• Title/Summary/Keyword: Seismic Hazard

Search Result 430, Processing Time 0.02 seconds

A Study on the Conventional Liquefaction Analysis and Application to Korean Liquefaction Hazard Zones (기존의 액상화 평가기법 밀 그 적용성에 관한 연구)

  • 박인준;신윤섭;최재순;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.431-438
    • /
    • 1999
  • An assessment of liquefaction potential is made in principle by comparing the shear stress induced by earthquake to the liquefaction strength of the soil. In this study, a modified method based on Seed and Idriss theory is developed for evaluating liquefaction potential. The shear stress in the ground can be evaluated with seismic response analysis and the liquefaction strength of the soil can be investigated by using cyclic triaxial tests. The cyclic triaxial tests are conducted in two different conditions in order to investigate the factors affecting liquefaction strength such as cyclic shear stress amplitude and relative density. And performance of the modified method in practical examples is demonstrated by applying it to liquefaction analysis of artificial zones with dimensions and material properties similar to those in a typical field. From the result, the modified method for assessing liquefaction potential can successfully evaluate the safety factor under moderate magnitude(M=6.5) of earthquake.

  • PDF

Development and application of pore pressure generation 모형 (과잉 간극 수압 모형 개발 및 적용)

  • Han, Jung-Woo;Lee, Seung-Chan;Park, Du-Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.546-550
    • /
    • 2007
  • High excess pore water pressure may develop when loose saturated sand is subjected to earthquake excitation, resulting in reduction in the shear strength and stiffness, and ultimately can result in liquefaction. It is very important to accurately assess the level of the pore pressure generation for seismic design and to perform effective stress analysis. A simple numerical 모형 is developed for estimating the development of pore water pressure due to seismic loading. The method only uses two parameters and the length of the accumulated shear strain. The accuracy of the proposed 모형 is verified through a series of laboratory test data. Comparisons show that the modified 모형 is an improvement over existing 모형s.

  • PDF

Information Geo-Technology for Seismic Analysis (내진해석을 고려한 정보화 시공)

  • Park, Inn-Joon;Kim, Soo-Il;Seo, Kyung-Bum;Park, Seong-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.92-104
    • /
    • 2005
  • Over the past decade, major advances have occurred in both understanding and practice with regard to assessment and mitigation of hazard area associated with seismically induced soil liquefaction. In this paper, assessment of liquefaction resistance of soil are reviewed from the recent researches. In addition site characteristics investigation methods and tests for seismic design and liquefaction analysis are reviewed. Finally, introduction and characteristics of remedial measures against soil liquefaction are reviewed briefly.

  • PDF

Generation of Design Spectrum Compatible Ground Motion in Time Domain (시간영역에서 생성되는 설계응답스펙트럼 맞춤형 지진파 생성)

  • Jeong, Chang-Gyun;Park, Du-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1250-1257
    • /
    • 2009
  • Due to the improvement of the seismic hazard analysis method and the design code, dynamic analysis method is widely used. To conduct dynamic analysis, various coefficients should be designated. The time history acceleration is one of the most essential factor. However, strong earthquake motion data from the outside of the country have been used to conduct dynamic analysis without considering of the ground motion parameters. In this study, the methodology to choose appropriate input motion is developed by using time domain design spectrum matching procedure. Two examples are applied to verify the methodology. The Result shows that the methodology satisfies seismic circumstances and the design code.

  • PDF

Effect of PSD Function on Linear Response and Inelastic Response of Single Degree of Freedom System (단자유도 시스템의 선형응답과 비탄성응답에 미치는 PSD함수의 영향)

  • Choi, Dong-Ho;Lee, Sang-Hoon;Kim, Yong-Sik;Koh, Jung-Hoon
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.257-259
    • /
    • 2008
  • Acceleration time history (ATH) used in the seismic analysis should envelop a target power spectral density (PSD) function in addition to the design response spectrum in order to have sufficient energy at each frequency for the purpose of ensuring adequate load. Even though design regulations require the ATH used in seismic analysis to meet a target PSD function, the reason that ATHs meet to a target PSD function is not described. Thus, artificial ATHs for high PSD function and artificial ATHs for low PSD function are generated. And then elastic and inelastic single-degree-of-freedom (SDOF) systems are loaded with these artificial time histories as the earthquake load. As a result, linear response and inelastic response of SDOF systems are affected by PSD function.

  • PDF

Comparison of Tunnel's Deformation by Spatially Variable Ground Motion (공간적으로 변이하는 지진파에 의한 터널의 변형 비교)

  • Kwak, Dong-Yeop;Ahn, Jae-Kwang;Park, Du-Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.265-268
    • /
    • 2008
  • The safety of a tunnel under seismic motion is most often evaluated by ovalling deformation of tunnel. This paper research about tunnel's longitudinal deformation. Because of spatial variation of seismic ground motion, the longitudinal structures like tunnel are likely to experience relative displacements along longitudinal direction. The spatially variable ground motion can be estimated by coherency function obtained empirically, and can be considered from different arrival times of ground motion. As a result of estimating tunnel's relative displacements at maximum curvature of tunnel, the displacements and curvatures estimated by coherency function affect the tunnel's safety more than different arrival times. However, if tunnel's displacements by coherency function superpose on displacements by different arrival times, the relative displacements and curvatures of tunnel will be more severe. Therefore, to estimate accurately tunnel's deformation in longitudinal direction has to consider both coherency and wave passage effects.

  • PDF

Evaluation of RC Building Structures Designed According to Eurocode 8 (Eurocode 8에 의해 설계도니 건축물의 평가)

  • 이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.297-304
    • /
    • 1999
  • the devastating earthquake which occurred in Turkey on August 187, 1999, reminds again us the necessity of the preparedness for the earthquake hazard. the level of earthquake engineering in Koran is still low due to the short period of the research and development in this field. Therefore the most efficient way of promoting our technology in this field is considered to collect the information on the state of the art and practice developed in the advanced countries in earthquake engineering and to analyze the advantages and disadvantages and then reflect these to the new seismic codes. for this purpose this study reviews the concept and main characteristics of Eurocode 8 and the findings of many researches that have been performed for the improvement of EC8. Finally the seismic performance evaluation of the building structures designed according to EC8. and the relevant recommendations are summarized.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a Full Scale Model of Wood House with Tiled Roof (기와집 실물크기 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof (초가집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Huh, Young-Chul;Jeon, Bong-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF