• Title/Summary/Keyword: Scanning Image

Search Result 1,093, Processing Time 0.029 seconds

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF

Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study (rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study)

  • Lee, Woo-Sung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man;Park, Yoon-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • Purpose: This preliminary rabbit study was conducted to evaluate the effect of recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/poly lactic-co-glycolic acid (PLGA) coating on osseointegration of the titanium (Ti) implant. Materials and methods: Eight Ti implants were anodized with 300 voltages for three minutes. Four of those were coated with rhTGF-${\beta}2$/PLGA by an electrospray method as the experimental group. The implants were placed into tibiae of four New Zealand rabbits, two implants per a tibia, one implant per each group. After 3 and 6 weeks, every two rabbits were sacrificed and micro-computed tomography (microCT) was taken for histomorphometric analysis. Results: In scanning electron microscope (SEM) image, the surface of rhTGF-${\beta}2$/PLGA coated Ti implant showed well distributed particles. Although statistically insignificant, microCT analysis showed that experimental group has higher bone volume / total volume (BV/TV) and trabecular thickness (Tb.Th) values relatively. Cross sectional view also showed more newly formed bone in the experimental group. Conclusion: In the limitation of this study, rhTGF-${\beta}2$/PLGA particles coating on the Ti implant show the possibility of more favorable quantity of newly formed bone after implant installation.

Fabrication and Evaluation Properties of Micro-Tubular Solid Oxide Fuel Cells (SOFCs) (마이크로 원통형 SOFC 제작 및 특성평가)

  • Kim, Hwan;Kim, Wan-Je;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.749-753
    • /
    • 2012
  • In present work, anode support for micro-tubular SOFC was fabricated with outer diameter of 3 mm and characterized with microstructure, mechanical properties and gas permeability. The microstructure of surface and cross section of a porous anode support were analyzed by using SEM (Scanning Electron Microscope) image. The gas permeability and the mechanical strength of anode support was measured and analysed by using differential pressure at the flow rates of 50, 100, 150 cc/min. and using universal testing machine respectively. The unit cell composed of NiO-YSZ, YSZ, YSZ-LSM/LSM/LSCF was fabricated and operated with reaction temperature and fuel flow rate and showed maximum power density of $1095mW/cm^2$ on the condition of $800^{\circ}C$. The performance of single cell for micro-tubular SOFC increased with the increasing the reaction temperature due to the decrement of ohmic resistance of cell by the increment of the ionic conductivity of electrolyte through the evaluation of electrochemical impedance analysis for single cell with reaction temperature.

A Framework for Digitalizing Handwritten Document using Digital Pen and Handwriting Recognition Technology (디지털펜과 필기체인식 기술을 이용한 수기문서 전자화 프레임워크)

  • Son, Bong-Ki;Kim, Hak-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1417-1426
    • /
    • 2011
  • Business still relies heavily on pen and paper for legal reasons or convenience. The handwritten document is to be converted into digitalized document for IT system to manage and process in real time. Because the previous document digitalization systems convert the handwritten documents into digitalized documents by scanning and post-processing the documents, it is difficult to seamlessly proceed the work process. This paper proposes the LiveForm, a framework for digitalizing handwritten document using digital pen and handwriting recognition technology. To prove the applicability of the proposed LiveForm, we also implement a LiveForm based service in industrial gas distribution process and analyze effects of the system. The LiveForm generates the same digital image as the handwritten document by writing up the paper with absolute coordinates by digital pen and converts the handwriting data to digital text to insert the information into back-end system. The LiveForm based system eliminates scanning for document digitalization and data input with keyboard into back-end system in paper-based information gathering. Therefore, it is possible for the LiveForm to improve work process in various business areas.

A Comparative Study on the Lens Dose According to the Change of Shielding Material Used in Brain Computed Tomography (Brain CT에서 차폐 재료 변화에 따른 수정체 선량 비교 연구)

  • Hwang, Incheol;Shin, Woonjae;Gang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • The cases of radiographic inspection for medical diagnosis in Korea have been continuously increasing year after year, which pays particularly more attention to CT which occupies over the half of medical radiation exposure. To find an effective alternative for reducing radiation exposure, the researchers conducted comparative experiments using some shields made of bismuth, aluminum 6mm, and silicone 22mm. These shielding materials have been used to reduce the entrance surface dose (ESD) on lenses, maintaining the CT number, noise, and uniformity in brain CT scanning which forms the largest part in CT scanning these days. These experiments showed that the doses in the spiral scan parallel to IOML and the conventional scan in Bismuth were 26.41% and 17.52%, respectively; in Aluminum 18.24% and 9.39%; in Silicone 19.47% and 14.39% lower than compared with those in the cases without any shields. In the items of the CT number, noise, and uniformity, the bismuth shield satisfied exceedingly the standards of the phantom image test while aluminum and silicone were within. To keep the graphic quality and get good shielding effect, we recommend the silicone shield which can be manufactured and purchased with ease.

Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning (Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석)

  • Chae, Deokho;Lee, Jangguen;Kim, Kwang-Yeom;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The mechanical characteristics of frozen sand greatly depend on the frozen temperature and the fine contents according to the previous study by Chae et al. (2015). There are two hypotheses to explain this experimental results; one is the unfrozen water contents greatly affected by the fine contents and frozen temperature and the other is the sand particle spacing greatly affected by the pore-ice. To evaluate the latter hypothesis, the micro X-ray CT scan was performed. The micro X-ray CT scanning, one of the actively performed interdisciplinary research area, has a high resolution with micrometer unit allows to investigate internal structure of soils. In this study, X-ray CT technique was applied to investigate the effect of the frozen temperature and fine contents on the sand particle minimum and average spacing with the developed image processing techniques. Based on the spacing analysis, the frozen temperature and fine contents have little influence on the sand particle spacing in the frozen sand specimens.

Effect of particle size of rice flour on popping rice bread (쌀가루 입도가 쌀 식빵의 팽화에 미치는 영향)

  • Park, Mi-Kyung;Kang, Soon-Ah;Lee, Kyung-Hee
    • Korean journal of food and cookery science
    • /
    • v.22 no.4 s.94
    • /
    • pp.419-427
    • /
    • 2006
  • The purpose of this study is to promote the substitution of rice flour for wheat flour in making bread and thus the consumption of rice by examining the effect of particle size of rice flour on leavening rice bread. For this purpose, several experiments were carried out. With regard to particle size distribution, 59.45% of wheat flour had passed 200 mesh and 3 kinds of rice flour milled to penetrate into 20, 35, and 45 mesh (S1, S2 and S3) had passed 21.88%, 33.1% and 36.38% of those for 200 mesh, respectively. To leaven the rice flour dough to bread, 25% of vital gluten was needed. To determine the optimal water quantity for rice bread dough, the hardness of wheat and rice flour dough was measured by rheometer. The appropriate water quantity for S1, S2 and S3 was set at 285 ml , 295 ml and 335${\sim}$340m1, respectively. The loaf volume index of the wheat flour bread was 6.24, while that of and rice flour bread S1, S2 and S3 was 5.38, 5.50 and 5.75, respectively. These results indicated that the loaf volume index of rice flour bread is lower than that of wheat flour bread, but that the volume of rice flour bread was increased with fuel particle size of rice flour. Scanning electron microscopy (SEM), image of the wheat bread tissue at a magnification of 35 times showed long, large, oval-shaped, air cells and thin cell membrane, as well as small air cells, whereas the images of rice flour showed angular, circular, air cells and rough and thick cell membrane. The size and number of air cells in the rice bread were larger in S2 and S3 with fuel particle flours than in S1. In particular, the bread made with S3 contained many air cells that were as large as those in the wheat bread were. In addition, when the inner cell wall was magnified 1500 times, almost no small air cell was observed in C and S3, whereas many fine air cells were observed in the cell wall of S1 and S2.

Surface Topography Measurement and Analysis for Bullet and Casing Signature Identification (총기 인식을 위한 측정 시스템 구현 및 해석 알고리즘 개발)

  • Rhee, Hyug-Gyo;Lee, Yun-Woo;Vorburger Theodore Vincent;Reneger Tomas Brian
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The Integrated Ballistics Identification Systems (IBIS) is widely used for bullet and casing signature identification. The IBIS obtains a pair of ballistic signatures from two bullets (or casings) using optical microscopy, and estimates a correlation score which can represent the degree of signature match. However, this method largely depends on lighting and surface conditions because optical image contrast is primarily a function of test surface's slope, shadowing, multiple reflections, optical properties, and illumination direction. Moreover, it can be affected with surface height variation. To overcome these problems and improve the identification system, we used well known surface topographic techniques, such as confocal microscopy and white-light scanning interferometry. The measuring instruments were calibrated by a NIST step height standard and verified by a NIST sinusoidal profile roughness standard and a commercial roughness standard. We also suggest a new analysis method for the ballistic identification. In this method, the maximum cross-correlation function CCFmax is used to quantify the degree of signature match. If the compared signatures were exactly the same, CCFmax would be $100\%$.

Enhanced Migration of Gasohol Fuels in Clay Soils and Sediments (Gasoline-ethanol(Gasohol)혼합액의 점토층 내 이동에 대한 연구)

  • Hee-Chul Choi;W.M. Stallard;Kwang-Soo Kim;In-Soo Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.67-79
    • /
    • 1996
  • Clay soils typically have low hydraulic conductivities in the presence of high polarity pore fluid, such as water. Low polarity fluids, such as hydrocarbon fuels and halogenated organic solvents, typically cannot migrate into clay pores because they cannot displace the pore water. Oxygenated additives in gasoline, such as alcohols and methyl-tert-butyl ether, are increasingly used to control air pollution emissions. These relatively polar and highly water-soluble compounds may facilitate displacement of pore water and enhance migration of fuels and solvents through clay-rich soil strata. In the reported research, the migration of gasoline-alcohol fuel mixtures (gasohol) through consolidated clay was examined. Prepared kaolinite clay samples were consolidated from slurry, and various combinations of gasoline, alcohol, and water were applied to the clays under 152 Pa gauge pressure. Movement of the fluids into the clay samples was monitored by measur ing displaced pore fluid and by magnetic resonance imaging of the samples. The structures of selected samples were examined using environmental scanning electron microscopy. Results of the research suggest that alcohol added to hydrocarbon fuels can enhance migration through some clays significantly. Gasoline did not migrate appreciably into water saturated clay, even after 14 days under pressure. The gasohol mixture migrated readily into the clay in only 20 minutes. Increased hydraulic conductivity of the clay in the presence of gasohol is hypothesized to be due to the collapse of the clays pore structure when ethanol is present, creating larger pores. Increasing pore diameter decreases the capillary pressure needed for the gasohol to replace water and allows gasohol to migrate through the clay.

  • PDF