THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT

치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향

  • Choi Jin-Ho (Department of Prosthodontics, Graduate School, Seoul National University) ;
  • Yang Jae-Ho (Department of Prosthodontics, Graduate School, Seoul National University) ;
  • Cho Won-Pyo (Department of Dentistry, College of Medicine, Konkuk University) ;
  • Lee Jai-Bong (Department of Prosthodontics, Graduate School, Seoul National University)
  • 최진호 (서울대학교 치과대학 치과보철학교실) ;
  • 양재호 (서울대학교 치과대학 치과보철학교실) ;
  • 조원표 (건국대학교 의과대학 치과학교실) ;
  • 이재봉 (서울대학교 치과대학 치과보철학교실)
  • Published : 2006.08.01

Abstract

Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.

Keywords

References

  1. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983; 50: 399-410 https://doi.org/10.1016/S0022-3913(83)80101-2
  2. Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of edentulous jaw. Int J Oral Surg 1981;10:387-416 https://doi.org/10.1016/S0300-9785(81)80077-4
  3. Tolman DE, Keller EE. Endosseous implant placement immediately following dental extraction and alveoloplasty : preliminary report with 6-year follow-up. Int J Oral Maxillofac Implants 1991 ;6:24-8
  4. Jemt T, Lekholm U. Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995; 10: 303-11
  5. Zarb GA, Jansson T, Jemt T. Other prosthodontic applications. Quintessence Int 1985: 283-292
  6. Burguette RL, John RB, King T, Patterson EA. Tightening characteristic for screwed joint in osseointegrated dental implant. J Prosthet Dent 1994;71(6) :592-599 https://doi.org/10.1016/0022-3913(94)90443-X
  7. Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants. The Toronto study. Part III : Problem and complications encountered. J Prosthet Dent 1990;64:185-194 https://doi.org/10.1016/0022-3913(90)90177-E
  8. Misch CE. Contemporary implant dentistry, St.Louis: Mosby; 1993
  9. Jemt T, Laney WR, Harris D, Henry PJ, Krogh P, Polizzi G. Osseointegrated implants for single tooth replacement : A 1year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36
  10. Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses suppoted by Branemark implants in edentulous jaws : A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276
  11. Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup, Int J Oral Maxillofac Implants 1992;7:40-44
  12. McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin North Am 1998;42:71-89
  13. Haack JE, Sakaguchi RL, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995; 10: 529-536
  14. Winkler S, Ring K, Ring JD, Boberick KG. Implant screw mechanics and settling effect : overview. J Oral Implantol 2003; 29(5) :242-5 https://doi.org/10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2
  15. Bickford JH. An introduction to the design and behavior of bolted joints. New York; Marcel Dekker, 1981
  16. Shigley JE, Mischke CR. Standard Handbook of Machine Designs. New York ; McGraw-Hill; 1986
  17. Hagiwara M, Chashi N. New tightening technique for threaded fasteners. Materials and engineering proceedings of the international offshore mechanics and arctic engineering symposium. New York; American Society of mechanical Engineers; 1992
  18. Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992; 7: 353-359
  19. Bakaeen LG, Winkler S, Neff PA. The effect of implant diameter. restoration design. and occlusal table variations on screw loosening of posterior single- tooth implant restorations. J Oral Implantol 2001 ;27:63-72 https://doi.org/10.1563/1548-1336(2001)027<0063:TEOIDR>2.3.CO;2
  20. Siamos G. Winkler S, Boberick KG. The relationship between implant preload and screw loosening on implant-supported restorations. J Oral Implantol 2002;28: 67-73 https://doi.org/10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2
  21. Luterbacher S, Fourmousis I, Lang NP, Bragger U. Fractured prosthetic abutments in osseointegrated implants : a technical complication to cope with. Clin Oral Implants Res 2000;11(2):163-170 https://doi.org/10.1034/j.1600-0501.2000.110209.x
  22. Weiss EI, Kozak D, Gross MD. Effect ofrepeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000 ;84(2): 194-9 https://doi.org/10.1067/mpr.2000.108069
  23. Sopwith DG. The distribution of load in screw threads. Proc Inst Mech Eng 1948; 159:373-383
  24. Naert I, Quirynen M, van Steenberghe D, Darius PA. Six year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992:67:236-4 https://doi.org/10.1016/0022-3913(92)90461-I
  25. Jaarda MJ, Razzoog ME, Gratton DG. Comparison of 'look-alike' implant prosthetic retaining screws. J Prosthodontics 1995;4:23-27 https://doi.org/10.1111/j.1532-849X.1995.tb00310.x
  26. Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 1992;7:26-33
  27. Weinberg LA, Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Proshtodont 1995; 8:421-33
  28. Binon P, Franz, Brunski J, Gulbransen H. The role of screws in implant systems. Int J Oral Maxillofac Implants.1994;9(supplement) :48
  29. Binon P. Implants and components: Entering the new millennium. Int J Oral Maxillofac Implants 2000; 15: 76-94
  30. Peterson RE. Stress Concentration Factors. New York: John Wiley & Sons; 1974
  31. Tzenakis GK, Nagy WW, Fournelle RA, Dhuru VB. The effect of repeated torque and salivary contamination on the preload of slotted gold prosthetic screws J Prosthet Dent 2002;88(2):183-191 https://doi.org/10.1067/mpr.2002.127604
  32. Byrne D, Jacobs S, O'Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont 2006; 15(3): 164-171 https://doi.org/10.1111/j.1532-849X.2006.00096.x