• Title/Summary/Keyword: Scatter materials

Search Result 125, Processing Time 0.028 seconds

The Microstructure and Microwave Dielectric Properties of Ceramics in the System CaTiO3-Li0.5Nd0.5TiO3

  • Lowe, Tristan;Azough, Feridoon;Freer, Robert
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.4
    • /
    • pp.328-332
    • /
    • 2003
  • Ceramics of xCaTiO$_3$-(1-x)Li$_{0.5}$Nd$_{0.5}$TiO$_3$(xCT-(1-x)LNT) series have been prepared by the mixed oxide route. Powders were calcined at 110$0^{\circ}C$ ; cylindrical specimens were fired at temperatures in the range 1300-150$0^{\circ}C$. Sintered products were typically 90-95% dense. The microstructures were dominated by angular grains typically 1.3${\mu}{\textrm}{m}$ to 3.5 ${\mu}{\textrm}{m}$ in size. Twinning in the microstructures was analysed using Electron Back Scattered Diffraction (EBSD). Microwave dielectric properties of xCT-(1-x)LNT at 2.1 GHz ($\varepsilon$$_{r}$, Qxf, and $\tau$r) were 170,3800 GHz and 744 ppm/$^{\circ}C$ for pure CaTiO$_3$ and 80,2000 GHz and -240 ppm/$^{\circ}C$ for LNT. The $\tau$r decreases almost linearly from 744 for pure CaTiO$_3$ to -240 for pure LNT.LNT.T.

Probabilistic Model of Service Life to Evaluate Damage Tolerance of Composite Structure (복합재 항공구조물의 손상허용평가를 위한 운항수명의 확률적 모델)

  • A.스튜어트;A.우샤코프;심재열;황인희
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.245-248
    • /
    • 2000
  • Modern aircraft composite structures are designed using a damage tolerance philosophy. This design philosophy envisions sufficient strength and structural integrity of the aircraft to sustain major damage and to avoid catastrophic failure. The only reasonable way to treat on the same basis all the conditions and uncertainties participating in the design of damage tolerant composite aircraft structures is to use the probability-based approach. Therefore, the model has been developed to assess the probability of structural failure (POSF) and associated risk taking into account the random mechanical loads, random temperature-humidity conditions, conditions causing damages, as well as structural strength variations due to intrinsic strength scatter, manufacturing defects, operational damages, temperature-humidity conditions. The model enables engineers to establish the relationship between static/residual strength safety margins, production quality control requirements, in-service inspection resolution and criteria, and POSF. This make possible to estimate the cost associated with the mentioned factors and to use this cost as overall criterion. The methodology has been programmed into software.

  • PDF

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Recent Developments in Nuclear Medicine Instrumentation (최근 핵의학 영상 기기 발전 동향)

  • Kim, Joon-Young;Choi, Yong;Kim, Jong-Ho;Im, Ki-Chun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Sang-Eun;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.471-481
    • /
    • 1998
  • The goals of developments in nuclear medicine instrumentation are to offer a higher-quality image and to aid diagnosis, prognosis assessment or treatment planning and monitoring. It is necessary for physicists and engineers to improve or design new instrumentation and techniques, and to implement, validate, and apply these new approaches in the practice of nuclear medicine. The researches in physical properties of detectors and crystal materials and advances in image analysis technology have improved quantitative and diagnostic accuracy of nuclear medicine images. This review article presents recent developments in nuclear medicine instrumentation, including scatter and attenuation correction, new detector technology, tomographic image reconstruction methods, 511 keV imaging, dual modality imaging device, small gamma camera, PET developments, image display and analysis methods.

  • PDF

The Broad-beam CT Image Reconstruction from Simulator Images (모의치료(Simulation) 영상을 이용한 Broad-beam CT 영상 구현)

  • Yi, Byong-Yong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.81-86
    • /
    • 1998
  • Purpose : To generate the axial, coronal and sagittal images from conventional simulation images, as a preliminary study of broad-beam simulator CT. Methods and Materials : Volumetric filtered back-projection was performed using 90 sheets of films from conventional simulator for every $4^{\circ}$ gantry angle. Two mAs exposure condition for 120kvp beam qualify at SFD 140cm was given to each film. Outside the silhouette portion was removed and scatter component was deconvolved before back-projection. Results : The axial, the sagittal and the coronal images with same spatial resolutions over all direction could be obtained. But image quality was very poor. Conclusion : CT images could be obtained using broad-beam. Scatter deconvolution technique was effective for this reconstruction. The fact that same spatial resolutions over all direction tells us the possibility of application of this technique to DRR or Simulator-CT. But the quality of image should be improved for clinical application practically.

  • PDF

Statistical Analysis of the Springback Scatter according to the Material Strength in the Sheet Metal Forming Process (판재성형공정에서의 소재 강도에 따른 스프링백 산포의 통계분석)

  • Son, Min-Kyu;Kim, Se-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.287-292
    • /
    • 2022
  • In this paper, the stochastic distribution of the springback amount is investigated for the stamping process of a U-channel shaped-product with ultra-high strength steel. Using the reliability-based design optimization technique (RBDO), stochastic distribution of process parameters is considered in the analysis including material properties and process variation. Quantification of the springback scatters is carried out with the statistical analysis method according to the material strength. It is found that the scattering amount of springback decreases while the amount of springback increases as the tensile strength of the blank material increases, which is investigated by analyzing the strain and stress distribution of the punch and die shoulder. It is noted that the proposed scheme is capable of predicting and responding to the unavoidable scattering of springback in the sheet metal forming process.

Evaluation of a Conjugate View Method for Determination of Kidney Uptake (신장 방사선 섭취량 결정을 위한 Conjugate View 방법에 대한 평가)

  • Bong, Jung-Kyun;Yun, Mi-Jin;Lee, Jong-Doo;Kim, Hee-Joung;Son, Hye-Kyung;Kwon, Yun-Youug;Park, Hae-Jeong;Kim, Yu-Seun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.191-199
    • /
    • 2005
  • Purpose: In order to obtain better quantitation of kidney uptake, this study is to evaluate a conjugate view method (CVM) using a geometric mean attenuation correction for kidney uptake and to compare it to Gate's method. Materials & Methods: We used a Monte Carlo code, SIMIND and a Zubal phantom, to simulate kidney uptake. SIMIND was both simulated with or without scatter for the Zubal phantom. Also, a real phantom test was carried out using a dual-head gamma camera. The activity of 0.5 mCi was infused into two small cylinder phantoms of 5 cm diameter, and then, they were inserted into a cylinder phantom of 20 cm diameter. The results by the CVM method were compared with ideal data without both of attenuation and scatter and with Gate's method. The CVM was performed with or without scatter correction. The Gate's method was performed without scatter correction and it was evaluated with regards to $0.12cm^{-1}\;and\;0.15cm^{-1}$ attenuation coefficients. Data were analyzed with comparisons of mean counts in the legions of interest (ROI), profiles drawn over kidney images and linear regression. Correlation coefficients were calculated with ideal data, as well. Results: In the case of the computer simulation, mean counts measured from ideal data, the CVM and the Gate's method were (right $998{\pm}209$, left: $896{\pm}249$), (right: $911{\pm}207$, left: $815{\pm}265$), and (right: $1065{\pm}267$, left: $1546{\pm}267$), respectively. The ideal data showed good correlation with the CVM and the correlation coefficients of the CVM, Gate's method were (right: 0.91, left: 0.93) and (right: 0.85, left: 0.90), respectively. Conclusion: The conjugate view method using geometric mean attenuation correction resulted in better accuracy than the Gate's method. In conclusion, the conjugate view method independent of renal depths may provide more accurate kidney uptake.

Effect of Effective Grain Size on Charpy Impact Properties of High-Strength Bainitic Steels (베이나이트계 고강도강의 샤르피 충격 특성에 미치는 유효결정립도 영향)

  • Shin, Sang Yong;Han, Seung Youb;Hwang, Byoungchul;Lee, Chang Gil;Lee, Sunghak
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.10
    • /
    • pp.617-626
    • /
    • 2008
  • This study is concerned with the effect of Cu and B addition on microstructure and mechanical properties of high-strength bainitic steels. Six kinds of steels were fabricated by varying alloying elements and hot-rolling conditions, and their microstructures and tensile and Charpy impact properties were investigated. Their effective grain sizes were also characterized by the electron back-scatter diffraction analysis. The tensile test results indicated that the B- or Cu-containing steels had the higher yield and tensile strengths than the B- or Cu-free steels because their volume fractions of bainitic ferrite and martensite were quite high. The B- or Cu-free steels had the higher upper shelf energy than the B- or Cu-containing steels because of their higher volume fraction of granular bainite. In the steel containing 10 ppm B without Cu, the best combination of high strengths, high upper shelf energy, and low energy transition temperature could be obtained by the decrease in the overall effective grain size due to the presence of bainitic ferrite having smaller effective grain size.

The Friction Properties on the Loosening of Bolted Joints (I: Thread Friction Experiments) (볼트 결합부 풀림에 관한 마찰 특성 (제 I 보 : 나사 마찰 실험))

  • ;;Yanyao Jiang;Ming Zhang
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • By using an approach developed to determine the torque-tension relationship for bolted joints, frictional properties of several typical bolted joints were studied experimentally. The specific property by bolted joints certify that the most significant influence of materials and bearing surface condition. Experiments on thread friction shows that prevailing torque nuts with distorted threads provide benefit for preventing self-loosening of the nut. Repeated tightening-loosening generally increases frictions in a bolted joint. It was noted that the data scatter of the experimental results of frictions in a belted joint may overshadow the influence of size. speed, and contact positions. The results from the experimental investigation will help to better design bolted joints.

Effect of Heat Treatment Conditions on Corrosion and Hydrogen Diffusion Behaviors of Ultra-Strong Steel Used for Automotive Applications

  • Park, Jin-seong;Seong, Hwan Goo;Kim, Sung Jin
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.267-276
    • /
    • 2019
  • The purpose of this study was to examine the influence of conditions for quenching and/or tempering on the corrosion and hydrogen diffusion behavior of ultra-strong automotive steel in terms of the localized plastic strain related to the dislocation density, and the precipitation of iron carbide. In this study, a range of analytical and experimental methods were deployed, such as field emission-scanning electron microscopy, electron back scatter diffraction, electrochemical permeation technique, slow-strain rate test (SSRT), and electrochemical polarization test. The results showed that the hydrogen diffusion parameters involving the diffusion kinetics and hydrogen solubility, obtained from the permeation experiment, could not be directly indicative of the resistance to hydrogen embrittlement (HE) occurring under the condition with low hydrogen concentration. The SSRT results showed that the partitioning process, leading to decrease in localized plastic strain and dislocation density in the sample, results in a high resistance to HE-induced by aqueous corrosion. Conversely, coarse iron carbide, precipitated during heat treatment, weakened the long-term corrosion resistance. This can also be a controlling factor for the development of ultra-strong steel with superior corrosion and HE resistance.