소형금속판에 고정나사의 삽입시 drilling의 위치 및 각도에 따른 시편의 이동량에 대한 효과 (THE EFFECT OF LOCATION AND ANGLE OF DRILLING ON THE CHANGES OF THE DISTANCE BETWEEN TWO BLOCK SPECIMENS DURING SCREWING ON MINIPLATE FIXATION)

  • 오현철;안진석;구홍;국민석;박홍주;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권3호
    • /
    • pp.213-221
    • /
    • 2006
  • Purpose This study was aimed to evaluate the effect of the location and angle of drilling on the changes of the distance between the two block specimens. Materials and methods In experimental group 1, the screw holes were prepared by drilling in the distal portion of compression part of the plate at $90^{\circ}$. In experimental group 2, the drilling was performed at an angle of $30^{\circ}$ proximal to the miniplate, and in experimental group 3, at $30^{\circ}$ distal respectively. In control group, the drilling was performed to the center of hole at $90^{\circ}$. The fixation screw length was 5 mm, 7 mm, and 9 mm in all groups. The results were as follows. Results 1. In control group, the mean changes between two specimens were 0.01 mm, 0.02 mm, and 0.00 mm in 5 mm, 7 mm, and 9 mm screws respectively. 2. In experimental group 1, the compression part was moved toward the retention part. The range of mean changes were from -0.39 mm to -0.43 mm. 3. In experimental group 2, the compression part was moved toward the retention part. The range of mean changes were from -0.51 mm to -0.56 mm. 4. In experimental group 3, the compression part was moved apart from the retention part and the range of mean changes were from 0.55 mm to 0.56 mm. 5. The changes were significantly different between all groups(p<0.01). Conclusion These results suggest that 0.4$\sim$0.5 mm of compressive effect can be achieved by drilling on the distal area of the screw hole at an angle of $90^{\circ}$ and by the proximal angulation to the miniplate, and the gap between specimens can be increased by distal angulation to the miniplate during drilling.

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

정중구개 봉합선 급속확장시 구강 및 비강 변화에 관한 단층 두부방사선적 연구 (A TOMOGRAPHIC STUDY ON ORO-NASAL DIMENSIONAL CHANGES FOLLOWING RAPID PALATAL EXPANSION)

  • 황인준;박영철
    • 대한치과교정학회지
    • /
    • 제21권3호
    • /
    • pp.657-670
    • /
    • 1991
  • It was said that early rapid palatal expansion was the treatment of choice in case of maxillary constriction with posterior crossbite. The author tried to assess dimensional changes of nasal and oral cavity before rapid palatal expansion and over 4 months of retention by use of three coronal tomograms through the incisal, molar, and maxillary tuberosity areas. The subjects of this study were consisted of 9 boys and 11 girls ranging from 11 to 13 years old. The results were as follows: 1. A mean change in maxillary first molar width was 3.68mm and a mean change in nasal cavity width was 2.26mm after 6.70mm expansion by Hyrax-type screw and over 4 months of retention tomographically in molar cut. 2. A change in nasal cavity width tomographically showed in order of molar cut, incisal cut, maxillary tuberosity cut respectively. 3. There was no correlation between changes in oral cavity width and nasal cavity width.

  • PDF

임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석 (3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs)

  • 이성천;김석규
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.365-375
    • /
    • 2009
  • 연구목적: 임플란트 보철물의 유지형태 중 나사 및 시멘트 혼합 유지형의 경우 나사 풀림력 등에 영향을 주는 임플란트 구성 성분의 응력에 관한 연구가 부족하였다. 임플란트 상부 보철물의 유지형태, 즉, 시멘트 유지와 나사 유지, 그리고 이 두 가지 유지형태가 서로 연결된 혼합형의 임플란트 보철물의 응력분산의 특징들을 3차원 유한요소분석법을 이용하여 비교하고자 하였다. 연구재료 및 방법: 하악골에서 제1소구치 부위와 제1대구치 부위에 2개의 임플란트 (SS II, Osstem Co. Ltd., Seoul, Korea)를 식립한 가상의 3본 계속가공의치를 모델화하였다. 지대주 종류와 그 위치에 따라, 4가지 모형 군으로 나누어 실험하였다. 모형 1은제1대구치와 제1소구치 각각의 고정체에 모두 동일한 시멘트 유지형 지대주인 Comocta abutment (Osstem Co. Ltd) 를 장착하여 3본 계속가공의치를 합착시킨 경우이고, 모형 2는 제1대구치와 제1소구치 각각의 고정체에 모두 나사 유지형 지대주인 Octa abutment (Osstem Co. Ltd) 를 장착하여 3본 계속가공의치를 나사로 고정시킨 경우이며, 모형 3은 제1대구치의 고정체에는 시멘트 유지형 지대주인 Comocta abutment를 장착하고, 제1소구치에는 나사 유지형 지대주인 Octa abutment를 장착한 후 3본 계속가공의치를 각각 시멘트 합착 및 나사로 고정시킨 경우이다. 그리고 모형 4는 모형 3에서 각각 제1대구치 및 제1소구치의 지대주를 맞바꾼 후 3본 계속가공의치를 나사 및 시멘트로 고정시킨 경우로 나누었다. 평균저작압인 하중을 대구치 565 N과 소구치 288 N의 힘으로 설정하고 수직방향으로 중심와와 협측 교두정에, 그리고 $30^{\circ}$ 경사 하중을 협측 교두정 부위에 준 다음 골, 고정체, 지대주, 그리고 지대주 나사 등에 나타나는 von-Mises stress 양상을 평가하였다. 결과: 네 가지 모형 중 나사 유지형 지대주인 Octa abutment를 제1대구치와 제1소구치 부위에 사용한 모형 2가 전반적으로 가장 낮은 안정적인 응력 분포를 보였다. 네 가지 모형 모두 피질골 및 고정체에 미치는 응력 크기 및 분포는 거의 유사하며, 치조골에 작용하는 응력은 하중의 종류와 상관없이 주로 피질골에 집중되었다. 지대주, 지대주 나사, 그리고 보철물 나사 등에 미치는 응력 크기나 분포는 모형에 관계없이 나사 유지형인 경우가 시멘트 유지형인 경우에 비해 낮은 안정적인 값을 보였다. 제1대구치와 제1소구치의 상부 구조물의 차이에 의한 교호작용 (reciprocal action)은 상대적으로 약하였다. 모든 부위에서 중앙 수 직하중, 교두정 수직하중, 그리고 교두정 경사하중의 순으로 응력값이 증가하였다. 결론: 본 유한 요소실험의 한계내에서 나사 및 시멘트 혼합 유지형의 임플란트 보철물은 시멘트 유지형만 사용하는 경우와 비교하여 주위에 더 큰 응력을 나타내지는 않았다. 이상적인 passive fit의 가정하에서 나사 유지형의 임플란트 보철물이 본체와 주위에 가장 작은 응력을 나타내었다.

Polymerization of Sugar by Extrusion

  • Hwang, Jae-Kwan;Kim, Chul-Jin;Chong-Tai, Kim
    • Preventive Nutrition and Food Science
    • /
    • 제2권4호
    • /
    • pp.296-300
    • /
    • 1997
  • Glucose syrup and lactose, mixed with citric acid as a polymerizing catalyst, was processed using twin screw extruder, in which 40 of L/D(length/diameter) ratio was designed to provide sufficient retention in extruder for polymerization of sugars. The polymerization yields of glucose syrup were 36.90%, 55.44% and 77.10% at 160, 180 and 20$0^{\circ}C$, respectively, while those of lactose were 26.45%, 38.16% and 45.86% at the same temperatures. Gel permeation chromatography exhibited that the higher molecular weight fractions were increased with extrusion temperature, which also led to increasing hydrodynamic intrinsic viscosity. Both uco-oligosaccharides and lacto-oligosaccharides produced by extrusion of glucose syrup and lactose were stable for thermal treatments over a wide range of pH3.0~11.0. In addition, $\alpha$-amylase and amyloglucosidase treatment of gluco-oligosaccharides did not affect the solution viscosity, indicating the random linkage rather than $\alpha$-1, 4 linkages of glucose and thus the potential applications as a dietary fiber. In this research it was clearly observed that twin screw extrusion can be successfully utilized to produce gluco-oligosaccharides and lacto-oligosaccharides rapidly and continuously in conjunction with selective control of polymerized composition.

  • PDF

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

완전 무치악 환자에서 자유 착탈가능 임플란트 지대주를 이용한 임플란트 융합 국소의치 수복증례 (Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report)

  • 오유경;정창모;윤미정;이소현;이현종;허중보
    • 대한치과보철학회지
    • /
    • 제58권1호
    • /
    • pp.58-66
    • /
    • 2020
  • 완전무치악환자의 보철 치료를 위한 방법 중에서 임플란트 지지 상부보철물을 서베이드 금관의 형태로 제작하여 국소의치의 지대치로 활용하는 임플란트 융합 국소의치(Implant-Assisted Removable Partial Denture, IARPD) 치료가 많은 관심을 받고 있다. 이 치료 방법에서 지대치로 사용되는 임플란트 상부보철물은 유지 형태에 따라 전통적으로 나사 유지형과 시멘트 유지형으로 분류되며 각각 장, 단점이 존재한다. 시멘트 제거, 수리의 어려움, 나사구멍(screw hole)으로 인한 비심미성 등을 극복하기 위해 최근에 새로운 유지 형태의 임플란트 보철 시스템인 EZ crown system (Samwon DMP, Yangsan, Korea)이 소개되었다. 이 시스템은 fixture에 체결되는 나사 일체형의 특수 abutment와 니켈-티타늄 스프링과 지르코니아 볼이 포함된 cylinder 구조물을 microlocking 방식으로 연결하여 유지력을 얻는다. 이번 증례의 환자는 하악 피개의치의 지대치가 발거되어 새로운 의치를 제작하고 싶다는 주소로 내원하였다. 환자 맞춤형의 진단 과정을 통해 전방부의 임플란트 서베이드 보철물을 이용한 임플란트 융합 국소의치를 계획하였다. 특히, 전통적인 방식의 임플란트 상부 보철물들의 단점을 보완하고자 EZ crown system을 적용한 임플란트 서베이드 보철물을 제작하여 기능적, 심미적으로 양호한 결과를 얻을 수 있었기에 이를 보고하는 바이다.

유성견 급속 구개확장시 정중구개봉합부 및 치아주위 조직 변화에 관한 조직형태학적 및 면역조직화학적 연구 (Changes in midpalatal suture area and adjacent periodontal tissues of individual tooth following rapid palatal expansion in young adult dogs ; Histomorphologic and immunohistochemical study)

  • 이주영;이진우;차경석
    • 대한치과교정학회지
    • /
    • 제30권3호
    • /
    • pp.317-333
    • /
    • 2000
  • 급속 구개확장은 정중구개봉합을 이개하기 위하여 강한 힘을 치아에 가하게 된다. 확장후 정중구개봉합부에 존재하는 골모세포와 섬유모세포의 증식 활성도를 측정하여 정중구개확장이 생리적으로 진행되는지를 확인하고, 이때 개개 치아의 치주조직에서 나타나는 변화를 조사하기 위하여 약 10개월된 유성견 10마리를 대상으로 상악 제2소구치와 제1대구치에 Hyrak screw를 장착하였다. 실험동물은 대조군 1마리, 1주 확장한 군 3마리, 2주 확장한 군 3마리, 2주 확장후 2주 보정한 군 3마리로 구분하여, Screw를 1일 1/4회전시켜 확장하였고, 제2소구치, 제3소구치, 그리고 제 1대구치 부위의 정중구개봉합부와 치주조직을 절취하여 Soft X-ray로 관찰하고, 형태학적 및 면역조직화학적 변화를 광학현미경으로, 그리고 골개조를 편광현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 편광현미경 소견에서는 대조군에 비하여 1주 확장군의 봉합부에서 골 형성과 흡수가 크게 증가되었으며, 2주 확장군에서 약간 감소를 보이다가, 보정군에서는 석회화가 크게 진행되었다. 2. 면역조직화학적 연구에서는 대조군에 비하여 1주 확장군의 봉합부에서 골모세포가 PCNA(Proliferating Cell Nuclear Antigen)에, 미분화 섬유모세포가 EGF(Epidermal Growth Factor)에 약간 증가된 양성 반응을 보였으며 EGF에 대한 골모세포의 반응은 낮았다. 2주 확장군에서는 섬유아세포와 골모세포에서 PCNA와 EGF에 대한 양성반응이 증가되었다. 보정군에서는 이들 PCNA와 EGF에 양성반응을 나타내는 세포들이 구개돌기 골단 주변에 집중되었다. 3. 확장기간 중 봉합부 주변에서 광범위한 골 흡수와 골형성을 동반한 골개조가 일어났으며, 보정군에서는 다소 감소하였다. 2주 확장군과 보정군의 제3소구치 와 제1대구치의 치근단에서 백악질 형성과 흡수가 나타났으며, 제1대구치의 협측 치경부에서 광범위한 초자양 변성대가 나타났다. 4. Soft X-ray소견에서 1주 확장군은 대조군에 비교하여 봉합부위의 여러부분에서 미세 파절과 저석회화된 결손부위를 보였다. 대조군과 보정군 사이 에는 정중구개봉합부의 석회화 정도에 별 차이 가 없었다. 2주 확장군과 보정군에서 제3소구치와 제1대구치는 협측으로 경사되는 경향을 보였다.

  • PDF

Extrusion Cooking처리가 미당(米糖)에 함유하는 비타민의 잔존율에 미치는 영향 (Vitamin Retention in Rice Bran during Extrusion Cooking)

  • 김복남;최홍식;이규한
    • 한국식품과학회지
    • /
    • 제18권3호
    • /
    • pp.187-191
    • /
    • 1986
  • 미강(쌀겨)의 유지, 단백질 및 vitamin을 효과적으로 활용하기 위한 연구로서, 미강(수분함량 9.5% 및 15. 6%)을 extrusion cooking 처리장치로서 주어진 specific dower consumption ($42.1{\sim}67.9w/kg$범위)extrusion temperature ($99{\sim}135^{\circ}C$범위) 조건에서 extrusion cooking하여, 미강이 함유하고 있는 thiamine, riboflavin 및 niacin의 잔동율에 관하여 연구한 결과를 요약하면 다음과 같다. 미강에 함유되어 있는 thiamine, riboflavin 및 niacin의 잔존율은 extrusion cooking 처리시의 원료수분함량에 영향을 받으며, 수분함량이 많으면 적은 specific power consumption 및 낮은 extrusion temperature에서도 이들 vitamin의 파괴현상이 더 일어난다. 동등한 수분함량의 원료미강을 extrusion cooking 처리할 때, specific power consumption이 커질수록 그리고 extrusion temperature가 높을수록 이들 vitamin의 잔존율이 저하된다. 그리고 전extrusion cooking 조건에서 thiamine은 $89.9{\sim}97.0%$, riboflavin은 $83.4{\sim}97.3%$, niacin은 94.0%. riboflavin은 $83.4%{\sim}97.3%$ 그리고 niacin은 $94.0{\sim}97.7%$의 잔존율을 보이므로써, 전반적으로 순간고온압출공정인 extrusion cooking이. 가열처리보다 높은 vitamin 잔존율을 나타내고 있었다.

  • PDF

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.