of the tested models, with respectable efficiency (reduced strain/stress, displacement and increase of the ultimate bearing capacity of the model) for the considered seismic base isolation compared to the foundation on a rigid base.

능력스펙트럼을 이용한 지진격리교량의 내진성능평가 (Seismic performance evaluation using capacity spectrum method of bridge retrofitted with isolators)

  • 김민지;한경봉;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.129-134
    • /
    • 2002
  • The seismic performance evaluation and retrofit process are very important for old bridge. If the result is not appropriate, a retrofit process requires. Among the various retrofit methods, this paper selects a seismic isolator and evaluates a seismic performance of bridge. In case of applied seismic isolators to bridge, it proved that seismic capacity is increased by isolators A period of bridge is increased, and a seismic response is decreased. A method of evaluation is capacity spectrum method. By means of a graphical procedure, capacity spectrum estimates a performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. The objective of this study is to compare a seismic performance of a non-seismic designed bridge and seismic isolated bridge and to verify a effect of seismic isolator

  • PDF

이중 슬립마찰면을 이용한 면진장치의 면진성능평가 (Seismic Performance Evaluation of Seismic Isolation Device with Double Slip Friction Surface)

  • 손수원;권정호;김정곤;정용규;황은동
    • 한국재난정보학회 논문집
    • /
    • 제16권4호
    • /
    • pp.712-722
    • /
    • 2020
  • 연구목적: 최근 국내 규모 5.0이상의 지진으로 인한 피해 발생이 증가하고 있다. 지진이 발생하면 구조물 이외에도 내부설비, 전력기기 등에 피해를 주게 된다. 이에 본 논문에서는 지진으로 인한 배전반과 같은 전기기기의 피해를 저감시킬 수 있는 이중 슬립마찰면이 있는 면진장치를 개발하였으며, 이에 대한 면진성능을 평가하였다. 연구방법: 면진성능을 평가하기 위해 진동대 시험을 수행하였으며, 면진장치 유무에 따른 성능비교를 수행하였다. 다양한 주파수와 가속도 수준에 대한 응답가속도 및 변위를 비교하여 면진장치의 감쇠효과를 분석하였다. 연구결과: 시험결과, 면진장치가 설치되어 있는 경우가 면진장치가 설치되어 있지 않은 경우보다 가속도 증폭이 최대 42% 작았다. 이는 면진장치의 이중슬립마찰면 사이에서 발생한 변위가 지진에너지를 소산하는 역할을 하여 증폭에너지가 감소된 것으로 판단된다. 결론: 이중 슬립마찰면을 적용한 면진장치는 약진보다는 강진에서 지진감쇠효과가 더 컸으며, 주파수가 클수록 지진감쇠효과가 더 좋았다. 따라서, 배전반과 같은 전기기기에 적용하여 지진에너지를 감쇠하는 작용을 할 수 있을 것으로 판단된다.

SSI해석을 통한 압축전담 교량 내진보강공법 거동 특성 연구 (Behavior Characteristics of Compression-Only Bridge Seismic Reinforcement Method Using SSI Analysis)

  • 장유식;윤원섭;유광호
    • 한국산업융합학회 논문집
    • /
    • 제25권6_3호
    • /
    • pp.1231-1238
    • /
    • 2022
  • In this study, the reinforcement effect of the compression-only bridge seismic reinforcement method, which is mainly applied to old bridges, was studied through SSI analysis. As the analysis conditions, acceleration magnitudes of 0.1g, 0.15g, and 0.2 g were applied, and long-period and short-period seismic waves were applied. As a result of the analysis according to the assumed ground characteristics and structure size, the horizontal displacement at the reinforced section was reduced by about 9%, and the long-period seismic wave had a 95% larger displacement than the short-period seismic wave. In addition, an increase in acceleration of 0.1g resulted in a displacement of about 50%, and a large increase in displacement was observed in long-period seismic waves. As a result of the analysis, in the case of the compression-only bridge seismic reinforcement method, there was a reinforcing effect, so the field applicability was excellent.

Wave passage effect of seismic ground motions on the response of multiply supported structures

  • Zhang, Y.H.;Lin, J.H.;Williams, F.W.;Li, Q.S.
    • Structural Engineering and Mechanics
    • /
    • 제20권6호
    • /
    • pp.655-672
    • /
    • 2005
  • Seismic random responses due to the wave passage effect are extensively investigated by using the pseudo excitation method (PEM). Two examples are used. The first is very simple but also very informative, while the second is a realistic suspension bridge. Numerical results show that the seismic responses vary significantly with wave speed, especially for low velocity or large span. Such variations are not monotonic, especially for flexible structures. The contributions of the dynamic and quasi-static components depend heavily on the seismic wave velocity and the natural frequencies of structures. For the lower natural frequency cases, the dynamic component has significant effects on the dynamic responses of the structure, whereas the quasi-static component dominates for higher natural frequencies unless the wave speed is also high. It is concluded that if insufficient data on local seismic wave velocity is available, it is advisable to select several possible velocity values in the seismic analysis and to choose the most conservative of the results thus obtained as the basis for design.

조적채움벽 및 허리벽이 학교 건물 내진 성능에 미치는 영향에 대한 해석적 연구 (Analytical Study of the Effect of Full and Partial Masonry Infills on the Seismic Performance of School Buildings)

  • 김태완;민찬기
    • 한국지진공학회논문집
    • /
    • 제17권5호
    • /
    • pp.197-207
    • /
    • 2013
  • The seismic performance of school buildings has been a matter of common interest socially and academically. The structural system of the school buildings is representative of the domestic low-rise reinforced concrete moment resisting frames, which apply extensively infills in their masonry walls. The masonry infilled walls are divided into full masonry infill in the transverse direction and partial masonry infill in the longitudinal direction. The masonry infilled walls are usually not included in structural analysis during the design process, but affect significantly the seismic performance because they behave with surrounding frames simultaneously during earthquakes. Many researchers have studied the effect of the masonry infilled walls, but several issues have been missed such as the increase of asymmetry by adding the full masonry infill, the size of the mean strength of the full masonry infill, and short column effect by the partial masonry infill. The issues were analytically investigated and the results showed that they should be checked at least by nonlinear pushover analysis in the seismic performance evaluation process. The results also confirm the weakness of the guideline of Korean Educational Development Institute where the seismic performance is basically assessed without structural analysis.

원전 안전 1등급 기기의 유한요소 탄소성 시간이력 지진해석 결과에 미치는 가속도 가진 방법 내 기준선 조정의 영향에 대한 예비연구 (Preliminary Study on Effect of Baseline Correction in Acceleration Excitation Method on Finite Element Elastic-Plastic Time-History Seismic Analysis Results of Nuclear Safety Class I Components)

  • 김종성;박상혁
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.69-76
    • /
    • 2018
  • The paper presents preliminary investigation results for the effect of the baseline correction in the acceleration excitation method on finite element seismic analysis results (such as accumulated equivalent plastic strain, equivalent plastic strain considering cyclic plasticity, von Mises effective stress, etc) of nuclear safety Class I components. For investigation, finite element elastic-plastic time-history seismic analysis is performed for a surge line including a pressurizer lower head, a pressurizer surge nozzle, a surge piping, and a hot leg surge nozzle using the Chaboche hardening model. Analysis is performed for various seismic loading methods such as acceleration excitation methods with and without the baseline correction, and a displacement excitation method. Comparing finite element analysis results, the effect of the baseline correction is investigated. As a result of the investigation, it is identified that finite element analysis results using the three methods do not show significant difference.

깊게 파인 온통기초가 구조물의 수평방향 설계스펙트럼에 미치는 영향 (Effect of a Sunken Mat Foundation on the Horizontal Design Spectrum of a Structure)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제25권4호
    • /
    • pp.169-177
    • /
    • 2021
  • In this paper, horizontal seismic responses of a structure built on a sunken mat foundation were compared with those built on a solid embedded mat foundation to investigate the effect of a sunken mat foundation on the horizontal response of a structure. Seismic analyses of a structure laid on the embedded mat foundation were performed by utilizing a pseudo-3D finite element software of P3DASS. Three bedrock earthquake records downloaded from the Pacific Earthquake Engineering Research Center database were scaled to reproduce weak-moderate earthquakes. Weak, medium, and stiff soil layers were considered for the seismic analyses of the structure-foundation-soil system. Parametric studies were performed for foundation radius, foundation embedment depth, and shear wave velocity of a soil layer to investigate their effect on the seismic response spectrum. The study result showed that the design spectrum of a structure built on a sunken mat foundation was similar to that with a solid embedded mat foundation showing a slight difference due to almost the same seismic base motion beneath both embedded foundations.