• 제목/요약/키워드: Screw-in effect

검색결과 368건 처리시간 0.03초

The effect of extrusion conditions on the acidic polysaccharide, ginsenoside contents and antioxidant properties of extruded Korean red ginseng

  • Gui, Ying;Ryu, Gi Hyung
    • Journal of Ginseng Research
    • /
    • 제37권2호
    • /
    • pp.219-226
    • /
    • 2013
  • This study was conducted to investigate the effect of extrusion conditions (moisture content 20% and 30%, screw speed 200 and 250 rpm, barrel temperature $115^{\circ}C$ and $130^{\circ}C$) on the acidic polysaccharide, ginsenoside contents and antioxidant properties of extruded Korean red ginseng (KRG). Extruded KRGs showed relatively higher amounts of acidic polysaccharide (6.80% to 9.34%) than non-extruded KRG (4.34%). Increased barrel temperature and screw speed significantly increased the content of acidic polysaccharide. The major ginsenosides (Rb1, Rb2, Rc, Rd, Re, Rf, Rg2s, Rg3s, Rh1, and Rg3r) of KRG increased through extrusion, while the ginsenoside (Rg1) decreased. The EX8 (moisture 30%, screw speed 250 rpm, and temperature $130^{\circ}C$) had more total phenolics and had a better scavenging effect on 2,2-diphenyl-1-picrylhydrazyl radicals than those of extruded KRG samples. The extrusion cooking showed a significant increase (6.8% to 20.9%) in reducing power. Increased barrel temperature significantly increased the values of reducing power, the highest value was 1.152 obtained from EX4 (feed moisture 20%, screw speed 250 rpm, and temperature $130^{\circ}C$). These results suggest that extrusion conditions can be optimized to retain the health promoting compounds in KRG products.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.

학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교 (Comparison of screw-in effect of three NiTi file systems used by undergraduates)

  • 오승희;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.477-484
    • /
    • 2006
  • 학생들이 사용한 세 가지 NiTi file systems (ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$)을 사용하여 성형한 모형 근관의 apical terminus width를 비교하여 flute angle 및 pitch 혹은 radial land가 screw-in effect에 미치는 효과를 알아보고자 하였다. NiTi file의 사용 경험이 없는 부산대학교 치과대학 4학년 학생 50명이 세 종류의 NiTi file systems- Pro File$^{(R)}$ (Dentsply Maillefer, Ballaigues, Switzerland), K3$^{TM}$ (SybronEndo, Glendora, France), Hero Shaper$^{\circledR}$(Micromega, Besancon, France)-을 사용하여 각 system으로 하나의 근관씩, 모두 150 개의 레진 블락 근관모형 (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland)을 16 : 1 감속 handpiece를 장착한 electric motor (Tecnika ATR, Pistola, Italy)를 사용하여 300 rpm의 속도에서 torque는 30 (Tecnikamotor setting value)으로 성형하였다. 스캐너로 근관 성형 전 후 이미지를 채득하여 중첩한 후 근단부의 최종 폭경을 측정하였다. 통계분석은 one-way ANOVA와 95% 신뢰도의 Scheffe's multiple range test로 사후 검증하였다. ProFile$^{(R)}$의 근관 성형 후 근단부의 폭이 Hero Shaper$^{(R)}$ and K3$^{TM}$에 비해 통계학적으로 유의하게 작았다. 본 연구의 결과에서 근단부의 과도한 확대가 variable pitch와 helical angle를 가진active file에 비해 con-stant pitch와 helical angle을 가짐에도 불구하고 radial land를 가진passive file에서 적게 나타났다. 이 결과로 추정해 볼 때, variable pitch와 helical angle보다는 근본적으로 radial land가 screw-in effect의 예방에 더 큰 역할을 하는 것으로 추정될 수 있다 따라서 NiTi file의 사용 경험이 없는 초심자의 경우 근단부 폭경의 유지능력이 좋은 ProFile$^{(R)}$의 사용이 추천된다.

현장인발시험을 통한 Screw Anchor Pile의 인발저항특성 (Pullout Capacity of Screw Anchor Piles Using Field Pull-out Tests)

  • 유충식;김대현
    • 한국지반공학회논문집
    • /
    • 제30권1호
    • /
    • pp.5-16
    • /
    • 2014
  • 본 논문에서는 현장인발재하시험을 통한 스크류 앵커 파일의 인발 저항 특성에 관한 연구내용을 제시하였다. 현장시험에서는 동일한 피치를 가지나 샤프트나 스크류 직경이 다른 스크류 앵커 파일에 대해 다양한 시공조건을 도출하고 이에 대한 시험을 수행하였다. 실험결과 스크류 앵커 파일은 스크류가 없는 파일에 비해 현저히 큰 인발저항력을 발휘하는 것으로 검토되었으며 시간경과 효과와 그라우팅 여부에 따른 검토 결과 일반 파일과 유사하게 시간경과에 따라 인발저항력이 증가하는 셋업효과와 그라우팅시 인발저항력 상승효과를 기대할 수 있는 것으로 분석되었다. 이와 아울러 기존의 헬리컬 파일의 인발저항력 산정식을 스크류 앵커 파일의 인발저항력 평가에 있어서의 적용성을 검토하였으며 현장인발재하 시험결과를 다양한 측면에서의 상관관계를 파악할 수 있도록 제시하고 연구결과의 실무적 관점에서의 검토 내용을 기술하였다.

지대주와 고정체의 체결방법에 따른 임플란트의 풀림거동에 관한 연구 (Effect of connection type on the screw loosening of implant system)

  • 최재민;전흥재;한종현;이수홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.486-491
    • /
    • 2004
  • A comparative study on the implant screw loosening under the initial clamping force and cyclic loads was conducted. The experiments were performed to evaluate the screw loosening behavior of the internal and external implant systems. It was found that the screw loosening torques of implant systems were significantly affected by the way how the abutment and fixture were connected due to the difference in the load transfer mechanism between abutment and fixture.

  • PDF

스크류 공기 압축기의 성능해석 (Performance Analysis of Screw Air Compressor)

  • 박동규;이관수
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.184-193
    • /
    • 2002
  • This study aims at the optimal design of the screw rotor and its performance analysis. The optimal design of the screw rotor's shape has been performed theoretically. Also, the performance analysis technique of an oil-injected screw air compressor is developed. The effect of internal leakage, heat exchange between air and oil, and flow resistance at suction and discharge ports are included in the performance analysis. Some numerical examples of the volumetric efficiency and adiabatic efficiency for sample rotors are demonstrated for various lobe combination, rotor wrap angles and L/D ratios.

원위 경비 인대 결합 고정 긴장도와 기간이 나사못 제거 후 이개 및 임상 증상에 미치는 영향 (The Impacts of Fixation Tightness and Duration on the Remnant Syndesmotic Widening and Clinical Symptom after Removal of Screws)

  • 배서영;손수인;성민규
    • 대한족부족관절학회지
    • /
    • 제17권4호
    • /
    • pp.264-271
    • /
    • 2013
  • Purpose: We aimed to analyze the effect of fixation tightness of the syndesmotic screw and its indwelling period on the recurrence of the syndesmosis widening after screw removal and the clinical outcomes. Materials and Methods: Forty consecutive patients with acute syndesmotic injury were retrospectively reviewed. The tibiofibular clear space is measured by digitalized measurement tool on serial radiographs. We analyzed the effect of time from trauma to fixation, syndesmotic screw indwelling duration, and fixation methods. Residual symptoms at the last follow up were evaluated. The student t-test, correlation test, and chi-square test were used for statistical analysis. Results: Eighteen ankles (45%) had recurrent syndesmosis widening (greater than 5% compared to the contralateral side). Seven patients had pain and five had limitation of motion in the ankle joint. Fixation tightness had significant effect on reducing the recurrence while the severity of the initial widening, time to fixation, and duration of fixation did not affect the outcome. Conclusion: Tight fixation of syndesmotic screw is essential for achieving final syndesmotic stability and reducing recurrence.

A study of size and frictional effect on the evolution of melting PartII: Twin screw extruder

  • Kim, D.S.;Lee, B.K.;Kim, H.S.;Lee, J.W.;C.G. Gogos
    • Korea-Australia Rheology Journal
    • /
    • 제13권2호
    • /
    • pp.89-95
    • /
    • 2001
  • Effects of particulate size and frictional characteristics were examined on the melting behavior of PP(polypropylene) in a twin screw extruder. Powder and pellet types of PP were used and each component was blended with PE(polyethylene) wax and clay, respectively. It was observed that small size particulates, 1.e. powder systems exhibit accelerated melting behavior; and it was also found that the abrasive auditive acts as an effective agent for fast melting of PP powder. Retardation of melting due to the reduced friction was observed in both types of PP, contrary to the result found in a batch mixer. The tendency observed in variation of torque and exit temperature was explained in terms of frictional effect and length of compacted region formed during evolution of melting.

  • PDF

단축 스크류 압축기에서 계량화부와 다이를 동시에 고려한 열 및 유동해석 (Simulation of Heat and Fluid Flow in the Single Screw Extruder with Coupling of the Metering Section and Die)

  • 윤정배;곽동성;김우승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.246-251
    • /
    • 2000
  • In the present study, the analysis on heat and fluid flow in the single screw extruder is carried out by simultaneously considering the metering section and the die. The finite difference method and the finite volume method are applied to the metering section and the die, respectively. The zonal method is used to couple the metering section and the die. To investigate the effect of die on the characteristics of heat and fluid flow in the single screw extruder, the pressure back flow is included in the analysis. The screw-tip rotation is also considered by employing the quasi 3-dimensional die model. The present results are compared with the numerical and experimental data available in the literatures.

  • PDF

치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향 (THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT)

  • 최진호;양재호;조원표;이재봉
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.432-442
    • /
    • 2006
  • Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.