• Title/Summary/Keyword: Section function

Search Result 1,090, Processing Time 0.025 seconds

A Study on the Optimal Design of Prestressed Concrete Box Girder Bridges (프리스트레스트 콘크리트 박스 거더 교량의 최적설계에 관한 연구)

  • Noh, Kum-Rae;Yun, Hee-Taek;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.139-149
    • /
    • 2000
  • In the preliminary design stage of prestressed concrete (PSC) box girder bridges, the design factors decided by inexperience designer could heavily affect to the results of final design. There is a possibility that the design ends up with an excessively wasteful design. To achieve an economical design with preventing an excessive design, the optimal design technique has been developed using ADS optimal program and SPCFRAME in this study. The objective function for the optimal design problem is the material cost of box girders and constrained functions are constituted with design specifications and workability. The Sequential Unconstraint Minimization Technique (SUMT) is used for the optimal design in this study. We designed an uniform cross-section bridge and an ununiform cross-section bridge in the same design condition by optimal design technique developed in this study. Analyzing the results obtained for various tendon layouts, we suggest a standard tendon layout which gives the most effective structural behavior.

  • PDF

Heights on singular projective curves

  • Choi, Hyun-Joo
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • In this paper we show that for each divisor class c of degree zero on a projective curve C (not necessarily smooth), there exists a unique function $\hat{h}_c$ on C up to bounded functions. Section 1 contain basic definitions and a brief summary of classical results on Jacobians and heights. In section 2, we prove the existence of "canonical height" on a singular curves and in section 3 we prove the analogouse results on N$\acute{e}$ron functions for singular curves. This is a part of the author's doctorial thesis at Ewha Womens University under the guidence of professor Sung Sik Woo.g Sik Woo.

  • PDF

SPECTRAL INEQUALITIES OF THE LAPLACIAN ON A CURVED TUBE WITH VARYING CROSS SECTION

  • Mao, Jing;Hou, Lanbao
    • Communications of the Korean Mathematical Society
    • /
    • v.28 no.1
    • /
    • pp.177-181
    • /
    • 2013
  • In this note, we consider a curved tube with varying cross-section formed by rotating open bounded Euclidean domains with respect to a reference curve, and successfully give a lower bound to the threshold of the Laplacian on the tube, subject to Dirichlet boundary conditions on the surface and Neumann conditions at the ends of the tube. This generalizes the corresponding result in [1].

Tail Probability Approximations for the Ratio of the Independent Random Variables

  • Cho, Dae-Hyeon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.7 no.2
    • /
    • pp.189-201
    • /
    • 1996
  • In this paper, we study the saddlepoint approximations for the ratio of independent random variables. In Section 2, we derive the saddlepoint approximation to the density. And in Section 3, we derive two approximation formulae for the tail probability, one by following Daniels'(1987) method and the other by following Lugannani and Rice's (1980). In Section 4, we represent some numerical examples which show that the errors are small even for small sample size.

  • PDF

40-TFLOPS artificial intelligence processor with function-safe programmable many-cores for ISO26262 ASIL-D

  • Han, Jinho;Choi, Minseok;Kwon, Youngsu
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.468-479
    • /
    • 2020
  • The proposed AI processor architecture has high throughput for accelerating the neural network and reduces the external memory bandwidth required for processing the neural network. For achieving high throughput, the proposed super thread core (STC) includes 128 × 128 nano cores operating at the clock frequency of 1.2 GHz. The function-safe architecture is proposed for a fault-tolerance system such as an electronics system for autonomous cars. The general-purpose processor (GPP) core is integrated with STC for controlling the STC and processing the AI algorithm. It has a self-recovering cache and dynamic lockstep function. The function-safe design has proved the fault performance has ASIL D of ISO26262 standard fault tolerance levels. Therefore, the entire AI processor is fabricated via the 28-nm CMOS process as a prototype chip. Its peak computing performance is 40 TFLOPS at 1.2 GHz with the supply voltage of 1.1 V. The measured energy efficiency is 1.3 TOPS/W. A GPP for control with a function-safe design can have ISO26262 ASIL-D with the single-point fault-tolerance rate of 99.64%.

Evaluation of the Performance of One-way Drainage Filter by Field Test (시험시공을 통한 일방향 배수필터의 성능 평가)

  • Seo, Dong-Uk;Kim, Hyeon-Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.47-53
    • /
    • 2012
  • It is needed to install a one-way drainage filter to prevent a seepage from lake or river outside of embankment and to promote a drainage from a flood inside of embankment when dikes such as lake dike, river dike, etc are constructed. However, the results of research for one-way drainage filter are insufficient. Therefore, through the field test of one-way drainage filter, this study checked a function of one-way drainage filter with a test of performance. As a result of field test, water flow in dike was blocked in the interception direction of the section that one-way drainage filter was installed, but water passed to the flow allowance direction of the section. Therefore we confirmed the function of one-way drainage filter. Seepage quantity in the flow allowance direction of the one-way drainage filter section was low as 74.6~80.5 % than that in the section without installation of filter because of a reduction effect of seepage with filter. And seepage quantity of field test was low as 64.3~90.0 % than that in results of seepage analysis because the coefficient of permeability of embankment in field is different from the results of laboratory test. In the future, more study will be needed to solve several problems which are related to fix the filter on slide, durability of filter, etc.

Design Optimization of a Rapid Moving Body Structure for a Machining Center Using G.A. with Variable Penalty Function (가변 벌점함수 유전알고리즘을 이용한 금형가공센터 고속이송체 구조물의 최적설계)

  • 최영휴;차상민;김태형;박보선;최원선
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.504-509
    • /
    • 2003
  • In this paper, a multi-step optimization using a G.A.(Genetic Algorithm) with variable penalty function is introduced to the structural design optimization of a high speed machining center. The design problem, in this case, is to find out the best cross-section shapes and dimensions of structural members which minimize the static compliance, the dynamic compliance, and the weight of the machine structure simultaneously. The first step is the cross-section shape optimization, in which only the section members are selected to survive whose cross-section area have above a critical value. The second step is a static design optimization, in which the static compliance and the weight of the machine structure are minimized under some dimensional constraints and deflection limits. The third step is a dynamic design optimization, where the dynamic compliance and the structure weight are minimized under the same constraints as those of the second step. The proposed design optimization method was successful applied to the machining center structural design optimization. As a result, static and dynamic compliances were reduced to 16% and 53% respectively from the initial design, while the weight of the structure are also reduced slightly.

  • PDF

Evaluations of vital signs and echocardiographic left ventricular function after the constant rate infusion of lidocaine and/or ketamine in Beagle dogs

  • Kim, Ye-Won;Choi, Miru;Kim, Tae-Jun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.4
    • /
    • pp.215-219
    • /
    • 2015
  • Cardiopulmonary depression of long-term constant rate infusion (CRI) administration of multiple analgesic drugs is important, especially in critically ill dogs. Therefore, this study was conducted to evaluate the effects of lidocaine, ketamine or combined lidocaine-ketamine combination CRI treatment on vital signs and left ventricular (LV) function in healthy dogs. Six adult Beagle dogs were administered either ketamine (initial loading dose of 0.5 mg/kg followed by $10{\mu}g/kg/min$ CRI), lidocaine (initial loading dose of 2 mg/kg followed by 0.025 mg/kg/min CRI), or combined lidocaine-ketamine intravenously. Arterial blood pressure (BP), heart rate (HR), respiratory rate (RR), body temperature (BT) and echocardiographic LV dimensions were measured before administration of medications, immediately after administration of drugs, and then every 10 min for 2 h. There were no significant changes in HR, RR, BT and BP after the administration of either lidocaine CRI, ketamine CRI, or combined lidocaine and ketamine CRI. There were also no significant changes in LV dimensions and stroke volume. The results revealed that treatment with either lidocaine, ketamine or combined lidocaine-ketamine may not cause cardiopulmonary suppression in healthy dogs.

Use of separate single-tooth implant restorations to replace two or more consecutive posterior teeth: a prospective cohort study for up to 1 year

  • Kwon, Min-Jung;Yeo, In-Sung;Kim, Young-Kyun;Yi, Yang-Jin;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.2
    • /
    • pp.54-57
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the periodontal and prosthodontic complications of multiple freestanding implants in the posterior jaws for up to 1 year of function. MATERIALS AND METHODS. Eight patients received 20 implants posterior to canines. Two or more implants were consecutively inserted to each patient. Single crowns were delivered onto the implants. Marginal bone loss, implant mobility, probing depth, and screw loosening were examined to evaluate the clinical success of such restorations for maximum 1 year of functional loading. RESULTS. All the implants performed well during the observation period. Neither periodontal nor prosthodontic complications were found except a slight porcelain chipping. While the marginal bone level was on average 0.09 mm lower around the implant after 6 months of loading, it was 0.15 mm higher after 1 year. CONCLUSION. Within the limits of this investigation, separate single-tooth implant restorations to replace consecutive missing teeth may clinically function well in the posterior jaw.

A Study on the Eigen Ethnic Function and Mathematical Processing Method of Human Information (인적정보의 고유기능과 계량화 방안에 관한 연구)

  • 김홍재;서윤정
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.40
    • /
    • pp.329-339
    • /
    • 1996
  • This study presents the eigen ethnic function and mathematical processing method of human information. Human information can be definded as the overlap area taking the superposition property composed of intuition and sensory in stimulus/response (S/R) model, In S/R model, the intuition and sensory eigen ethnic function acts on the forming of perception. Perception process by the superposition property of intuition and sensory analogy to the basic neural network model. This analogy model extends to the analysis method. As an analysis method, optimal ratio number induced to the golden section ratio. Golden section ratio drived out by diverse source and implicated to the sensory and intuitive context such as beauty, harmony, optimality etc. This numerical orders can be applied to analysing the Perception process and extended to pursue the Potential human behavior, On the basic of proposed applying method, an illustrative mathematical examples are presented.

  • PDF