• Title/Summary/Keyword: Scattered X-Ray

Search Result 149, Processing Time 0.02 seconds

The imaging Anatomical Consideration of the Resonance of the Cranial Cavity (두개강 공명의 영상해부학적 고찰)

  • Lee, Dong-Myoung
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2000
  • Because vocal technique is the basis of singing a song beautifully, so this study was undertaken to use the scientific and correct technique in order to get much better musical expressions. Shimadzu X - ray remote control TV system was used for checking the supporting state of diaphragmatic respiration after 5, 10, 15, 20, 25 and 30 sec during phonation in the state of full inhalation between professional singer and non - professional singer. Shimadzu Magnet $nex-{\alpha}$(SMT -50CX/H) was used for examining the scattering state from the resonance of nasal cavity to that of cranial cavity on the basis of diaphragmatic respiration. The results obtained were summerized as follows : 1. The resonance of cranial cavity must be scattered by the energy of diaphragmatic respiration after gathering the foci of the fundamental 5 vowels. 2. while raising the epiglottis, the resonance of nasal cavity must be clearly in order to maintain the resonance of cranial cavity beautifully. 3. We can get musical expressions by maintaining the elasticity of diaphragmatic respiration.

  • PDF

FeCoB Films with Large Saturation Magnetization and High Magnetic Anisotropy Field to Attain High Ferromagnetic Resonance Frequency

  • Nakagawa, Shigeki;Hirata, Ken-Ichiro
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.155-158
    • /
    • 2013
  • FeCoB films were being prepared on a Ru underlayer by using the oblique incidence of sputtered and back-scattered particles which have a high in-plane magnetic anisotropy field $H_k$ above 400 Oe. It is suitable to attain such deposition condition when facing targets sputtering system. The in-plane X-ray diffraction analysis clarified that there is anisotropic residual stress which is the origin of the high in-plane magnetic anisotropy. The directional crystalline alignment and inclination of crystallite growth were also observed. Such anisotropic crystalline structures may affect the anisotropic residual stress in the films. The B content of 5.6 at.% was appropriate to induce such anisotropic residual stress and $H_k$ of 410 Oe in this experiment. The film with B content of 6 at.% possessed large saturation magnetization of 22 kG and high $H_k$ of 500 Oe. The film exhibited high ferromagnetic resonance frequency of 9.2 GHz.

The review of Non-Destructive Testing regarding railway vehicle (철도차량의 비파괴검사에 관한 고찰)

  • Kim Jung-Nam;Jang Gil-Soo;Park Young-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1097-1102
    • /
    • 2005
  • Non-Destructive Testing (NDT) is test method which finds the mechanical or natural or artificial defects of the interior or exterior of those without destructing materials and welded products. NDT is a means to assess the perfection of a component or system perfection. NOT images defects using scattered light, sound, electric current, magnetic fields and X-ray. Each NDT method has merits and demerits in the detecting ability of defects according to evaluated subjects. Defects can affect the serviceability of the material or structure, so NDT is important in guaranteeing safe operation as well as in quality control. In this review, we considered the methods of NDT applied to current railway vehicle manufacturing.

  • PDF

Textures of Claystones and Their Genetic Significances in the Cheonunsan Formation of the Hwasoon Area (화순지역 천운산층 중의 점토암의 조직과 그 성인적 의미)

  • 김수진;추창호;이동진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 1998
  • Textures of claystones of the Cheonunsan Formation in the Hwasoon area have been studied using optical microscope and electron microprobe. Microscopic images were observed under the optical microscope using the transmitted polarizing light from thin sections and under the electron microprobe using the back-scattered electron beam from the polished sections. Identification of minerals were made using X-ray diffraction analysis and chemical analysis by electon microprobe. Textural analyses show that the original sedimentary claystones rich in aluminium were subjected to metamorphism by which they changed to the metamorphosed claystone consisting mainly of chloritoid, quartz, andalusite and illite. Later intensive hydrothermal kaolinization of this metamorhosed claystones resulted in the formation of high-aluminous claystones rich in kaolinite exhibiting various complicated replacement textures.

  • PDF

Feasibility of the 3D Printing Materials for Radiation Dose Reduction in Interventional Radiology (인터벤션 시술 시 환자의 선량감소를 위한 3D 프린팅 재료의 적용성 평가)

  • Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • Interventional radiology is performed under real-time fluoroscopy, and patients are exposed to a wide range of exposures for a long period of time depending on the examination and procedure. However, studies on radiation protection for patients during an intervention are insufficient. This study aims to evaluate the doses exposed during the intervention and the applicability of 3D printing materials. The organ dose for each intervention site was evaluated using a monte carlo simulatio. Also, the dose reduction effect of the critical organs was calculated when using a shielding device using 3D printing materials. As a result, the organ dose distribution for each intervention site showed a lower dose distribution for organs located far from the x-ray tube. It was analyzed that the influence of scattered rays was higher in the superficial organs of the back of the human body where x-rays were incident. The dose reduction effect on the critical organ using the 3D printing shield showed the highest testis among the gonads, and in the case of other organs, the dose reduction effect gradually decreased in the order of the eye, thyroid, breast, and ovary. Accordingly, it is judged that the 3D printed shield will be sufficiently usable as a shielding device for the radiation protection of critical organs.

The Necessity of Resetting the Filter Criteria for the Minimization of Dose Creep in Digital Imaging Systems (디지털 영상 시스템에서 선량 크리프 최소화를 위한 부가 필터 두께 권고 기준의 재설정에 대한 연구)

  • Kim, Kyo Tae;Kim, Kum Bae;Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.757-763
    • /
    • 2019
  • Recently, Following the recent development of flat panel detector with wide dynamic ranges, increasing numbers of healthcare providers have begun to use digital radiography. As a result, filter thickness standards should be reestablished, as current clinical practice requires the use of thicknesses recommended by the National Council on Radiation Protection and Measurements, which are based on information, acquired using conventional analog systems. Here we investigated the possibility of minimizing dose creep and optimizing patient dose using Al filters in digital radiography. The use of thicker Al filters resulted in a maximum 19.3% reduction in the entrance skin exposure dose when medical images with similar sharpness values were compared. However, resolution, which is a critical factor in imaging, had a significant change of 1.01 lp/mm. This change in resolution is thought to be due to the increased amount of scattered rays generated from the object due to the X-ray beam hardening effect. The increase in the number of scattered rays was verified using the scattering degradation factor. However, the FPD, which has recently been developed and is widely used in various areas, has greater response to radiation than analog devices and has a wide dynamic range. Therefore, the FPD is expected to maintain an appropriate level of resolution corresponding to the increase in the scattered-ray content ratio, which depends on filter thickness. Use of the FPD is also expected to minimize dose creep by reducing the exposure dose.

Study on the Crystals in the Populus spp.(I) - Crystals in the Woods and Barks of Populus maximowiczii and Populuss nigra × maximowiczii (포풀라류의 결정에 관한 연구(I) - 황철나무와 양황철나무의 목부 및 수피종의 결정)

  • Lee, Kee-Young;Kim, Jae-Kyung;Kim, Nam-Hun;Park, Wan-Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-17
    • /
    • 2000
  • Crystals in the woods and barks of Populus maximowiczii and Populus nigra ${\times}$ maximowiczii were examined by light microscopy, scanning electron microscopy and soft X-ray. Populus examined had the wetwood and the heartwood of Populus showed higher moisture content than in adjacent sapwood. The crystals can be detected clearly by the soft X-ray due to their higher densities than the wood. Crystals in xylem wood of Populus were found mainly at heartwood. However, they were concentrated in specific areas such as in color-stained area or along the specific annual rings. Crystals showed the highest occurrence around the pith. Within a growth ring the amount of crystals in earlywood was more abundant than in latewood. Crystals were observed mainly at vessels and fibers although they occurred at all kinds of cells in heartwood. Crystals in the bark were scattered evenly both in inner bark and in outer bark. Populus nigra${\times}$maximowiczii showed higher frequency of leaf knots than Populus maximowiczii.

  • PDF

Pretreatment Condition of Cu by Ammonium-Based Mixed Solvent and Its Effects on the Fabrication of Ag-Coated Cu Particles (Ag 도금 Cu 입자의 제조에서 암모늄 기반 혼합 용매를 사용한 Cu 입자의 전처리 조건과 이의 영향)

  • Lee, Hee Bum;Lee, Jong-Hyun
    • Korean Journal of Materials Research
    • /
    • v.26 no.3
    • /
    • pp.109-116
    • /
    • 2016
  • To achieve the fabrication of high-quality Ag-coated Cu particles through a wet chemical process, we reported herein pretreatment conditions using an ammonium-based mixed solvent for the removal of a $Cu_2O$ layer on Cu particles that were oxidized in air for 1 hr at $200^{\circ}C$ or for 3 days at room temperature. Furthermore, we discussed the results of post-Ag plating with respect to removal level of the oxide layer. X-ray diffraction results revealed that the removal rate of the oxide layer is directly proportional to the concentration of the pretreatment solvent. With the results of Auger electron spectroscopy using oxidized Cu plates, the concentrations required to completely remove 50-nm-thick and 2-nm-thick oxides within 5 min were determined to be X2.5 and X0.13. However, the optimal concentrations in an actual Ag plating process using Cu powder increased to X0.4 and X0.5, respectively, because the oxidation in powder may be accelerated and the complete removal of oxide should be tuned to the thickest oxide layer among all the particles. Back-scattered electron images showed the formation of pure fine Ag particles instead of a uniform and smooth Ag coating in the Ag plating performed after incomplete removal of the oxide layer, indicating that the remaining oxide layer obstructs heterogeneous nucleation and plating by reduced Ag atoms.

Analysis of dose from surface to near the buildup region in the therapeutic X-ray beam (표피로 부터 buildup 영역까지 흡수되는 암치료용 방사선의 선량분석)

  • Vahc, Young-Woo
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.41-50
    • /
    • 1995
  • The absorbed dose and contaminant electron distribution of therapeutic X-ray beam (15MV photon) was studied with a half blocked beams of 30$\times$30$\textrm{cm}^2$ and field size ranging from 5$\times$5 to 30$\times$30$\textrm{cm}^2$. For a 15MV photon beam energy, the value of the depth of dose maximum, d$_{max}$, gradually decrease with increasing field size from 5$\times$5 to 30$\times$30$\textrm{cm}^2$ due to mainly by contaminant electrons which are produced in the flattening filter and scattered by collimator jaws, tray holder〔Lucite〕, blocking block and air. The results suggest that separate dosimetry data should be kept for blocked and unblocked field. The inherence of the contaminant electrons to the open field depth of maximum dose can lead to mistaken results if attenuation measurements are made at that depth. A nurmerous contaminant electrons mainly were distributed as shape of corn in the central photon beam and their path length in the water were shorter than 30mm because of the electrons energy having around 6MeV. These results clearly appears that the substraction of scattered electrons (electrons and positrons) from the total depth dose curve not only lowers the absolute dose in the bulidup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth. In the terapeutic high energy photon beam, the absorbed dose near the buildup region is the combined result of incident contaminant electrons and phantom generated electronsrons.

  • PDF

The Intensity Scale of Multiple Scattering of X-rays in Non-Crystalline Solids (비정질 고체에 대한 X선의 다중 산란 강도)

  • 박성수;장윤식;류봉기;박희찬
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.1
    • /
    • pp.109-113
    • /
    • 1997
  • When the intensity of X-rays scattered from amorphous materials (very weakly absorbing materials) is measured using standard diffractometric technique, the intensity caused by multiple scattering is obtained in the measured X-ray intensity. Computer programs have been developed to estimate the intensity of the mul-tiple scattering obtained in vitreous SiO2 and B2O3 with various X-rays. Using the above computer program, the intensity ratios of multiple scattering to single scattering in vitreous SiO2 were 0.10~0.16% at CuK$\alpha$, 0.98~5.87% at MoK$\alpha$, and 1.88~17.86% at AgK$\alpha$ in the range of 2$\theta$=0~180$^{\circ}$. Therefore, pri-or to the structural analysis of vitreous SiO2 and B2O3 performed experimentally using X-ray diffractometric technique, the intensity data measured in MoK$\alpha$ and AgK$\alpha$ radiations must be corrected for multiple scattering effect.

  • PDF