Three dimensional Dose reconstruction based on transit dose measurement and Monte Carlo calculation

조사문 선량 분포와 Monte Carlo 계산을 이용한 삼차원 선량 재구성에 관한 연구

  • Park, Dal (Department of Radiation Oncology, Samsung medical Center, School of Medicine, Sungkyunkwan University) ;
  • Yeo, In-Hwan (Department of Radiation Oncology, Samsung medical Center, School of Medicine, Sungkyunkwan University) ;
  • Kim, Dae-Yong (Department of Radiation Oncology, Samsung medical Center, School of Medicine, Sungkyunkwan University) ;
  • An, Yong-Chan (Department of Radiation Oncology, Samsung medical Center, School of Medicine, Sungkyunkwan University) ;
  • Heo, Seung-Jae (Department of Radiation Oncology, Samsung medical Center, School of Medicine, Sungkyunkwan University)
  • 박달 (성균관대학교 의과대학 삼성서울병원 치료방사선과) ;
  • 여인환 (성균관대학교 의과대학 삼성서울병원 치료방사선과) ;
  • 김대용 (성균관대학교 의과대학 삼성서울병원 치료방사선과) ;
  • 안용찬 (성균관대학교 의과대학 삼성서울병원 치료방사선과) ;
  • 허승재 (성균관대학교 의과대학 삼성서울병원 치료방사선과)
  • Published : 2000.09.01

Abstract

This is a preliminary study for developing the method of the dose reconstruction in the patients, irradiated by mega-voltage photon beams from the linear accelerator, using the transit dose distributions. In this study we present the method of three-dimensional dose reconstruction and evaluate the method by computer simulation. To acquire the dose distributions in the patients (or phantoms) we first calculate the differences between the doses at the arbitrary points in the patients and the doses at the corresponding points where the transit doses are measured. Then, we can get the dose in the patients from the measured transit dose and the calculated value of the difference. The dose differences are calculated by applying the inverse square law and using the linear attenuation coefficient. The scatter to primary dose ratios, which are calculated by the Monte Carlo program using the CT data of the patient (or phantoms), are also used in the calculations. For the evaluation of this method we used various kinds of homogeneous and inhomogeneous phantoms and calculated the transit dose distributions with the Monte Carlo program. From the distributions we reconstructed the dose distributions in the phantom. We used mono-energy Photon beam of 1.5MeV and Monte Carlo program EGS4. The comparison between the dose distributions reconstructed using the method and the distributions calculated by the Monte Carlo program was done. They agreed within errors of -4%∼+2%. This method can be used to predict the dose distributions in the patient

본 연구는 선형 가속기에서 나오는 고 에너지 광자빔 조사를 받은 환자 내부의 선량 분포를 조사문 선량 분포로부터 재구성하는 방법을 개발하기 위한 기초 연구로서 삼차원 선량 분포를 재구성하는 방법을 제시하고 이 방법을 전산모사를 통해 평가하였다. 본 연구에서 제안하는 방법은 환자나 팬톰 내부의 임의의 지점에서 흡수된 선량과 그 지점에 대응되는 조사문 선량의 측정 지점에서 흡수된 선량의 차이를 계산하여 측정된 조사문 선량 분포로부터 환자나 팬톰 내부의 선량분포를 얻는 것이다. 선량의 차이는 역제곱법칙과 선형감쇄계수, 그리고 Monte Carlo 프로그램을 이용하여 환자나 팬톰의 CT 정보로부터 계산한 산란선량과 주선량의 비(scatter to primary dose ratio)를 이용하여 계산한다. 이 방법을 시험하기 위해 여러 종류의 균질 혹은 비균질 팬톰의 조사문 선량 분포를 Monte Carlo 전산모사로 계산한 뒤 팬톰 내부의 선량 분포를 재구성하였다. 광자빔은 1.5 MeV의 단일에너지를 사용하였고 Monte Carlo 프로그램은 EGS4를사용하였다. 본 연구의 방법을 사용하여 재구성된 팬톰 내부의 선량 분포와 Monte Carlo로 계산한 팬텀 내부의 선량 분포와 비교하였다. 비교 결과 오차 -4%∼+2% 이내로 일치하였다. 이 방법은 다른 in vivo dosimetry 방법을 대신하여 환자내의 선량분포를 예측하는데 쓰여질 수 있을 것이다.

Keywords