• Title/Summary/Keyword: Scientific fire investigation

Search Result 38, Processing Time 0.033 seconds

Generation and Detection of Discharge Signals in Deteriorated (열화된 저압용 콘센트에서 방전신호의 발생과 검출)

  • Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Kil, Gyung-Suk;Cho, Young-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF

A study on investigation in damage sector of Wooden Cultural propertices-Housing Sin Keom Dang of MakokSa & Kim, Joo Tae's house (목조문화재 파손요인에 관한 연구-마곡사 심검당, 김주태 가옥)

  • Kim, Sa-Dug;Lee, Young-Hee;Yoon, Hee-Sang
    • 보존과학연구
    • /
    • s.15
    • /
    • pp.104-127
    • /
    • 1994
  • Traditional architecture has structural limits after some terms because it almost made by wood elements. So in the name of 'Restoration', by anatural process, repair works are accomplished. But the repair works of traditional buildings have some problems in spite of best men power and technology. To overcome this problems, we need more detailed studies for examine the reasons of destruction in elements of wooden buildings. The life limits of wooden buildings are caused by natural circumstances and humanic circumstances, the former has bad effect on the damage in wooden buildings. There are various elements of damage in the wooden buildings, earthquake, the falling of a thunderbolt, fire, and rain, microorganism, insect, and so on. Moreover pollutions-sulfurous acid gas, acidorganic matters -are important reason of shortening the life of wooden buildings. From 1981 till now we investigated important traditional buildings under repair works by the way scientific analysis to catch the sample - seramics, woods, insects, metals, etc. In this reports we suggest various method of investigation with two samples of tradional house made by wood, one is Kim Joo Tea House, the order is Simgum-dang of Magok-Sa(dwelling of monk).

  • PDF

Study on the Performance Deterioration of Erosion-corrosion Damaged Automotive Water Pump (침식 마모 손상된 차량용 워터펌프의 성능저하 연구)

  • Jeon, Seung-Won;Park, Chan-Seong;Kim, Yoon-Ho;Lee, Kyu-Jung
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • A flow analysis for the erosion-corrosion damaged automotive water pump which causes vehicle fire is numerically performed using the CFX program, computational fluid dynamics (CFD) code. The blade bending deformation and the blade clearance enlargement are considered in the analysis of performance reduction. For the cavitation analysis, the homogeneous multi phase model is adopted using the Ralyleigh-Plesset model for the rate equation controlling vapor generation and condensation.

Analysis of Tripping Characteristics of Earth Leakage Circuit Breakers against Parallel Arcing (병렬아크에 대한 누전차단기의 트립특성 분석)

  • Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Cho, Young-Jin;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.478-479
    • /
    • 2007
  • Many electrical fires are occurred by leakage currents and sparks generated by a short circuit. Earth leakage circuit breakers (ELCBs) should be tripped at the moment of the faults mentioned above. In this paper, we described the tripping characteristics of ELCBs against parallel arcing faults. A diesel engine generator with the capacity of 375 kVA source was adopted to provide enough large current when a parallel arcing occurred. The experimental results showed that most ELCBs we experimented were not tripped against short-duration pulse currents produced by parallel arcing because the ELCBs are designed to be tripped by a large current with long duration similar to power frequency.

  • PDF

Forensic Engineering Study on Assessment of Damage to Pressure Vessel Because of CNG Vehicle Explosion (CNG 차량 폭발의 용기 손상 평가에 관한 법공학적 연구)

  • Kim, Eui-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.439-445
    • /
    • 2011
  • Forensic Engineering is the art and science of professionals qualified to serve as engineering experts in courts of law or in arbitration proceedings. Buses using compressed natural gas (CNG) trend to be extended in use internationally as optimal counterplan for reducing discharge gas of light oil due to high concern about environment. However, CNG buses have to be equipped with composite pressure vessels (CPVs); since the CPVs contain compressed natural gas, the risks in the case of accident is very high. Hence, the investigation of such accidents is usually associated with engineering analysis. Among the possible reasons for such CNG explosion accidents is vehicle fire and vessel fracture. By conducting formal inspection and engineering tests, in this study, the cause of vessel explosion is investigated by analyzing the failure mechanism by fractography and by comparing the material properties of a reference part with those of a problem part by adopting instrumented indentation technique.

Forensic Engineering Study on Assessment of Damage to Aerial Lifter Parts (고소작업차 부품 손상 평가에 관한 법공학적 연구)

  • Kim, Eui-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1727-1732
    • /
    • 2010
  • Forensic engineering is the area of expertise of people qualified to serve as engineering experts in courts of law or during arbitration proceedings. An aerial-lifter can lift and carry load, including people, using power. Recently, failure of aerial-lifter internal parts while working and sweeping causing injuries and damage to property almost always generates conflict between the automaker and customer. Hence, the investigation of such events generally involves an engineering analysis. One of the possible reasons for accidents, such as a vehicle catching fire is the failure of oil pressure machine and the supporting pin. The results of formal inspections and engineering tests can reveal the cause for the failure of the mechanical parts. Therefore, the failure mechanism is analyzed by adopting fractography methods and by applying an instrumented indentation technique to compare the material properties of the reference part with those of the malfunctioning part.

A case study of verifying a suicide by carbon monoxide intoxication committed by burning an ignition charcoal briquette (착화탄 연소에 의한 일산화탄소 중독사에서 자살입증에 관한 사례연구)

  • Sung, Tae-myung;Jo, Ju-ik;Ahn, Phil-sang
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.398-408
    • /
    • 2015
  • Carbon monoxide (CO) intoxication, arising from CO from an ignited charcoal briquette (ICB), is a popular means of committing suicide in Korea. Most CO intoxications are related to suicide attempts; however, the possibility of a homicide disguised as a suicide cannot be ruled out. Therefore, forensic investigation of the deceased and the crime scene is crucial to confirm that the deceased committed suicide. Detection of the components of an ICB on the objects suspected of being contacted by the deceased, such as the hands, nostrils, and doorknobs, is essential for linking the crime scene to the victim in the case of suicides by ignited ICBs. The traces from an ICB were analyzed by investigating the morphological characteristics and obtaining elemental compositions. The ICBs were completely different from blackened wood, as detected by discriminant analysis with the elements of carbon and oxygen. We analyzed one case of CO intoxication to demonstrate an excellent procedure for verifying whether a suicide occurred with an ICB. We employed SEM-EDX for the analysis of an ICB, microscope-FT/IR and pyrolysis-GC/MS for a partly burnt resin-type substance, GC/MS for diphenhydramine (a sleeping drug), and GC/TCD for the CO-Hb level. We detected traces of an ICB on the hands, nostrils, and doorknobs, which were all discriminated into an ICB group. Detection of ICB traces from the nostrils could indicate that the deceased started the fire themselves to commit suicide. The partially burnt black material was analyzed as an acrylronitrilestyrene polymer, which is normally used to make bags for carrying or wrapping and could be assumed to have been used to transport the ICB. Diphenhydramine, a sleeping drug, was detected at a level of 2.3 mg/L in the blood, which was lower than that in fatal cases (8-31 mg/L; mean 16 mg/L). A CO-Hb level of 79% was found in the blood, which means that the cause of death was CO intoxication. The steps shown here could represent an ideal method for reaching a verdict of suicide by CO intoxication produced by burning an ICB in a sealed room or a car.

Analysis of Fire Occurrence Characteristics According to Ignition Heat Sources (발화열원에 따른 화재발생 특성 분석)

  • Lee, Kyung-Su;Kim, Tae-Hyeung;Lee, Jae-Ou
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.280-289
    • /
    • 2022
  • Purpose: In this study, the characteristics of fire occurrence according to ignition heat sources such as operating equipment, cigarette/lighter fire, and flame/fire were analyzed. Method: One-way ANOVA and cross-analysis were used to analyze the characteristics of fire occurrence by verifying the difference between the ignition environment, fire damage status and scale, and cause of ignition according to the ignition heat source. Result: The fire occurrence characteristics were analyzed through As a result of the analysis, it was found that fires caused by operating devices occurred more frequently on weekdays than other ignition heat sources, and the number of victims and the number of victims were the highest, so mobilization of firefighting power and property damage were the greatest. The initial ignition was generated by electric and electronic devices, and the combustion was expanded by the synthetic resin. For fires caused by cigarette and lighter fires, the most fires occurred on Saturdays and Sundays, and the mobilization of the police force was more characteristic than the mobilization of the firefighting force. In particular, it was found that the initial ignition and combustion expansion were caused by paper, wood, and hay. Fires caused by sparks and sparks occurred most frequently on Saturdays and Sundays, and initial ignition and combustion expansion were found to be caused by paper, wood, and hay. In particular, it showed the characteristic that it occurred in the place farthest from the fire station. The common characteristic of all ignition heat sources was that the fire occurred most frequently in the afternoon time, and the fire type was predominantly the building structure fire, and only the ignition point was burned the most. Conclusion: In order to prevent fire and minimize damage, it is necessary to analyze the tendency of fire occurrence and to prepare appropriate preparations according to the fire occurrence factors. In order to analyze the characteristics of fire occurrence using public data in the future, it is necessary to standardize disaster data and to open and activate data.