• 제목/요약/키워드: Scanning Image

검색결과 1,099건 처리시간 0.032초

A Study for a Near-Field Microwave Microscope Using a Tuning Fork Distance Control System in liquid Environment (튜닝폭 거리조절 센서를 이용한 근접장 마이크로파 현미경의 수중 측정을 위한 연구)

  • Kim, Song-Hui;Yoo, Hyung-Keun;Babajanyan, Arsen;Kim, Jong-Chul;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제27권4호
    • /
    • pp.345-353
    • /
    • 2007
  • We have obtained a topographical image nondestructively for a Cu thin film in liquid using a near-field scanning microwave microscope (NSMM), its operating frequency was 3.5 to 5.5 GHz. We have kept a distance of 10 nm between tip and sample using a quartz tuning fork shear force feedback system. As an end of tip was attached to one prong of the quartz tuning fork has a length of 2 mm, the only tip of tuning fork was immersed in water tank. A loss cause by evaporation in water tank is regulated with actuator was connected to a supplementary tank. Moreover, using a revise program of LabView, we could increase the accuracy of a measurement in liquid.

Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects (분화 갑상선 암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교)

  • Lee, Hong-Je;Lee, Sang-Woo;Song, Bong-Il;Kang, Sung-Min;Seo, Ji-Hyoung;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.129-136
    • /
    • 2009
  • Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer(DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients(M:F = 55:443, Age $47.6{\pm}12.9$ years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq(5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients(88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients(11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue(4 patients) and cervical lymph node metastasis(3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC.

The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT (PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구)

  • Do, Yong Ho;Song, Ho Jun;Lee, Hyung Jin;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Purpose : Presently, hardwares and softwares for reducing radiation exposure are continually developed for PET/CT examination. Purpose of this study is to evaluate effectiveness of reducing radiation exposure dose of CT and SUV changes of PET when applied each kernel to ACCT (Attenuation Correction Computed Tomography) according to adopted IRIS (Iterative Reconstruction in Image Space) software. Materials and Methods : Biograph mCT (Siemens, Germany) was used as a PET/CT scanner. Using AAPM CT performance phantom, from standard (120 kVp, 100 mAs), 7 scans were conducted by reducing 15 mAs each. After image reconstruction by FBP (Filtered Back Projection) and IRIS, noise and spatial resolution were evaluated. The same method was applied to anthropomorphic chest phantom and acquired images were compared. NEMA IEC body phantom was used for SUV evaluation. Injected dose rate for hot sphere (hot) and background cylinder (BKG) were 1:8. CT dose condition (120 kVp, 50 mAs) was the same for each scan and PET scan durations were 1, 2, 3 and 4min. After scanning, each kernel of IRIS was applied to ACCT. And PET images were reconstructed by ACCT adopted IRIS for comparing SUV changes. Results : AAPM phantom test for noise evaluation, SD for FBP 100 mAs, IRIS 55 mAs were 8.8 and 8.9. FBP 85 mAs, IRIS 40 mAs were 9.5 and 9.7. FBP 70 mAs, IRIS 25 mAs were 11.9 and 11.1. Above mAs condition for FBP and IRIS, SD showed similar values. And for spatial resolution test, there was no significant difference. For chest phantom test, when applied the same mAs and kernel to both of FBP and IRIS, every applied kernels showed reduced noise. Lower mAs and higher kernel value showed higher noise reduction. There was no considerable difference only except for I70 very sharp kernel for SUV comparison using NEMA IEC body phantom. Conclusion : In this study, low mAs (55 mAs) applied IRIS and standard mAs (100 mAs) applied FBP showed similar noise. And only except for I70 kernel, there was no significant SUV changes. It is possible to reduce needless radiation exposure and acquire better image quality than FBP's through applying appropriate kernel of IRIS to PET/CT.

  • PDF

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • 제5권2호
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • 제26권1호
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Freeze-thaw Resistance Estimation of Concrete using Surface Roughness and Image Analysis (콘크리트의 동결융해 저항성 추정을 위한 표면 거칠기 및 이미지 분석의 적용성)

  • Lee, Binna;Lee, Jong Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2018
  • As part of a research dedicated to the field evaluation of the durability of concrete subjected to freezing-thawing, this study analyzes the relationship between the surface roughness and the relative dynamic elastic modulus through image analysis. Four mix compositions with water-to-binder ratios (W/B) of 40%, 50%, 60% and 70% and without AE agent were considered to provoke early freezing. The basic physical properties of the mixes including the relative dynamic elastic modulus and the compressive strength were first evaluated experimentally according to W/B. Then, tests were performed to measure the surface roughness followed by photographs and SEM image analysis. The measured surface roughness tended to increase with larger number of freezing-thawing cycles regardless of W/B. The relative dynamic elastic modulus appeared to increase gradually with the number of cycles for the relatively denser mixes with W/B of 40% and 50%. Besides, the surface roughness increased only at rupture for the mixes with W/B of 60% and 70%. Moreover, the analysis of the photographs of the surface of the mixes with W/B of 40% and 50% revealed that the degradation progressed gradually from the surface with the freezing-thawing cycles. However, for the mixes with W/B of 60% and 70%, apparent change of the surface remained very insignificant until rupture at which damage like cracking could be observed. Consequently, the analysis of surface photograph or the measurement of the surface roughness presented some limitation in assessing the degree of freezing-thawing-induced degradation in case of relatively porous specimens. On the other hand, the photograph and surface roughness appeared to be sufficient for assessing such degradation for the mixes with W/B of 40% and 50%. Accordingly, the image of the surface and the surface roughness are potentially applicable on site for the assessment of freezing-thawing damages in relatively dense mixes.

Digital Hologram Compression Technique By Hybrid Video Coding (하이브리드 비디오 코팅에 의한 디지털 홀로그램 압축기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kang, Hoon-Jong;Lee, Seung-Hyun;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • 제42권5호
    • /
    • pp.29-40
    • /
    • 2005
  • According as base of digital hologram has been magnified, discussion of compression technology is expected as a international standard which defines the compression technique of 3D image and video has been progressed in form of 3DAV which is a part of MPEG. As we can identify in case of 3DAV, the coding technique has high possibility to be formed into the hybrid type which is a merged, refined, or mixid with the various previous technique. Therefore, we wish to present the relationship between various image/video coding techniques and digital hologram In this paper, we propose an efficient coding method of digital hologram using standard compression tools for video and image. At first, we convert fringe patterns into video data using a principle of CGH(Computer Generated Hologram), and then encode it. In this research, we propose a compression algorithm is made up of various method such as pre-processing for transform, local segmentation with global information of object image, frequency transform for coding, scanning to make fringe to video stream, classification of coefficients, and hybrid video coding. Finally the proposed hybrid compression algorithm is all of these methods. The tool for still image coding is JPEG2000, and the toots for video coding include various international compression algorithm such as MPEG-2, MPEG-4, and H.264 and various lossless compression algorithm. The proposed algorithm illustrated that it have better properties for reconstruction than the previous researches on far greater compression rate above from four times to eight times as much. Therefore we expect that the proposed technique for digital hologram coding is to be a good preceding research.

Radiation Dose Measurement for Bolus Tracking System with Brain CTDI Phantom in CT Scanning (CTDI 팬텀의 CT검사에서 볼루스 트래킹 시스템 적용을 위한 선량 측정)

  • Dae Cheol Kweon
    • Journal of the Korean Society of Radiology
    • /
    • 제18권7호
    • /
    • pp.881-887
    • /
    • 2024
  • The purpose of this study is to measure the dose according to tube voltage and tube current using a head CTDI phantom in a bolus tracking system for contrast agent injection in CT examination, evaluate the image with SNR, and use it as basic data for dose reduction according to CT examination. and can be applied. CT scans were performed on a head CTDI phantom by applying tube voltages of 80, 100, 120, and 140 kVp and tube currents of 10, 20, 30, 40, and 50 mA. The scan used a ROT of 0.5 sec and B30f kernel, and scanned at a thickness of 2.0 mm to measure dose, SNR, and noise. The dose results showed that as tube voltage and tube current increased, the phantom dose was at a minimum of 24.13 µGy at 80 kVp and 10 mA, and at a maximum of 407.28 µGy at 140 kVp and 50 mA, the dose increased 16.8 times. To evaluate image quality, the SNR of the phantom as tube voltage and tube current increased was as low as 2.3 at 80 kVp and 10 mA, and as high as 15.48 at 140 kVp and 50 mA, the SNR increased by 6.7 times the dose. Noise, which indicates image quality as a standard deviation in the image, was the lowest at 41.79 at 80 kVp, 10 mA, and the highest SNR was 7.94 at 140 kVp, 50 mA, and the dose was reduced by 81.35%. As various tube voltages and tube currents increased in CT scans, dose and SNR increased, but noise decreased. In conclusion, in order to apply the bolus tracking system, it can be applied to reduce dose by applying a combination of appropriate tube voltage and tube current to maintain image quality and reduce dose.

Motional kinematics of Frozen-thawed Korean native cattle semen use of computer aided semen analysis(CASA) system (컴퓨터 정액자동분석에 의한 동결융해 한우 정액의 운동특성 연구)

  • Lee, Kang-nam;Lee, Byeong-chun;Kim, Jung-tae;Park, Jong-im;Shin, Tae-young;Hwang, Woo-suk
    • Korean Journal of Veterinary Research
    • /
    • 제38권4호
    • /
    • pp.898-908
    • /
    • 1998
  • The aim of this experiments were to assess the time-interval change of motional characteristics in frozen-thawed semen of Korean native cattle (KNC) by using computer aided semen analysis (CASA) technology. Twenty-six KNC frozen semen straws were obtained from Korean KNC improvement department, livestock improvement main division, national livestock cooperatives federation in Korea. Specimens were allowed to thaw at $37^{\circ}C$ for 30 sec in water bath. Semen analysis was performed on semen image analysis system (SIAS, Medical supply, Korea) adjusted to the gate settings and used the semen droplet ($5{\mu}l$) placed on Makler counting chamber (Sefi medical instrument, Israel) prewarmed at $37^{\circ}C$. The same person used the same micropipette to fill the Makler counting chamber. A total of 150 or more of sperms were analysed in each specimen by a single trained person by scanning at least 5 to 10 fields. The measurement parameters in SIAS were as follows ; frame rate = 30 frames per sec, image capture = 1 sec, minimum motile speed = $10{\mu}m/s$, maximum countable sperm number = 400. Statistical analysis was done by Student t-test with use of the Sigma plot program on a IBM personal computer. The dancemean(DNM) and hyperactivated sperm(HYP) of frozen-thawed KNC semen kinematics were significantly decreased(p < 0.05) after 10 min of incubation at $37^{\circ}C$ water bath. But, wobble(WOB) of same sample semen was significantly increased(p < 0.05) after 10 min of incubation and significantly decrease(p < 0.05) after 60 min of same incubation. And, after 30 mim of incubation, significantly differences were found most of motion kinematics, motifity(MOT), curvilinear velocity(VCL), straight line velocity(VSL), average path velocity(VAP), amplitude of lateral head displacement(ALH), beat cross frequency(BCF), mean angular displacement(MAD), dance(DNC), on same sample semen. The DNM of KNC semen sample was variable kinematics after 30 min of incubation. Also, the linearity(LIN) and straightness(STR) was significantly decreased(p < 0.05) from 60 min of incubation. In conclusion, the AI within 30 min after thawing of frozen semen can be an effective method for obtaining high fertility rate in KNC reproductive program.

  • PDF

Design and Implementation of AR Model based Automatic Identification and Restoration Scheme for Line Scratches in Old Films (AR 모델 기반의 고전영화의 긁힘 손상의 자동 탐지 및 복원 시스템 설계와 구현)

  • Han, Ngoc-Soc;Kim, Seong-Whan
    • The KIPS Transactions:PartB
    • /
    • 제17B권1호
    • /
    • pp.47-54
    • /
    • 2010
  • Old archived film shows two major defects: line scratch and blobs. In this paper, we present a design and implementation of an automatic video restoration system for line scratches observed in archived film. We use autoregressive (AR) image model because we can make stochastic and specifically autoregressive image generation process with our PAST-PRESENT model and Sampling Pattern. We designed locality maximizing scanning pattern, which can generate nearly stationary time-like series of pixels, which is a strong requirement for a stochastic series to be autoregressive. The sampled pixel series undergoes filtering and model fitting using Durbin-Levinson algorithm before interpolation process. We designed three-stage film restoration system, which includes (1) film acquisition from VHS tapes, (2) simple line scratch detection and restoration, and (3) manual blob identification and sophisticated inpainting scheme. We implemented film acquisition and simple inpainting scheme on Texas Instruments DSP board TMS320DM642 EVM, and implemented our AR inpainting scheme on PC for sophisticated restoration. We experimented our scheme with two old Korean films: "Viva Freedom" and "Robot Tae-Kwon-V", and the experimental results show that our scheme improves Bertalmio's scheme for subjective quality (MOS), objective quality (PSNR), and especially restoration ratio (RR), which reflects how much similar to the manual inpainting results.