Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐 (Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy)

  • 추성실;서창옥;김귀언
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 의료용 선형가속기에서 발생되는 고 에너지 광자선은 콜리메이터에 의하여 누출되며 치료두부(head), 콜리메이터, 환자를 포함한 치료실내의 모든 벽과 구성 물질들에 의하여 많은 산란선이 발생된다. 방사선치료는 종양에 따라서 최소한 40 Gy에서 80 Gy까지 조사되기 때문에 주위건강조직 특히 생식가능한 사람에 대한 생식선의 피폭선량을 평가하여야하며 종양치료에 영향을 주지 않은 범위에서 가능한 방법을 동원하여 피폭선량을 줄여야한다. 방사선 안전관리등의 기술기준에 관한 규칙(과학기술부령 제17호) 제3절 의료분야의 특별기준, 제44조(진료환자의 방사선 피폭)에 의하면 진료를 위한 환자 피폭선량을 합리적으로 달성 가능한 최소의 수준으로 유지하기 위한 절차를 구비하여야 하며 과학기술부 장관은 이에 준하는 의료시설 및 장비취급의 기술기준을 정하고 고시하여야한다고 명시 되어있다. 고 에너지방사선은 악성종양환자들의 치료성과를 향상시키는 동시에 치료후 방사선에 의한 만성효과가 발생 될 수 있기 때문에 주선속의 다양한 산란선과 누출선의 선질변화와 선량을 측정하고 생식선과 같은 주요장기를 산란선으로부터 차폐할 수 있는 기구를 제작 사용함으로서 방사선 피폭선량을 최대한으로 감소시킬 수 있었다. 고 에너지 방사선은 의료용 선형가속기(CLINAC 2100C/D. 2100C. 600C)에서 발생시킨 4, 6, 10 MV x-ray와 코발트원격치료장치(ALCYON II)의 코발트선원에서 방출되는 1.25 MV의 감마선을 이용하였다. 선량측정은 폴리스틸렌과 인체팬텀(Rando)사용하였으며 측정기는 이온함, TLD 및 필름을 사용하였다. 고 에너지 방사선에 의한 산란선은 장치의 콜리메이터 뿐만 아니라 치료실 벽 인체내부등 모든 방향에서 방사됨으로 납 벽돌에 의한 차폐율측정은 많은 변수를 가졌으며 고환인 경우에는 3면이 모두 차폐되도록 항아리모양으로 제작하였다. 태아인 경우 태아가 위치하고 있는 골반위에 육교모양의 선반을 만들고 그 위에 납 벽돌을 장치하도록 고안하였다. Co-60 감마선, 4 MV x-선, 10 MV x-선에서 발생되는 누출선량과 산란선량에 의한 평균 피폭선량은 조사면 중심으로부터 10, 30, 60cm 거리에서 조사면내 최대선량에 대하여 각각 $10^{-2},\;10^{-3},\;10^{-4}$의 비율로 측정되었으며 거리에 따라 지수함수로 줄어들었다. 흉부에 국한된 종양을 10 MV x-ray, $12{\times}12 cm^2$ 조사면으로 치료하였을 때 자궁에 받는 피폭선량은 0.9 mGy/Gy이며 고환이 받는 피폭선량은 0.6 mGy/Gy 이었으며 체장과 신장은 각각 4.8 mGy/Gy 와 2.5 mGy/Gy이다 10 MV x-선, $14{\times}14cm^2$ 조사면 경계로부터 10 cm 밖에서 납벽돌의 반가층 두께는 약 9.0 mm 이였고 20cm 밖에서는 반가층 두께가 약 6.5 mm로 측정되었다. 복부에 위치한 악성종양을 60 Gy 조사하였을 경우 태아가 위치하고 있는 자궁의 피폭선량은 약 370 mGy이고 이곳을 10 mGy이하가 되도록 차폐하려면 약 6.2 cm두께의 납 벽돌을 자궁위에 장착하여야 하며 골반치료시 고환에 10 mGy이하가 되도록 차폐하려면 약 5 cm 두께의 납 항아리가 요구된다. 고 에너지 고 준위 방사선치료시 고환은 3면을 항아리모양으로 차폐할 수 있어 피폭선량을 상당히 줄일 수 있으며 자궁인 경우 체내에서 산란된 선량의 차폐는 불가능하였다.

Effects of collimator on imaging performance of Yttrium-90 Bremsstrahlung photons: Monte Carlo simulation

  • Kim, Minho;Bae, Jae Keon;Hong, Bong Hwan;Kim, Kyeong Min;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.539-545
    • /
    • 2019
  • Yttrium-90 is a useful therapeutic radioisotope for tumor treatment because of its high-energy-emitting beta rays. However, it has been difficult to select appropriate collimators and main energy windows for Y-90 Bremsstrahlung imaging using gamma cameras because of the broad energy spectra of Y-90. We used a Monte Carlo simulation to investigate the effects of collimator selection and energy windows on Y-90 Bremsstrahlung imaging. We considered both MELP and HE collimators. Various phantoms were employed in the simulation to determine the main energy window using primary-to-scatter ratios (PSRs). Imaging performance was evaluated using spatial resolution indices, imaging counts, scatter fractions, and contrast-to-noise ratios. Collimator choice slightly affected energy spectrum shapes and improved PSRs. The HE collimator performed better than the MELP collimator on all imaging performance indices (except for imaging count). We observed minor differences in SR and SF values for the HE collimator among the five simulated energy windows. The combination of an HE collimator and improved-PSR energy window produced the best CNR value. In conclusion, appropriate collimator selection is an important component of Bremsstrahlung Y-90 photon imaging and main energy window determination. We found HE collimators to be more appropriate for improving the imaging performance of Bremsstrahlung Y-90 photons.

6 MV 광자선의 투과성필터와 Wedge 선속을 이용한 부비강의 균등선량계획 (Homogeneous Dose Planning to Paranasal Sinus with the Partial Attenuation filters and Wedged Beams in 6 MV Photon Beam)

  • 최태진;이호준;김옥배
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.183-191
    • /
    • 1993
  • The homogeneous dose planning is one of the most important roles in radiation therapy. But, it is not easy to obtain a homogeneous dose to paranasal sinus region including the ethmoidal sinus with conventional irradiation techniques. In this experimental study, the authors tried to get a homogeneous dose at PNS region, but the nasal cartirage does not exceed the tolerance dose, with anterior-posterior beam and two both lateral wedged beams. Used three fields were shielded with full thickness of blocks to preserve the eye-balls and with blocks of one half value layer to create a homogeneous dose at the whole treatment volume. The dose computations are based on the three dimensonal structure with modified scatter contributions of partial shielders and attenuated beams in 6 MV photon beams. The dose distributions of mid-plane is examined with Kodak verification films and teflon-embedded TLD rod (1 mm diameter and 6 mm length) to confirm the computed dose. In our study, the whole PNS regions have shown within $85{\%}$ of the resultant isodose curves with relatively homogeneous dose distribution. The results of dose computation and measurements are agree well within $5{\%}$ uncertainties.

  • PDF

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

SPECT와 PET을 이용한 심장관류 및 기능의 정량화 (Quantification of Myocardial Perfusion and Function Using SPECT and PET)

  • 이재성
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.75-81
    • /
    • 2005
  • Myocardial perfusion and function can be quantified using SPECT and PET. There was controversy over the usefulness of the correction techniques for physical artifacts, such as photon attenuation and scatter, in the quantification of myocardial perfusion using SPECT. However, the cumulated results of many investigations have leaded the consensus on the usefulness of the correction procedures to improve the accuracy and specificity of the myocardial SPECT in the assessment of coronary artery diseases. Although the clinical value of the myocardial perfusion PET has not been preyed yet, the absolute myocardial blood flow and perfusion reserve values quantified using myocardial PET are employed in many basic investigations. In this paper, the methods for the quantitative myocardial SPECT and PET will be reviewed.

Dust Scattering in Turbulent Media: Correlation between the Scattered Light and Dust Column Density

  • Seon, Kwang-Il;Witt, Adolf N.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.59.2-59.2
    • /
    • 2014
  • Radiative transfer models in a spherical, turbulent interstellar medium (ISM), in which the photon source is situated at the center, are calculated to investigate the correlation between the scattered light and the dust column density. The medium is modeled using fractional Brownian motion structures that are appropriate for turbulent ISM. The correlation plot between the scattered light and optical depth shows substantial scatter and deviation from simple proportionality. It was also found that the overall density contrast is smoothed out in scattered light. In other words, there is an enhancement of the dust-scattered flux in low-density regions, while the scattered flux is suppressed in high-density regions. The correlation becomes less significant as the scattering becomes closer to being isotropic and the medium becomes more turbulent. Therefore, the scattered light observed in near-infrared wavelengths would show much weaker correlation than the observations in optical and ultraviolet wavelengths. We also find that the correlation plot between scattered lights at two different wavelengths shows a tighter correlation than that of the scattered light versus the optical depth.

  • PDF

조사문 선량 분포와 Monte Carlo 계산을 이용한 삼차원 선량 재구성에 관한 연구 (Three dimensional Dose reconstruction based on transit dose measurement and Monte Carlo calculation)

  • 박달;여인환;김대용;안용찬;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.91-99
    • /
    • 2000
  • 본 연구는 선형 가속기에서 나오는 고 에너지 광자빔 조사를 받은 환자 내부의 선량 분포를 조사문 선량 분포로부터 재구성하는 방법을 개발하기 위한 기초 연구로서 삼차원 선량 분포를 재구성하는 방법을 제시하고 이 방법을 전산모사를 통해 평가하였다. 본 연구에서 제안하는 방법은 환자나 팬톰 내부의 임의의 지점에서 흡수된 선량과 그 지점에 대응되는 조사문 선량의 측정 지점에서 흡수된 선량의 차이를 계산하여 측정된 조사문 선량 분포로부터 환자나 팬톰 내부의 선량분포를 얻는 것이다. 선량의 차이는 역제곱법칙과 선형감쇄계수, 그리고 Monte Carlo 프로그램을 이용하여 환자나 팬톰의 CT 정보로부터 계산한 산란선량과 주선량의 비(scatter to primary dose ratio)를 이용하여 계산한다. 이 방법을 시험하기 위해 여러 종류의 균질 혹은 비균질 팬톰의 조사문 선량 분포를 Monte Carlo 전산모사로 계산한 뒤 팬톰 내부의 선량 분포를 재구성하였다. 광자빔은 1.5 MeV의 단일에너지를 사용하였고 Monte Carlo 프로그램은 EGS4를사용하였다. 본 연구의 방법을 사용하여 재구성된 팬톰 내부의 선량 분포와 Monte Carlo로 계산한 팬텀 내부의 선량 분포와 비교하였다. 비교 결과 오차 -4%∼+2% 이내로 일치하였다. 이 방법은 다른 in vivo dosimetry 방법을 대신하여 환자내의 선량분포를 예측하는데 쓰여질 수 있을 것이다.

  • PDF

광자선에 의한 민조사면 경계영역의 선량분포 (Peripheral Dose Distributions of Clinical Photon Beams)

  • 김진기;김정수;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.71-77
    • /
    • 2001
  • 방사선조사면의 가장자리는 반음영 영역으로 선량변화가 급격한 부분이다. 이러한 부분은 메가볼트 광자선 영역의 조사면에서 선원크기, 콜리메이터, 차폐불럭, 보조기구 그리고 내부산란선에 의한 것으로 알려져 있다. 본 연구에서는 기준조사면 경계 영역의 선량특성을 확인하고 선험적인 이론적 관계식으로 비교하여 치료시스템 조사면의 특성을 알고자 하였다. 조사면 경계영역의 주변선량분포를 깊이와 중심축으로부터 거리의 함수로서 구성하여 6MV 광자선에 의한 민조사면 경계영역의 주변선량분포를 측정하고 이를 선험적인 함수분포와 비교하였다. 3차원 물 팬톰으로 조사면 가장자리 영역의 주변선량분포를 측정하고 이를 선험적인 함수값과 비교하여 측정치와 근접한 함수방법을 알아보았다. 반도체 검출기와 전리함으로 최대선량점, 5 cm , 10 cm 깊이의 위치에서 측정값의 비를 이용하고, 유효 가장자리 영역은 80-20 % 를 선택하여 거리의 함수로 분석하였다. 깊이가 증가함에 따라경계영역의 선량폭이 증가하였다. 주변선량분포에서 검출기의 특성에 따라서 측정값과 함수값에 작은 차이가 있었다. 민조사면 경계영역 선량 분포함수를 비교하였다.

  • PDF

광자선 소조사면에 대한 다이아몬드 검출기의 선량특성에 관한 연구 (A Study of Dosimetric Characteristics of a Diamond Detector for Small Field Photon Beams)

  • 노준규;박성용;신동오;권수일;이길동;김우철;조영갑
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.195-203
    • /
    • 1999
  • 고 에너지 광자선 소조사면에 대한 선량 특성은 조사면내의 급격한 선량 변화와 측면 전자 평형상태하의 측정이 어려우므로 정확하게 파악하기 어렵다. 다이아몬드 검출기를 이용하여 광자선 에너지 4, 6, 그리고 10 MeV에 대한 소조사면의 선량특성을 측정하였고 그 값들을 작은 용적의 원통형과 평행평판형 이온함의 선량특성과 비교하였다. 다이아몬드 검출기와 원통형 이온함을 이용하여 의료용 선형가속기에서 방출되는 광자선 에너지 6 MeV X-선, 10 MeV X-선에 대한 소조사면($1{\times}1,\;1.5{\times}1.5,\;2{\times}2,\;3{\times}3,\;4{\times}4\;cm^2$)에 대하여 심부선량백분율, 측면 선량분포를 측정하였다. 또한 다이아몬드 검출기, 원통형 이온함 및 평행평판형 이온함을 이용하여 광자선 에너지 4 MeV X-선, 6 MeV X-선 및 10 MeV X-선으로 소조사면의 크기를 $1{\times}1\;cm^2$에서 $0.5\;cm^2$간격으로 $4{\times}4\;cm^2$까지 변화하면서 출력계수를 측정하였다. 세 가지 측정기에 대한 출력계수를 비교한 결과 광자선 에너지 4 MeV X-선은 조사면의 크기 $2{\times}2\;cm^2$, 6 MeV X-선은 $2.5{\times}2.5\;cm^2$ 그리고 10 MeV X-선은 $3{\times}3\;cm^2$이상에서 출력계수가 $\pm$1.2% 내외로 잘 일치하였으나 원통형과 평행평판형 이온함에 대한 출력계수는 조사면의 크기가 작아질수록 다이아몬드의 검출기와 비교하여 낮게 평가되었는데 이는 원통형과 평행평판형 이온함의 측면전자평형상태가 이루어지지 않아 낮게 평가되었다. 광자선 에너지 6 MeV X-선과 10 MeV X-선에 대한 심부선량백분율은 다이아몬드 검출기와 원통형 이온함이 조사면의 크기 $3{\times}3\;cm^2$까지 $\pm$1.5% 내외로 잘 일치하였으나 조사면의 크기가 작고 깊이가 깊어짐에 따라 다이아몬드의 심부선량백분율이 크게 평가되었다. 측면 선량분포는 원통형 이온함의 반음영의 크기가 측정된 소조사면에 대하여 다이아몬드 검출기보다 크게 나타났다. 측면 선량분포는 다이아몬드 검출기가 상대적으로 이온함에 비해 민감 용적이 작고 높은 분해능을 가지므로 반음영이 작은 것으로 사료된다. 따라서 고 에너지 광자선 소조사면에 대한 선량 측정시 검출기의 민감 용적이 작고 분해능이 우수하며 물과 등가인 다이아몬드 검출기는 이온함에 비해 상대적으로 우수한 것으로 생각된다.

  • PDF