• Title/Summary/Keyword: Scan velocity

Search Result 94, Processing Time 0.021 seconds

Ratio of Hammer Energy and Dynamic Efficiency of Standard Penetration Test (표준관입 시험 해머의 에너지비와 동적효율)

  • Lee, Chang-Ho;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.5-12
    • /
    • 2005
  • SPT hammer energy and its delivery are hon to influence the N value. The SPT hammer energy is classified into theoretical energy, velocity energy, rod energy and dynamic efficiency. In this study, the rod energy and the velocity energy are measured directly by PDA and Digital Line-Scan Camera which are most widely used type of SPT apparatus in Korea. The Dynamic efficiency is calculated through measured data. As the results of this study, the averages of rod energy ratio of donut, safety and automatic hammer are measured at 49.57, 61.60, and at $87.04\%$ by FV method. The averages of hammer velocity of donut, safety and automatic hammer are measured at $3.177{\pm}0.872$, $3.385{\pm}0.681$, and at $3.651{\pm}0.550$ m/s by Digital Line-Scan Camera, with the dynamic efficiencies at 0.732, 0.801, and 0.973 respectively.

Influence of Resin-Infiltrated Time on Wood Natural Materials Using Conventional/Air-Coupled Ultrasound Waves

  • Park, Je-Woong;Kim, Do-Jung;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David K.;Kim, Sun-Kyu;Yang, In-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • Composite wood materials are very sensitive to water and inspection without any coupling medium of a liquid is really needed to wood materials due to the permeation of coupling medium such as water. However, air-coupled ultrasound has obvious advantages over water-coupled experimentation compared with conventional C-scanner. In this work, it is desirable to perform contact-less nondestructive evaluation to assess wood material homogeneity. A wood material was nondestructively characterized with non-contact and contact modes to measure ultrasonic velocity using automated data acquisition software. We have utilized a proposed peak-delay measurement method. Also through transmission mode was performed because of the main limitation for air-coupled transducers, which is the acoustic impedance mismatch between most materials and air. The variation of ultrasonic velocity was found to be somewhat difference due to air-coupled limitations over conventional scan images. However, conventional C-scan images are well agreed with increasing the resin-infiltrated time as expected. Finally, we have developed a measurement system of an ultrasonic velocity based on data acquisition software for obtaining ultrasonic quantitative data for correlation with C-scan images.

The Study on Usefulness of the Standardized Information of Nuclear Medicine Scan in Function Evaluation of the Salivary Glands (침샘의 기능평가에서 핵의학 검사의 표준화된 정보제공의 유용성 연구)

  • Pyo, Sungjai;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.357-362
    • /
    • 2015
  • This study was to evaluate the usefulness through the comparison of patients group and healthy control group by acquiring a variety of functional parameters index from time-activity curves of salivary gland scan using 99mTc-pertechnetate. From December 2014 to February 2015, had the targets of 30 patients with dry mouth and 10 people in healthy control group underwent the salivary gland scan. After intravenous injection of 370 MBq of 99mTc-pertechnetate, Vitamin C powder stimulation was administerd orally at 20 min and then 10 minutes were taken scan. The method of quantitative analysis was as follows, the time-activity curve was drawn after the parotid gland and submandible gland were prescribed as a region of interest, a variety of function parameters index was obtained in each position of the curve, and the patients group and the control group were compared. As for the methods applied in comparison and measurement, uptake ratio (UR), time at maximum counts (Tmax), time at minimum counts (Tmin), maximum accumulation (MA), accumulation velocity, maximum secretion (MS), maximum stimulation secretion (MSS), and secretion velocity (SV) were used. In the comparison of functional parameters index of patient group and normal group, the healthy normal group showed significant difference compared to the patient group in all indices except for the minimum radioactivity time (Tmin), and also in terms of variation over time the normal group showed significant difference compared to the patient group (p<0.05). Consequently, it was considered that the quantitative analysis that used a variety of function parameters index would be useful for evaluating the function of the salivary glands of the patients with dry mouth as an objective and standardized information.

Detectability Measurement of GPR for Buried Target in Self-Designed Test Field (자체 제작한 시험장에서의 GPR의 매설물 검출능력에 관한 측정)

  • Son, Soo-Jung;Shin, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.322-328
    • /
    • 2000
  • In this paper, we were investigated the detectability on various specimen in self-designed test field using the GPR system with three antenna elements. The GPR system was constantly radiated 730MHz frequency. To examine the detectability on various condition, the test were experimented using different materials, size and buried depth. As an adjusted wave-propagation velocity, the location of hyperbolic curve pattern were displayed B-scan CRT. And the pattern was exactly positioned when it was compared to the real buried-depth. Therefore, we can confirm similarity between the wave-propagation velocity and previous results.

  • PDF

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Detection of High-Velocity Impact Damage in Composite Laminates Using PVDF Sensor Signals (고분자 압전 필름 센서를 이용한 복합재 적층판의 고속 충격 손상 탐지)

  • Kim Jin-Won;Kim In-Gul
    • Composites Research
    • /
    • v.18 no.6
    • /
    • pp.26-33
    • /
    • 2005
  • The mechanical properties of composite materials may severely degrade in the presence of damage. Especially, the high-velocity impact such as bird strike, a hailstorm, and a small piece of tire or stone during high taxing, can cause considerable damage to the structures and sub-system in spite of a very small mass. However, it is not easy to detect the damage in composite plates using a single technique or any conventional methods. In this paper, the PVDF(polyvinylidene fluoride) film sensors were used for monitoring high-velocity impact damage initiation and propagation in composite laminates. The WT(wavelet transform) and STFT(short time Fourier transform) are used to decompose the sensor signals. A ultrasonic C-scan and a digital microscope are also used to examine the extent of the damage in each case. This research shows how various sensing techniques, PVDF sensor in particular, can be used to characterize high-velocity impact damage in advanced composite.

The Wave Propagation in transversely isotropic composite laminates (가로 등방성 복합재료의 파동전파에 관한 연구)

  • Kim Hyung-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.422-425
    • /
    • 2005
  • In an transversely isotropic composite laminates, the velocities, the particle directions and the amplitudes of reflected and transmitted waves were obtained using the equation of motion, the constitutive equation, and the displacement equation expressed by wave number and frequency Eigenvalue problem involving a velocity was solved by Snell's law. Finally, the results were confirmed by T300 Carbon fiber/5208 Epoxy materials. This approach could be applied to the detection of flaws in a transversely isotropic composite laminates by the water immersion C-scan procedure.

  • PDF

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

The Wave Propagation in Transversely Isotropic Composite Laminates (가로 등방성 복합재료의 초음파에 관한 연구)

  • Kim Hyung-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.62-69
    • /
    • 2006
  • In transversely isotropic composite laminates, the velocities, the particle directions and the amplitudes of reflected and transmitted waves were obtained using the equation of motion, the constitutive equation, and the displacement equation expressed by wave number and frequency. Eigenvalue problem involving a velocity was solved by Snell's law. Finally, the results were confirmed by 7300 Carbon fiber/5208 Epoxy materials. This approach could be applied to the detection of flaws in transversely isotropic composite laminates by the water immersion C-scan procedure.

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.