• Title/Summary/Keyword: Screening ultrasound

Search Result 82, Processing Time 0.028 seconds

What Do Korean Women Know and Want to Know about Thyroid Cancer? A Qualitative Study

  • Lee, Bomyee;Park, Jae Young;Shin, Hye Young;Park, Sang Hee;Choi, Eun-Bi;Yoo, Jisu;Choi, Kui Son;Jun, Jae Kwan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2901-2907
    • /
    • 2016
  • Background: Despite increasing debate about overdiagnosis and overtreatment of thyroid cancer in Korea, information to guide decisions on whether or not to undergo screening for and treatment of abnormal lesions of the thyroid is lacking. Moreover, studies have yet to outline what lay people know and want to know about thyroid cancer. The primary aim of this study was to explore general awareness of thyroid cancer among Korean women, their sources of information, and their satisfaction with the information they are provided. The secondary aim was to investigate information needs about thyroid cancer. Materials and Methods: A qualitative study using focus group interviews was conducted. Twenty-nine women were divided into four groups: (1) participants who had never undergone thyroid ultrasound screening; (2) those who had undergone screening, (3) those who continued to undergo regular check-ups with ultrasonography for benign nodules of the thyroid; and (4) participants who had undergone surgery for thyroid cancer. Results: A widespread lack of awareness of information on thyroid cancer was noted among participants in groups 1 and 2 who were not well aware of thyroid cancer and generally recognized it as a 'good cancer'. Surprisingly, instead of doctors and medical personnel, most participants reported obtaining information from acquaintances and media outlets. Moreover, most participants described dissatisfaction with their experience with screening and a lack of explanation on treatment and test results from medical personnel. Conclusions: Women in Korea seek reliable information on thyroid cancer that could help them to better understand the disease and make informed decisions regarding screening and treatment. More effort is needed from medical personnel to communicate the implications of thyroid cancer, screening results, and treatments thereof to lay people.

A Study on the Effectiveness of Screening for Selective Breast Cancer Using Digital Mammography Centered on General Hospital (디지털 유방촬영술을 이용한 선별적 유방암 검진의 효용성에 대한 연구(2차 병원을 중심으로))

  • Kim, Hyeon-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.147-152
    • /
    • 2021
  • This study is a retrospective analysis of the results of tests at three general hospitals in Busan that perform mammography using digital mammography devices. There were 5,320 people in the study, and the results of their breast cancer screening were analyzed to verify the efficacy of breast cancer screening for digital mammography. The average age of patients who performed breast cancer screening was 57.7 years (range 30 to 87 years), and the cancer detection rate was 26, with 4.6 cases per 1,000 people. According to the cancer detection rate by risk factor in patients who conducted breast cancer screening, breast cancer was found in patients without underlying diseases more than in patients with underlying diseases. Additional ultrasound examinations show that the gastronomic rate identified is 3.6%, which is relatively very low compared to that of the Film-Screen system.

The Results of Ultrasound Examination of the Elbow in Middle School Baseball Players (중학교 야구선수에서 시행한 주관절 초음파 검사의 결과)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Jin, Hong Ki
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.89-97
    • /
    • 2014
  • Purpose: To evaluate the ultrasonographic findings of the elbows on group screening of middle school baseball players. Materials and Methods: Ninety-three players (age: 12-15, mean 13.5 years) of four middle school baseball team were evaluated with bilateral elbow ultrasonographies in the field regardless of elbow pain. Medial and anterolateral ultrasound examination of the both elbow were performed in the field to detect any abnormalities including medial epicondylar separation or fragmentation and capitellar osteochondritis dissecans respectively. We analyzed the relationship among elbow pain, physical findings and sonographic abnormalities and the differences of sonographic abnormalities between pitchers and fielders. Results: Thirty-six of 93 (39%) players had sonographic abnormalities of elbow in dominant arm, 30 with medial epicondylar apophyseal separation or fragmentation, 2 with osteochondritis dissecans, 4 with both lesions. Twenty-nine of 37 (78%) players with elbow pain had sonographic abnormalities. On physical examination, players with medial epicondylar abnormalities had medial epicondylar tenderness (59%) and pain on valgus stress test (52%), and 5 of 6 (83%) players with osteochondritis dissecans showed flexion contracture more than $5^{\circ}$. The incidence of medial epicondylar abnormalities between pitchers and fielders was statistically not significant but osteochondritis dissecans was more prevalent in pitchers (p<0.05). Conclusion: Elbow sonography is a simple and useful screening tool in the field and also effective for early detection of medial epicondylar abnormalities or osteochondritis dissecans that could be the main causes of elbow pain in adolescent baseball players.

  • PDF

Analysis of Mammographic Breast Density in a Group of Screening Chinese Women and Breast Cancer Patients

  • Liu, Jing;Liu, Pei-Fang;Li, Jun-Nan;Qing, Chun;Ji, Yu;Hao, Xi-Shan;Zhang, Xue-Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6411-6414
    • /
    • 2014
  • Background: A dense breast not only reduces the sensitivity of mammography but also is a moderate independent risk factor for breast cancer. The percentage of Western women with fat breast tissue is higher aged 40 years or older. To a certain extent, mammography as a first choice of screening imaging method for Western women of this group is reasonable. Hitherto, the frequency and age distribution of mammographic breast density patterns among Chinese women had not been characterized. The purpose of this study was to investigate the frequency and age distribution of mammographic breast density patterns among a group of Chinese screening women and breast cancer patients in order to provide useful information for age-specific guidelines for breast cancer screening in Chinese women. Methods: A retrospective review of a total of 3,394 screening women between August and December 2009 and 2,527 breast cancer patients between July 2011 and June 2012 was conducted. Descriptive analyses were used to examine the association between age and breast density. The significance of differences of breast density between the screening women and the breast cancer patients was examined using nonparametric tests. Results: There was a significant inverse relationship between age and breast density overall (r=-0.37, p< 0.01). Breast density of the breast cancer patients in the subgroups of 40-49 years old was greater compared with that of the screening women, the same in those aged 50-54 years and in those 55 years old or older, less than in the screening group. Conclusions: With regard to the Chinese women younger than 55 years old, the diagnostic efficiency of breast cancer screening imaging examinations may be potentially improved by combining screening mammography with ultrasound.

Health screening upper abdominal USG results of the Multiple subjects Regression Analysis of the Risk Factors Associated with Fatty Liver Build Up (건강검진 수검자의 상복부초음파에서 진단된 지방간과 임상학적 검사 결과의 상관성 분석)

  • Choi, Kwan Yong;Yoo, Se Jong;Seon, Jong Ryoul;Lee, Won Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2014
  • The purpose of this report is to discuss the obtained findings gathered from ultrasound screenings of the liver. After running diagnostic tests health, screens were then conducted to analyze and compare the gained results. This data was then charted and used to strengthen our theorized hypothesis. From January 2013 to June 2013 a recorded 2906 people over the age of 20 visited Health Promotion Centers in various areas throughout Daejeon. Of those 2906 participants 1789 underwent screenings for abdominal ultrasonography; these participants as well as their ultrasound results were used as the bases of our study. For the establishment of our baseline and the comparison of our results, we gathered case-controlled studies from various reputable sources. Both the control and the experimental groups were tested to measure the following liver enzymes (AST, ALT, r-GTP, ALP, and etc.). Kidney functions were measured as well enzymes such as BUN, Creatinine, and Uric Acids levels were analyzed and recorded to see if any relationships existed between the levels documented in the liver and those in the kidneys. It was shown that the two primary causes of fat build up within the liver were significantly connected to obesity BMI(OR=4.14) and waist circumference(OR=3.88).

Design of Standard Value Intracranial Translucency of Fetus in Early Pregnancy Using Ultrasound (초음파를 이용한 임신초기 태아의 두개내투명대 표준치 제시)

  • Yang, Sung-Hee;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.131-137
    • /
    • 2021
  • The purpose of this study was to present the reference value of the intracranial translucency(IT) of the fetus using the mid sagittal plane of the post brain in the early pregnancy ultrasound screening test and to find the clinical significance. From August 2018 to February 2020, the IT of 1529 singleton fetus whose crown lump length were 40.6 mm to 78.3 mm in length among the mothers undergoing regular checkups at Hospital I were measured and analyzed retrospectively. As the crown lump length increased, the IT showed a 54.3% explanatory power and tended to increase(p<0.001). In addition, through frequency analysis, the standard value for the percentile of the IT by gestational weeks was calculated. As a result, it was possible to establish a standard value for Koreans with an IT, and it will be usefully applied as an auxiliary screening test for spina bifida in the evaluation of fetal post brain in early pregnancy.

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

  • Su An Kim;Jaeho Shim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • Background: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. Objectives: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. Methods: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. Results: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 ㎛, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 ㎛, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 ㎛ with a 95% LoA span of 1,110.95 ㎛, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. Conclusions: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

Utility of Digital Rectal Examination, Serum Prostate Specific Antigen, and Transrectal Ultrasound in the Detection of Prostate Cancer: A Developing Country Perspective

  • Kash, Deep Par;Lal, Murli;Hashmi, Altaf Hussain;Mubarak, Muhammed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3087-3091
    • /
    • 2014
  • Purpose: To determine the utility of digital rectal examination (DRE), serum total prostate specific antigen (tPSA) estimation, and transrectal ultrasound (TRUS) for the detection of prostate cancer (PCa) in men with lower urinary tract symptoms (LUTS). Materials and Methods: All patients with abnormal DRE, TRUS, or serum tPSA >4ng/ml, in any combination, underwent TRUS-guided needle biopsy. Eight cores of prostatic tissue were obtained from different areas of the peripheral prostate and examined histopathologically for the nature of the pathology. Results: PCa was detected in 151 (50.3%) patients, remaining 149 (49.7%) showed benign changes with or without active prostatitis. PCa was detected in 13 (56.5%), 9 (19.1%), 26 (28.3%), and 103 (74.6%) of patients with tPSA <4 ng/ml, 4-10 ng/ml, 10-20 ng/ml and >20 ng/ml respectively. Only 13 patients with PCa had abnormal DRE and TRUS with serum PSA <4 ng/ml. The detection rate was highest in patients with tPSA >20 ng/ml. The association between tPSA level and cancer detection was statistically significant (p<0.01). Among 209 patients with abnormal DRE and raised serum PSA, PCa was detected in 128 (61.2%). Conclusions: The incidence of PCa increases with increasing serum level of tPSA. The overall screening and detection rate can be further improved by using DRE, TRUS and TRUS-guided prostate needle biopsies.

Transabdominal Ultrasound Assessment of the Polycystic Ovary Syndrome (다낭난소증후군 진단시 복식 초음파의 유용성에 관한 연구)

  • Jeong, Kyung-Ah;Lee, Woon-Jeong;Chung, Hye-Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2009
  • Objective: The objective of the study was to determine the diagnostic performance of transabdominal ultrasound by receiver operating characteristic (ROC) curve analysis, in order to evaluate the usefulness in establishing the diagnosis of polycystic ovary syndrome (PCOS). Methods: Questionnaires were given to 8,793 reproductive women reviewed at Ewha Womans University Mokdong hospital. Ultrasound examinations were performed in 701 women with a transabdominal transducer. Transabdominal ultrasounds were performed in 185 normal control women (normal menstruation without hyperandrogenism or PCO morphology) and 248 PCOS patients according to National Institutes of Health (NIH) PCOS diagnosis criteria. ROC curves were calculated for ovarian volume and follicle number. Results: In normal control group, the mean age were $23.64{\pm}4.26$ years old and the mean ovarian volume and follicle number were $6.03{\pm}1.89\;cm^3$ and $6.49{\pm}1.93$, respectively. The ovarian volume showed an area under the ROC curve (AURC) of 0.761. A ovarian volume decision threshold >$9\;cm^3$ had a sensitivity of 51.0% and a specificity of 91.4% for the diagnosis of PCOS. The follicle number showed an AURC of 0.733. A follicle number decision threshold ${\geq}9$ had a sensitivity of 54.9% and a specificity of 87.0% for the diagnosis of PCOS. A follicle number decision threshold ${\geq}10$ had a sensitivity of 53.2% and a specificity of 90.4%. A follicle number and a ovarian volume did not have a high diagnostic power for screening for PCOS. Conclusion: Our results suggest that transabdominal ultrasound assessment is not effective for the detection of PCOS in young women of reproductive age.