• Title/Summary/Keyword: Scanning laser

Search Result 1,390, Processing Time 0.026 seconds

3D Extraction Method Using a Low Cost Line Laser (라인레이저를 이용한 3D 모델 추출 방법)

  • Yun, Chun Ho;Kim, Tae Gi;Cho, Yong Wook;Nam, Gi Won;Yim, Choong Hyuk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.1
    • /
    • pp.108-113
    • /
    • 2017
  • In this paper, we proposed a three-dimensional(3D) scanning system based on laser vision technique for 3D model reconstruction. The proposed scanning system consists of line laser, camera, and turntable. We implemented the 3D scanning system using low quality elements. Although these are low quality elements, we reduced the 3D data reconstruction errors greatly using two methods. First, we developed a maximum brightness detection algorithm. This algorithm extracts the maximum brightness of the line laser to obtain the shape of the object. Second, we designed a new laser control device. This device helps to adjust the relative position of the turntable and line laser. These two methods greatly reduce the measuring noise. As a result, point cloud data can be obtained without complicated calculations.

Analysis of Frequency Response of Piezo Stages and Scanning Path Monitoring/Compensation for Scanning Laser Optical Tweezers (주사 레이저 광집게를 위한 압전 구동기 주파수 특성 분석과 주사 경로 추적 및 보상)

  • Hwang, Sun-Uk;Lee, Song-Woo;Lee, Yong-Gu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.132-139
    • /
    • 2008
  • In scanning laser optical tweezers, high speed scanning stages are used to manipulate a laser beam spot. Due to the inertia of the stage, the output scanning signal decreases with increased frequency of the input signal. This discrepancy in the signals is difficult to observe since most of the energy from the laser beam is blocked out to avoid CCD damage. In this paper, we propose two methods to alleviate these problems. Firstly, frequency responses of piezo stages are measured to analyze the signal drops and the input signal is compensated accordingly. Secondly, an overlay of the scanning path is drawn on the live monitoring screen to enhance the visibility of the scanning path. The result is a drop-compensated scanning with clear path view.

Three-dimensional vibration measurement algorithm using one laser scanning vibrometer (한대의 LSV 를 이용한 3 차원 진동측정방법)

  • Kim, Dong-Kyu;Song, Ha-Jun;Park, Kyi-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.935-939
    • /
    • 2012
  • 3D vibration measurement is achieved using one laser scanning vibrometer(LSV) and Laser scanner(LS) by moving the LSV to three arbitrarily locations from the principle that vibration analysis based on the frequency domain is independent of the vibration signal based on time domain. The proposed system has the same effect as using three sets of LSVs. It has an advantage of reducing equipment costs. Analytical approach of obtaining in-plane and out-of-plane vibration of surface is introduced using geometrical relations between three LSV coordinates and vibration measured at three different locations.

  • PDF

Laser scanning unit with plastic f$\theta$ lenses featuring high resolution (600DPI용 플라스틱 f$\theta$렌즈가 실장된 Laser Scanning Unit 의 측정 및 평가)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.364-368
    • /
    • 1999
  • We investigate the evaluation items of LSU (Laser Scanning Unit), such as beam size, f$\theta$ characteristics, linearity, skew and bow, optical power ratio between image height of 0mm and $\pm$108 mm, pitch error, Jitter and shift of printing position. Through the measurement of LSU using BSH (Beam Scan Head) installed on LMC (Linear Motion Controller) which moves linearly within the whole scanning range (-108 mm~+108 mm), we can ascertain plastic f$\theta$ lenses, which are manufactured by TVLP (Two-step Variable Low Pressure) molding method, to satisfy 600DPI(Dots Per Inch) performance.

  • PDF

QUANTITATIVE ANALYSIS OF MINERAL CHANCE IN THE INITIAL CAR10US LESION USING CONFORMAL LASER SCANNING MICROSCOPY (공초점 레이저 주사 현미경을 이용한 법랑질 초기 우식 재광화의 정량적 분석)

  • 차승우;윤태철;박성호;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Dental Caries which has high prevalence rate, accounts for majority of dental diseases. Many treatment and preventive treatment has been developed, thereby reducing the prevalence rate, but in our country, fluoridization has not spread widely yet, so prevention has not been done satisfactorily. When dental caries progresses, irreversible damage of tooth structure occurs. In initial dental caries, demineralizing tooth structure can be remineralized, so restorative treatment is unnecessary. In this study, 20 teeth restored with composite resin without fluoride release were used and divided into two groups. Incipient dental caries were artificially made and demineralization procedure was done for 1 and 2 weeks, for each group. Changes in mineral contents around the margins were analysed with confocal laser scanning microscope. The results were as follow. 1. Both total fluorescence of the lesion and average fluorescence of the lesion of remineralized samples decreased compared to demineralizing state. (p<0.01) 2. Confocal laser scanning microscopy can be used in quantitative analysis of mineral change. In result, confocal laser scanning microscopy can be used in quantitative analysis of mineral change and it could be used in many different fields of dentistry in the future.

  • PDF

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

Extraction of Coastal Topography Using Terrestrial Laser Scanning Technique (지상 레이저 스캐닝 기법을 이용한 해안 지형 추출)

  • Lee, Jong-Chool;Lee, Yong-Hee;Mun, Du-Yeoul;Seo, Dong-Ju
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.435-438
    • /
    • 2007
  • A laser scanning technique has been attracting much attention as a new technology to acquire location information. This technique might be applicable to a wide range of areas, most notably in geomatics, due to its high accuracy of location and automation of high-density data acquisition. In this study, the coastline was extracted using laser scanning. Through this laser scanning technique, efficient change detection of coast section can be ensured and also they can provide important information to be used when detecting a coast section in the future.

  • PDF

Position Control of Laser Scanning Mirror Using Piezoelectric Actuator (압전작동기를 이용한 레이져 스케닝 미러의 위치제어)

  • 지학래;김재환;최승복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.442-445
    • /
    • 1995
  • This paper presents the position tracking control of a laser scanning mirror system in which piezoelectic actuator is incorporated. Using the shear mode of the piezoelectric actuator,angular oscillation of a laser scanning mirror is derived. Torsion bar is rhen designed and attached to the piezoelctric actuator in order to magnify the amplitude generated by the actuator. Finite element modeling and analysis are essntial for designing the piezoelectic actuator. The torsional resonance mode of the piezoelectric actuator is found from the model analysis of the actuator and the mechanical shear is matched with the driving frequency. Transfer function between the electrical excitation and the mechanical shear deformation at resonance frequency is found form the response of the actuator calculated by the finite element analysis and the governing equation of the system is derived from d'Alembert's principle. Tracking control performance for desired trajectory which is, in fact, sinusoidal curve is presented in order to demonstrate the validity of the proposed system.

  • PDF

Analysis of single/poly crystalline Si etching characteristics using $Ar^+$ ion laser ($Ar^+$ ion laser를 이용한 단결정/다결정 Si 식각 특성 분석)

  • Lee, Hyun-Ki;Park, Jung-Ho;Lee, Cheon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1001-1003
    • /
    • 1998
  • In this paper, $Ar^+$ ion laser etching process of single/poly crystalline silicon with $CCl_{2}F_{2}$ gas is studied for MEMS applications. To investigate the effects of process parameters, laser power, gas pressure, scanning speed were varied and multiple scanning was carried out to obtain high aspect ratio. In addition, scanning width was varied to observe the trench profile etched in repeating scanning cycle. From the etching of $2.6{\mu}m$ thick polycrystalline Si deposited on insulator, trench with flat bottom and vertical side wall was obtained and it is possible to apply this results for MEMS applications.

  • PDF

A Study on Transport Mechanism of the Ultrasonic Transporting System using Laser Scanning Vibrometer (Laser Scanning Vibrometer를 이용한 초음파 이송시스템의 이송 메커니즘에 관한 연구)

  • 정상화;신병수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.841-844
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. These systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the vibration behavior of flexural beam in the ultrasonic transport system is verified using Laser Scanning Vibrometer. The experiments for verifying vibration are performed in three conditions such as in the maximum transport speed, in the zero speed, and in the change of transport direction.

  • PDF