• Title/Summary/Keyword: Second-Order Distance

Search Result 314, Processing Time 0.033 seconds

Evaluation of Train Overhaul Maintenance Capacity for Rolling Stock Depot Using Computer Simulation Method (시뮬레이션 기법을 활용한 열차 차량기지의 중정비 검수 용량 평가)

  • Jang, Seong-Young;Jeon, Byoung-Hack;Lee, Won-Young;Yoo, Jae-Kyun
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.231-242
    • /
    • 2007
  • As railroad industry faces the new Renaissance era, effective and efficient maintenance methods for rolling stock operation are required with advanced railroad technology. All kinds of railroad systems such as high-speed long-distance train, metropolitan mass transit and light rail require systematic maintenance technology in order to maintain the safe railroad operation. Simulation models for regular operations of the example maintenance center are developed. In this study, standard maintenance procedures, layout, equipments, and number of workers of Siheung Metropolitan Railroad Maintenance Rolling Stock Depot are considered. The proposed simulation models are developed using simulation package ARENA. After simulation, four types of observations are analyzed. First, the bottleneck operation is identified. Second, the relationship between maintenance center size, number of workers and cycle time is analyzed. Third, the scheduling performances between PERT/CPM and Critical Chain Project Management(CCPM) are compared. Lastly, the simulation results according to worker's working coverage shows expanding the worker's coverage decreases the cycle time and increases throughput per train. However, workers are to be fully trained to do multiple skill work.

Yarn Segmentation from 3-D Voxel Data for Analysis of Textile Fabric Structure

  • Shinohara, Toshihiro;Takayama, Jun-ya;Ohyama, Shinji;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.877-881
    • /
    • 2005
  • In this paper, a novel method for analyzing a textile fabric structure is proposed to segment each yarn of the textile fabric from voxel data made out of its X-ray computed tomography (CT) images. In order to segment the each yarn, directions of fibers, of which yarn consists, are firstly estimated by correlating the voxel with a fiber model. Second, each fiber is reconstructed by clustering the voxel of the fiber using the estimated fiber direction as a similarity. Then, each yarn is reconstructed by clustering the reconstructed fibers using a distance which is newly defined as a dissimilarity. Consequently, each yarn of the textile fabric is segmented from the voxel data. The effectiveness of the proposed method is confirmed by experimentally applying the method to voxel data of a sample plain woven fabric, which is made of polyester two folded yarn. The each two folded yarn is correctly segmented by the proposed method.

  • PDF

A 0.25-$\mu\textrm{m}$ CMOS 1.6Gbps/pin 4-Level Transceiver Using Stub Series Terminated Logic Interface for High Bandwidth

  • Kim, Jin-Hyun;Kim, Woo-Seop;Kim, Suki
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.165-168
    • /
    • 2002
  • As the demand for higher data-rate chip-to-chip communication such as memory-to-controller, processor-to-processor increases, low cost high-speed serial links\ulcorner become more attractive. This paper describes a 0.25-fm CMOS 1.6Gbps/pin 4-level transceiver using Stub Series Terminated Logic for high Bandwidth. For multi-gigabit/second application, the data rate is limited by Inter-Symbol Interference (ISI) caused by channel low pass effects, process-limited on-chip clock frequency, and serial link distance. The proposed transceiver uses multi-level signaling (4-level Pulse Amplitude Modulation) using push-pull type, double data rate and flash sampling. To reduce Process-Voltage-Temperature Variation and ISI including data dependency skew, the proposed high-speed calibration circuits with voltage swing controller, data linearity controller and slew rate controller maintains desirable output waveform and makes less sensitive output. In order to detect successfully the transmitted 1.6Gbps/pin 4-level data, the receiver is designed as simultaneous type with a kick - back noise-isolated reference voltage line structure and a 3-stage Gate-Isolated sense amplifier. The transceiver, which was fabricated using a 0.25 fm CMOS process, performs data rate of 1.6 ~ 2.0 Gbps/pin with a 400MHB internal clock, Stub Series Terminated Logic ever in 2.25 ~ 2.75V supply voltage. and occupied 500 * 6001m of area.

  • PDF

An Analysis of Relation between Supply Criteria of Public Facilities and Residents' Satisfaction for the Community Revitalization in the Apartments (공동주택 내 커뮤니티 활성화를 위한 주민공동시설 설치기준과 주민 만족도와의 관계 분석)

  • Choi, Ki-Taek;Lee, Joo-Hyung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.19-28
    • /
    • 2011
  • This study examines the current status on the supply of community facilities based on the supply criteria of present welfare facilities. Analyzing satisfaction of residents about community facilities based on physical supply criteria. The study sets up the concept and proposed trend of the related studies and distinction through the examination of previous researches. Next, the present systematical supply criteria, was used to make indication in order to propose the promotion of improvement on supply criteria for community facilities. Multi dimensional analyzing system and the satisfaction level of the community facility was used to analyze the relationship between the two. The direction of policy improvement according to the analysis is as per the following. First, it is necessary to improve supply criteria of household to guarantee the minimal amount of space. Second, specification of the minimum distance of community facility to residential area in the complex is needed. Also, the presentation of bottom boundary line of the formation area size to expand the size up to minimal level of size is needed. Third, resident exercise facility supply criteria among the community facility supply criteria need to be improved from the number of household base to the size for each household base. Forth, resident resting facility criteria among the community facility supply criteria should be changed from the present criteria of one facility per five hundred households.

Transformation of Long Waves Propagating over Trench (트렌치 위를 통과하는 장파의 변형)

  • Jung, Tae-Hwa;Suh, Kyung-Duck;Cho, Yong-Sik;Park, Sung-Hyun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.228-236
    • /
    • 2007
  • An analytical solution for long waves propagating over an asymmetric trench is derived. The water depth inside the trench varies in proportion to a power of distance from the center of the trench. The mild-slope equation, governing equation, is transformed into second order ordinary differential equation with variable coefficients by using the long wave assumption and then the analytical solution is obtained by using the power series technique. The analytical solution is confirmed by comparison with the numerical solution. After calculating the analytical solution under various conditions, the results are analyzed.

Assessment of kinetics behavior of electrocoagulation process for the removal of suspended solids and metals from synthetic water

  • Singh, Hariraj;Mishra, Brijesh Kumar
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • Globalization, industrialization, mining, and uncontrolled population growth have fostered a shortage of potable water. Therefore, it has become imperative to understand an effective and reasonable water purification technique. A renewed interest in electrocoagulation (EC) has been spurred by the search for reliable, cost-effective, water-treatment processes. This paper has elucidated a technical approach for getting rid of heavy metals and total suspended solids (TSS) from synthetic water using an aluminum electrode. The effect of operational parameters, such as current density, inter-electrode distance, operating time, and pH, were studied and evaluated for maximum efficiency. This study corroborates the correlation between current density and removal efficiency. Neutral pH and a low electrode gap have been found to aid the efficacy of the EC setup. The outcome indicates that a maximum TSS removal efficiency of 76.6% occurred at a current density of $5.3mA/cm^2$ during a contact time of 30 min. In the case of heavy metals remediation, 40 min of process time exhibited extremely reduced rates of 99%, 59.2%, and 82.1%, for Cu, Cr, and Zn, respectively. Moreover, kinetic study has also demonstrated that pollutants removal follows first-and second-order model with current density and EC time being dependent.

Consonantal Production and V-to-V Coarticulation in Korean VCV Sequences (모음-자음-모음 연결에서 자음의 조음특성과 모음-모음 동시조음)

  • Shin, Ji-Young
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.55-81
    • /
    • 1997
  • In the present paper, V-to-V coarticulation in Korean VCV sequences is discussed, focusing on links between consonantal production and degree of V-to-V coarticulation. Temporal and spatial differences between three types of Korean alveolar stops (lax /t/. aspirated /$t^h$/ and thense /t'/) are examined from VCV sequences involving all possible combinations of three Korean unrounded vowels /a, i,/ based on spectrographic and electrographic data(two male speakers and one female speaker and one female speaker respectively). Closure duration and voice onset time (VOT) were measured from acoustic data. 'Total duration', which is defined as the sum of the closure duration and the VOT, was also calculated in order to see the temporal distance between two vowels in a VCV sequence. Differences in lingual-palatal contact pattern at the maximum contact (MC) point between the three types of stop were observed from EPG data. V-to-V coarticulation was investigated by measuring the offset or onset of the second formant (F2) of the target vowels from spectrograms. Two different dimensions of articulation, temporal and spatial, seem to playa role in determining the degree of V-to-V coarticulation. The degree of V-to-V anticipatory coarticulation is influenced by the spatial characteristics of the intervening consonant while the degree of carryover coarticulation is influenced by the temporal characteristics of the consonant.

  • PDF

Assessment of Gas Leakage for a 30-inch Ball Valve used for a Gas Pipeline (가스 파이프라인용 30인치 볼 밸브의 누설량 평가)

  • KIM, CHUL-KYU;LEE, SANG-MOON;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.230-235
    • /
    • 2016
  • The purpose of this study is to evaluate the gas leakage for a 30-inch ball valve. The ball valve was designed and manufactured for a natural gas transportation through a long-distance pipeline mainly installed in the permafrost region. The gas leakage assessment is based on the pressure testing criteria of international standards. Pressure conditions of the gas leakage test was employed 70 bar, 100 bar, and 110 bar. The amount of the gas leakage at each pressure condition was small and had a value under the pressure testing criteria, ISO 5208. Gas leakage with respect to the test pressure was predicted by the polynomial curve fitting using the experimental results. It is found that the gas leakage rate according to the pressure is proportion to a second order curve.

Add/drop Filter for CWDM Systems Using Side-coupled Long-period Fiber Gratings

  • Chan Florence Y. M.;Kim Myoung Jin;Lee Byeong Ha
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.135-139
    • /
    • 2005
  • We demonstrate a simple and effective wavelength-tunable add/drop filter suitable for coarse wavelength division multiplexing (CWDM) systems. The filter consists of two fibers in contact side by side, with identical long-period fiber gratings (LPG) in each fiber. The LPG couples the power in the fundamental core mode to one of the cladding modes, which is then coupled to the same order cladding mode in the other fiber through evanescent-field coupling between two fibers. Finally, the cladding mode in the second fiber is coupled to its core mode with the help of the other LPG. With an optimal longitudinal offset distance of 10 em, coupling efficiency as high as -1.68 dB and side lobes smaller than -24 dB were experimentally obtained. The experimental results agreed well with the theoretical ones. The operating wavelength of the proposed add/drop filter was tunable by varying the temperature. The temperature sensitivity was measured to be -0.43 nm/$^{\circ}C$.

A Real-Time Motion Recognition Algorithm for a Rehabilitation Service (재활 훈련 서비스를 위한 실시간 모션인식 알고리즘)

  • Choi, Wan;Lim, Cheol-Su;Kim, Tae-Young
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.9
    • /
    • pp.1143-1152
    • /
    • 2007
  • The objective of this paper is to develop the real time motion recognition method for the rehabilitation program of the people with physical disabilities. Using the infrared ray LED, this method gets the Teal time information of the user's motion and tells the difference between the information we get and the pre-defined information. In order to get the fast recognition and comparison, this method positions the specific coordinates of infrared ray LED in the pre-classified sector which keeps certain distance and angle from the point of origin. The result In our experiment shows the speed over 20 frames per second in every motion, and we are satisfied the rate for the recognition of the motions which is near 98%.

  • PDF