• 제목/요약/키워드: School Building Cases

검색결과 242건 처리시간 0.022초

지속가능한 커뮤니티 관점에서 본 일본의 마을만들기 사례 분석 (Case Analysis of Machizukuri in Japan from the Perspective of Sustainable Community)

  • 김영주;박남희
    • 가정과삶의질연구
    • /
    • 제30권4호
    • /
    • pp.133-146
    • /
    • 2012
  • Community building in Japan, called Machizukuri, has been in existence since the 1960s, and many successful cases are referred to by researchers and public service officials as benchmarks for creating livable cities and towns in Korea. The purpose of this study is to identify the building factors for a sustainable community and to suggest implications through the cases of machizukuri in Japan. Based on the literature review related to the research topic, on-site visit case study was used as the major research methodology. Four cases -Setagaya, Kawagoe, Motomachi, and Manazuru- were selected as the research subjects and interviews with the representatives of the community(resident) council and public officials were conducted during October 19-22, 2011. The project overview, purpose, and planning characteristics of each case were described for data analysis. The major findings are as follows. Although most of the machizukuri in Japan were administration-dependent at the beginning stage, the case projects in this study showed resident-independence (self-support) from the perspective of sustainability. The results showed that successful community building is an everlasting project that requires cooperation among personnels including residents, civic officials, and related council members.

폐교시설(閉校施設)의 재활용(再活用) 특성(特性)에 관한 연구(硏究) - 경상북도지역(慶尙北道地域) 초등학교(初等學校) 폐교(閉校) 사례(事例)를 중심(中心)으로 - (A Study on the Recycled properties of the Closed School Facilities - Focused on the Recycling Situation of Closed School Facilities in Kyungsangpookdo province -)

  • 김성균;김현주;최무혁
    • 교육시설
    • /
    • 제8권3호
    • /
    • pp.15-23
    • /
    • 2001
  • The purpose of this study is to provide some architectural characteristics of recycled school facilities. To achieve this purpose literature review and case study are performed. In the case study total 207 recycled school facilities located within Kyungsangpookdo Province were analyzed in terms of its gross building area, size of the site, and new uses. Results of the analyses about the data show that there is a significant correlation between adapted use and size of the site and conditions of the adapted uses are influenced by the size of the site and gross building areas. In addition, this study finds that in case of extensions 53% of the total cases are used for training facilities. Finally, this study shows future research direction for achieving better decision in recycling closed school facilities.

  • PDF

온실형 자연형 태양열 학교교사의 성능 분석 연구 (A Performance Study on Passive Solar School Buildings with Sun Space)

  • 임상훈;전홍석;오정무
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.36-42
    • /
    • 1989
  • Following the oil crisis in 1979, there have been surge of movements by the government in Korea to conserve petroleum-based energy in every sector of society. One of these movements was the application of passive solar technologies into the construction of school buildings. Various passive designs are developed paying special regard to architectural and climatic factors. This paper is related to the application of the passive solar technology to elementary school buildings. It is proposed to place the hallway on the south side of the building to improve the thermal performance as well as indoor lighting effects. The cases have been compared with those of the existing school buildings where substantial improvements are noted. Finally, standard drawings are prepared in detail to promote the application of this passive solar technology in practical school building.

  • PDF

학교시설의 녹색건축인증 사례를 통한 평가부문별 분석 연구 (A Study on the Analysis about Assessment Criterion of the Green Building Certificate of School Facilities through the Case)

  • 김재영;이종국
    • 교육녹색환경연구
    • /
    • 제14권3호
    • /
    • pp.1-8
    • /
    • 2015
  • 본 연구는 친환경 인증을 받은 학교시설을 대상으로 예비인증 거쳐 본인증을 획득한 시설에서 친환경건축물인증 제도의 부문별 적용 및 득점 비율을 분석하여 문제점을 도출하고, 향후 친환경 인증학교시설 계획에 있어 설계자 및 관련 담당자에게 기초자료를 제공함에 목적이 있다. 본 연구의 범위는 2010 개정친환경건축물 인증 기준 이후 인증을 받은 신축 학교시설을 대상으로 하며 예비심사를 거쳐 본 인증을 획득한 10개교를 분석 대상으로 하였다. 분석 내용은 녹색건축 인증기준 2013 학교시설 인증심사기준(별표4)의 7개 평가 부문에 대해서 적용시설 및 득점비율을 조사 분석하였다.

일본 도쿄지역 프리스쿨 사례의 시설이용현황 조사연구 (A Study on the Architectural Facilities Utilization of Free Schools of Tokyo in Japan)

  • 정진주;이지영;임재한
    • 교육시설
    • /
    • 제15권1호
    • /
    • pp.53-61
    • /
    • 2008
  • Under recent educational and social backgrounds, alternative education schools are increasing continuously, to compare Japanese example that experience of similar circumstance given before with the investigation of general present condition, specialized education contents, facilities and utilization of 5 schools of Tokyo area, I could know following contents ; First, free schools of Tokyo area were operated by individual education type that consider each student's special quality maximum comparing with Korea's alternative schools which seek community education type. Second, there were not many schools which prescribe school personal allowance per division or class comparing with our cases that operate divides step by equal class with general school and prescribes personal allowance by class, and whole students are generally about $20{\sim}30$. Third, comparing with our cases that are located in mountain and rural area according to profitable locational conditions for environment and experience studying, it was general which islocatedin downtown for the purpose of free attending school of non attending school students. Fourth, usually, comparing with our that unused schools in mountain and rural area are general for alternative school and there were a lot of cases that uses small building of downtown such as lease office, unused warehouse and factory for free school of Tokyo area.

Component Analysis of Thermally Activated Building System in Residential Buildings

  • Chung, Woong June;Lee, Yu Ji;Yoo, Mi Hye;Park, Sang Hoon;Yeo, Myoung Souk;Kim, Kwang Woo
    • Architectural research
    • /
    • 제16권4호
    • /
    • pp.203-210
    • /
    • 2014
  • The packaged terminal air conditioner, the typical cooling system for the residential buildings, consumes a large amount of electricity in a short period time during peak hours. In order to reduce the peak load and conserve the electricity, the thermally activated building system can be used as a secondary system to handle the partial cooling load. However, the thermally activated building system may cause condensation and under-cooling. Thus, design of both systems should be performed with careful investigation in characteristics of both systems to amplify the advantages. Since the thermally activated building system has the time-delay effect which may cause under-cooling, the system is designed to handle the base load of the building. Hence, simple simulation with EnergyPlus was performed to observe the characteristics of cooling load in residential buildings. Once the possible range of the load handling ratio of the thermally activated building system was decided, characteristics of system was analyzed in terms of hardware component and operation parameters. The hardware components were analyzed in plant and system aspects and the operation parameter was evaluated in the thermal comfort aspect. As the load handling ratio increased, the thermal comfort increased due to the lower radiant mean temperatures. Within the range of thermal comfort, the several adjustments were made in setpoint temperature and electricity consumptions of difference cases were observed to decide which components and parameters were important for designing the systems.

휴대폰 앱을 이용한 건물 수평진동의 상시진동계측 (Ambient Vibration Measurement of Buildings Horizontal Vibration Using a Mobile Phone Application)

  • 문상현;윤성원
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.77-83
    • /
    • 2015
  • The cases of conducting the vibration measurement using the mobile phone with regard to the building's horizontal vibration are very rare in Korea and foreign countries. Therefore, this study analyzed the horizontal vibration nature of the building using the mobile phone targeting 5 tall buildings, and reviewed about the applicability of the mobile phone vibration measuring instrument through the comparison/verification with the data of the existing vibration measuring instrument. The peak of the measured time series waveform was measured clearly and it showed a similar value to the existing natural frequency.

Setting the New Trends for BIM in Construction: Productivity, Performance, Competitiveness, and Innovation

  • Wang, Xiangyu;Moon, Sungkon
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.21-22
    • /
    • 2015
  • Productivity has been a wide-ranging challenge for the construction industry, both in Australia and globally. Particularly in Western Australia's construction and resources sectors, continuously low productivity will potentially discourage future investments. The emergence of the global marketplace necessitates that the supply chain needs to focus on the concept of the holistic efficiency. The isolated geographical position of Australia only exacerbates this phenomenon. In recent years, Building Information Modelling (BIM) has been suggested as an efficient way to help productivity improve and information management throughout supply chains. This keynote talk will focus on discussing ways of implementing BIM to enhance site productivity focusing on Western Australia's construction projects. It will show new trends of its applications to accomplish an innovative way in construction project management. The talk will also give an insightful summary of integrated methods with state-of-the-art technologies backboned by the BIM cases from construction and oil and gas industry projects.

  • PDF

인필식 유닛모듈러 공법을 활용한 학교시설의 리모델링 계획시 영향요인 (A Study on Effect Factors of Using Infill Unit-Modular Construction for Remodeling plan of School Facilities)

  • 전영훈;김균태;김석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.138-139
    • /
    • 2016
  • In this study, we propose a way of infill unit-modular construction for school facilities and identify the main effect factors when planning a remodeling of the school facilities by using infill unit-modular construction. This study is limited to have document for domestic infill modular construction such as technical data, knowhow due to fewer cases and research. we expect to study on an practical alternative for infill modular housing specifically.

  • PDF

Evaluation of a Fungal Spore Transportation in a Building under Uncertainty

  • Moon, Hyeun Jun
    • Architectural research
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 2006
  • A fungal spore transportation model that accounts for the concentration of airborne indoor spores and the amount of spores deposited on interior surfaces has been developed by extending the current aerosol model. This model is intended to be used for a building with a mechanical ventilation system, and considers HVAC filter efficiency and ventilation rate. The model also includes a surface-cleaning efficiency and frequency that removes a portion of spores deposited on surfaces. The developed model predicts indoor fungal spore concentration and provides an indoor/outdoor ratio that may increase or decrease mold growth risks in real, in-use building cases. To get a more useful outcome from the model simulation, an uncertainty analysis has been conducted in a real building case. By including uncertainties associated with the parameters in the spore transportation model, the simulation results provide probable ranges of indoor concentration and indoor/outdoor ratio. This paper describes the uncertainty quantification of each parameter that is specific to fungal spores, and uncertainty propagation using an appropriate statistical technique. The outcome of the uncertainty analysis showed an agreement with the results from the field measurement with air sampling in a real building.